Text
.
. [
o
- li '
E UNITED STATES Q
'i =i NUCLEAR REGULATORY COMMISSION l
[
WASHINGTON, D.C. 20555 4 001 P
SOUTHERN CALIFORNIA EDISON COMPANY SAN DIEGO GAS AND ELECTRIC COMPANY THE CITY OF RIVERSIDE. CALIFORNIA I
THE' CITY OF ANAHEIM. CALIFORNIA DOCKET NO. 50-361 SAN ONOFRE NUCLEAR GENERATING STATION. UNIT N0. 2 AMENDMENT TO FACILITY OPERATING LICENSE I
Amendment No.110 License No. NPF-10 t
1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Southern California Edison-Company, et al. (SCE or the licensee) dated April 7,1992, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended'(the Act), and the Commission's y
regulations set forth in 10 CFR Chapter I B.
The facility will operate in conformity with the application,-the-provisions of the Act, and the rules and regulations of the Commission;
~
~
C.
There is reasonable assurance ~(1) th'at the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will-be -
i conducted in compliance with the Commission's regulations; D.
The issuance of-this amendment will not be inimical to the common-a defense and security or to the health and safety of: the public;-
and-i E.
The issuance of this amendment is;in accordance with 10 CFR I
Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
t
- t t
9402140154 940204 PDR ADOCK 05000361
)
P.:
- , 2.
Accordingly, the license is amended by changes to the Technical Speci-fications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of facility Operating License No. NPF-10 is hereby amended to read as follows:
(2)
Igchnical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised -
through Amendment No.110, are hereby incorporated in the license. Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
3.
This license amendment is effective as of the date of its issuance and must be fully implemented no later than 30 days from the date of issuance.
t FOR THE NUCLEAR REGULATORY COMMISSION
,(/.;La
//c y
Theodore R. Quay, Director.
Project Directorate V Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: February 4, 1994 l
i
ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO.110TO FACILITY OPERATING LICENSE N0. NPF-IO DOCKET NO. 50-361 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the enclosed pages. The revised pages are identified by the captioned amendment number and contain marginal lines indicating the areas of change. The corresponding overleaf pages are also provided to maintain document completeness.
REMOVE INSERT 3/4 3-15 3/4 3-15 3/4 3-23 3/4 3-23 3/4 3-27 3/4 3-27 3/4 3-31 3/4 3-31 l
e 1
TABLE 3.3-3 (Continued)
]
ENGINEERED SAFETY FEATURES ACTUATION SYSTEN INSTRUMENTATION 8n MINIMUM A
TOTAL NO.
CHANNELS CHANNELS APPLICABLE e
FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION 4.
MAIN STEAM LINE ISOLATION a.
Manual (Trip 2/ steam 1/ steam 2/ operating 1, 2, 3 11 Buttons) generator generator steam generator b.
Steam Generator 4/ steam 2/ steam 3/ steam 1, 2, 3 9*,
10*
Pressure - Low generator generator generator c.
Automatic Actuation 4/ steam 2/ steam 3/ steam 1, 2, 3 9*,
10*
Logic generator generator generator w
5.
RECIRCULATION (RAS) a.
Refueling Water Storage Tank - Low 4
2 3
1, 2, 3, 4 9*,
10*
b.
Automatic Actuation Logic 4
2 3
1, 2, 3, ' 4 9*,
10*
6.
CONTAINMENT COOLING (CCAS) 2.
Manual CCAS (Trip Buttons) 2 sets of 2 I set of 2 2 sets of 2 1,2,3,4 8
il b.
Delet9<f intentionally 3
E!
c.
' Automatic Actuation Logic 4
2 3
1, 2, 3, 4 9*,
10*
5 O
TABLE 3.3-3 (Continued)
ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION O53 MINIMUM TOTAL NO.
CHANNELS CHANNELS APPLICABLE FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION Z
7.
LOSS OF POWER (LOV)
~
a.
4.16 kV Emergency Bus Undervoltage (Loss of Voltage and Degraded Voltage) 4/ Bus 2/ Bus 3/ Bus 1, 2, 3, 4 9 *, 10
- 8.
Manual (Trip Buttons) 2 sets of 2 I set of 2 2 sets of 2 1, 2, 3 11
{
per S/G per S/G per S/G i'
b.
Automatic Actuation Z
logic 4/SG 2/SG 3/SG 1, 2, 3 9*, 10*
c.
SG Level (A/B) - Low and AP (A/B) - High 4/SG 2/SG 3/SG 1, 2, 3 9*, 10*
d.
SG Level (A/B) - Low and No S/G Pressure -
Low Trip (A/B) 4/SG 2/SG 3/SG 1, 2, 3 9*,
10*
e y
n v
w
TABLE 3.3-4 (Continuedl ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION TRIP VALUES
@?
- o ALLOWABLE FUNCTIONAL UNIT TRIP YAlW, VALUES 6.
CONTAINMENT COOLING (CCAS)
~
a.
Manual CCAS (Trip Buttons)
Not Applicable Not Applicable b.
deleted intentionally c.
Automatic S:tuation logic Not Applicable Not Applicable 7.
LOSS OF POWER (LOV)
-4.16 kv Emergency Bus Undervoltage a.
2 (Loss of Voltage and Degraded Voltage)
See Fig. 3.3-1 (4)
See Fig. 3.3-1 (4) 8.
EMERGENCY FEEUV'.TER (EFAS) a.
Manual (Trip Buttons)
Not Applicable Not Applicable b.
Steam Generator (A&B) Level-Low 2 21% (3) 2 20% (3) c.
Steam Generator AP-High (SG-A > SG-B)
$ 125 psi s 140 psi d.
Steam Generator AP-High (SG-B > SC 4) s 125 psi s 140 psi e.
Steam Generator (A&B) Pressure -
2 741 psia (2) 2 729 psia (2) 3Eg f.
Automatic Actuation logic Not Applicable Not Applicable 39 5
~
P BLE 3.3-4 (Continued) tiiC!urrPr0 SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION TRIP VALUES
=%5 ALLOWABLE f1NCTIONAl UNIT TRIP VALUE VALUES._
i 9.
CONTROL ROOM ISOLATION (CRIS) a.
Maual CRIS (Trip Buttons)
Not Applicable Not Applicable b.
Manual SIAS (Trip Buttons)
Not Applicable Not Applicable c.
-Airborne Radiation 1.
Particulate / Iodine s S.7 x 10' cpm **
s 6.0 x 10' cpm **
2
- 11. Gaseous s 3.8 x 10* cpm **
s 4.0 x 10 cpm **
w d.
Automatic Actuation Logic Not Applicable Not Applicable
- 10. T0XIC GAS ISOLATION (TGIS) a.
Manual (Trip i;uttons)
Not Applicable Not Applicable b.
Chlorine - High s 14.3 ppm s 15.0 ppm c.
Amonia - High s 97 ppm s 100 ppm d.
Butane / Propane - High s 193 ppm s 200 ppm e.
Automatic Actuation Logic Not Applicable Not Applicable h
E 5
e e.-
e r
- +
sw -
,e n
n.
TABLE 3.3-5 ENGINEERED SAFETY FEATURES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION RESPONSE TIME (SEC) l.
Manual a.
SIAS Safety injection Not Applicable Control Room Isolation Not Applicable Containment Isolation (3)
Not Applicable i
b.
CSAS Containment Spray Not Applicable c.
CIAS Containment Isolation Not Applicable d.
MSIS Main Steam Isolation Not Applicable e.
RAS Containment Sump Recirculation Not Applicable f.
CCAS Containment Emergency Cooling Not Applicable 9
EFAS Auxiliary Feedwater Not Applicable h.
CRIS Control Room Isolation Not Applicable i.
TGIS Toxic Gas Isolation Not Applicable J.
FHIS Fuel Handling Building Isolation Not Applicable k.
CPIS Containment Purge Isolation Not Applicable SAN ONOFRE-UNIT 2 3/4 3-27 AMENDMENT NO. 110
(
Table 3.3-5'(cCntinued)
INITIATING SIGNAL AND FUNCTION RESPONSE TIME (SEC) 2.
Pressurizer Pressure-Low a.
SIAS (1) Safety Injection (a)
High Pressure Safety Injection 31.2*
(b)
Low Pressure Safety Injection 41.2*
(c)
Charging Pumps 31.2*
(2) Control Room Isolation Not Applicable (3) Containment Isolation (NOTE 3) 11.2* (NOTE 2)
(4) Containment Spray (Pumps) 25.6*
(5)
Containment Emergency Cooling (a)
CCW Pumps 31.2*
(b)
CCW Valves (Note 4b) 23.2*
i (c)
Emergency Cooling Fans 21.2*
3.
Containment Pressure-Hioh a.
SIAS (1) Safety Injection (a)
High Pressure Safety Injection 41.0*
(b)
Low Pressure Safety Injection 41.0*
(2) Control Room Isolation Not Applicable (3) Containment Spray (Pumps) 25.4*
(4)
Containment Emergency Cooling (a)
CCW Pumps 31.0*
(b)
CCW Valves (Note 4b) 23.0*
(c)
Emergency Cooling Fans 21.0*
b.
CIAS (1) Containment Isolation 10 i* (NOTE 2)
(2) Hsin Feedwater Isolation 10.9 and Backup Isolation Valves (HV 4048, HV 4052, HV 1105, HV 1106, HV 4047, HV 4051)
(3) CCW Valves (Note 4a) 20.9 (4) Mainsteam Isolation Valves (H7.204, 8.9 HV 8205)
(5) Minipurge Isolation Valves 5.9 4.
Containment Pressure - Hich-Hioh CSAS Containm?nt Spray 23.0*
SAN ONOFRE-UNIT 2 3/4 3-28 AMENDMENT NO. 64
TABLE 4.3-2 ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION SURVEILLANCE REQUIREMENTS h
CHANNEL MODES FOR WHICH g
CHANNEL CHANNEL FUNCTIONAL SURVEILLANCE 7
FUNCTIONAL UNIT CHECK CALIBRATION TEST IS REQUIRED E
1.
SAFETY INJECTION (SIAS)
Z a.
Manual (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3, 4 b.
Containment Pressure - High S
(6)
Q 1, 2, 3 m
c.
Pressurizer Pressure - Low S
(6)
Q 1, 2, 3, d.
Automatic Actuation Logic N.A.
N.A.
Q(3), SA(4) 1, 2, 3, 4 CONTAINMENT SPRAY (CSAS) e.
a.
. Manual (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3 b.
Containment Pressure --
High - High 5
(C Q
1, 2, 3 c.
-Automatic Actuation Logic N.A.
N.A.
Q(3), SA(4) 1, 2, 3 N
3.
CONTAINMENT ISOLATION (CIAS)
Y a.
Manual CIAS (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3, 4 b.
Manual SIAS (Trip Buttons)(5)
N.A.
N.A.
(6) 1, 2, 3, 4 c.
Containment Pressure - High 5
(6)
Q 1, 2, 3 d.
Automatic Actuation logic N.A.
N.A.
Q(3), SA(4) 1, 2, 3, 4 4.
MAIN STEAM ISOLATION (MSIS) a.
Manual (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3 b.
Steam Generator Pressure - Low S
(6)
Q I, 2, 3 c.
Automatic Actuation Logic H.A.
N.A.
Q(3),SA(4) 1, 2, 3 5.
RECIRCULATION (RAS) a.
Refueling Water Storage k
Tank - Low S
R Q
1, 2, 3, 4 g
b.
Automatic Actuation logic N.A.
N.A.
Q(3),SA(4) 1, 2, 3, 4 5
6.
CONTAINMENT COOLING (CCAS) z a.
Hanual CCAS (Trip Buttons)
N.A.
H.A.
(6) 1, 2, 3, 4 o
b.
deleted intentionally l
c.
Automatic Actuation Logic N.A.
N.A.
Q(3), SA(4) 1, 2, 3, 4
_ TABLE 4.3-2 (Continued)
ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION SURVEILLANCE RE_QUIREMENTS-3 E
CHANNEL MODES FOR WHICH CHANNEL CHANNEL FUNCTIONAL SURVEILLANCE 7
FUNCTIONAL UNIT CHECK CALIBRATION TEST IS REQUIRED l
E U
7.
LOSS OF POWER (LOV) w a.
4.16 kV Emergency Bus t
Undervo.1tage (Loss of Voltage and Degraded Voltage)
S (6)
(6) 1, 2, 3, 4 8.
Manual (Trip Buttons)
N.A.
N.A.
(6)
I, 2, 3, b.
SG Level'(A/B)-Low and AP (A/B) - High 5
(6)
~ Q
_ I, 2,.3 2
c.
SG Level (A/B) - Low-and No Pressure - Low Trip (A/B)
S (6)
Q 1, 2, 3 y;,
d.
Automatic Actuation Logic N.A.
M.A.
Q(3) SA(4) 1, 2, 3.
4 m
9.
CONTROL ROOM ISOLATION (CRIS) a.
Manual CRIS (Trip Buttons)
N.A.
N.A.
R N.A.
b.
Man' sal'SIAS (Trip Buttons)
N.A.
N.A.
R N.A.
c.
Airborne Radiation.
- 1.
Particulate / lodine-S R
M All
- 11. Gaseous S
R M
All
~d.
Automatic Actuation logic N.A.
M.A.
R(3)
All
- 10. T0XIC GAS ISOLATION (TGIS) a.
Manual (Trip Buttons)
N.A.
N.A.
R M.A.
=
b.
Chlorine - High S
R M
All 3
c.
Ansonia - High
~3 d.
Butane / Propane - High.
5 R
M All S
R M
All e.
Automatic Actuation Logic M.A.
M.A.
R(3)
- All w
- wa w -,
+-w..e w
e, w +
-ce
---w
= w w-
-- w w - v, w y we v
, w e-um -- m e =w a w, o r e -s 4
=*1e g
=3 as-
~c+--
w-
- 4.~-~%se-i-www--wy gs 4,-
-v,>
v b e-
- po s c <,y'o,
[t
[k UNITED STATES I
i(
Q--
P WASHINGTON, D.C. 20555-0001 NUCLEAR REGULATORY COMMISSION SOUTHERN CALIFORNIA EDISON COMPANY j
SAN DIEGO GAS AND ELECTRIC COMPANY THE CITY OF RIVERSIDE. CALIFORNIA THE CITY OF ANAHEIM. CALIFORNIA i
DOCKET N0. 50-362 SAN ONOFRE NUCLEAR GENERATING STATIOL (! NIT NO. 3 f
AMENDMENT TO FACILITY OPERATING LICENSE 1
Amendment No. 99 License No. NPF-15 1.
The Nuclear Regulatory Comission (the Commission) has found that:
A.
The application for amendment by Southern California Edison Company, et isl. (SCE or the licensee) dated April 7,1992, complies with the standards and requirements of'the Atomic Energy Act of 1954, as amended (the Act), and the Commission's regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of-the public and
)
E.
The issuance of this amendment is in accordance with 10 CFR i
Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
l l
'k, 2-2.
Accordingly, the license is amended by changes to the Technical Speci-fications as indicated in the attachment to this license amendment, and paragraph 2.C(2) of facility Operating License No. NPF-15 is hereby amended to read as follows:
(2)
Technical Specificat.42n1 The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No. 99 are hereby incorporated in the license.
Southern California Edison Company shall operate the facility in accordance with the Technical Specifications and.the Environmental Protection Plan.
3.
This license amendment is effective as of the date of its issuance and must be fully implemented no later than 30 days from the date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION 9
s
^
, ;'jgs :L a 9u ~~ '^ y Theodore R. Quay, Director Project Directorate V Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: February 4, 1994 5
9 ATTACHMENT TO LICENSE AMENDMENT AMENDMENT NO. 99 TO FACILITY OPERATING LICENSE NO. NPF-15 DOCKET NO. 50-362 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the enclosed pages. The revised pages are identified by the captioned amendment number and contain marginal lines indicating the areas of change. The corresponding overleaf pages are also provided to maintain document completeness.
REMOVE INSERT 3/4 3-15 3/4 3-15 3/4 3-23 3/4 3-23 3/4 3-27 3/4 3-27 3/4 3-31 3/4 3-31 i
I
+
t
TABLE 3.3-3 (Continued)
ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION o52 MINIMUM TOTAL NO.
CHANNELS CHANNELS APPllCABLE FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION E
4.
MAIN STEAM tlNE ISOLATION w
a.
Manual (Trip 2/ steam 1/ steam 2/ operating 1, 2, 3 11 Buttons) generator generator steam generator b.
Steam Generator 4/ steam 2/ steam 3/ steam I, 2, 3 9*,
10*
Pressure - Low generator generator generator c.
Automatic Actuation 4/ steam 2/ steam 3/ steam I, 2, 3 9*,
10*
logic generator generator generator 1
5.
RECIRCULATION (RAS)
.G a.
Refueling Water Storage Tank - Low 4
2 3
1, 2, 3, 4 9*,
10*
b.
Automatic Actuation Logic 4
2 3
1,2,3,4 9*,
10*
6.
CONTA!NMENT COOLING (CCAS) a.
Manual CCAS (Trip Buttons) 2 sets of 2 1 set of 2 2 sets of 2 1, 2, 3, 4 8
3Eg b.
Deleted intentionally 8
m c.
Automatic Actuation "i
Logic 4
2 3
1, 2, 3, 4 9*,
10*
5
Y TABt.E 3.3-3 (Continued) z ENGINEERED SAFETY FEATURE'; AtlUATION SYSTEM INSTRUMENTATION o52 m
MINIMUM TOTAL NO.
CHANNELS CHANNELS APPLICABLE g
FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION U
7.
LOSS OF POWER (LOV) w a.
4.16 kV Emergency Bus Undervoltage (Loss of Voltage and Degraded Voltage) 4/ Bus 2/ Bus 3/ Bus 1, 2, 3, 4 9*,
10*
8.
EMERGENCY FEE 0 WATER (EFAS) w a.
Manual (Trip Buttons) 2 sets of 2 1 set of 2-2 sets of 2 1, 2, 3 11 s^
per S/G per S/G per S/G
-h b.
Automatic Actuation Logic 4/SG 2/SG 3/SG 1, 2, 3 9*,
10*
c.
SG Level (A/B) - Low l
and AP.(A/B) - High 4/SG 2/SG
_ 3/SG 1, 2, 3 9*,
10*
d.
SG Level (A/B) - Low and No S/G Pressure -
Low Trip (A/B) 4/SG 2/SG 3/SG 1, 2, 3 9*,
10*
l l
t r
---m
,e
< ~
TABLE 3.3-4'(Continued).
Y
~
E ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION TRIP VALUES z
m ALLOWABLE FUNCTIONAL UNIT TRIP VALUE VALUES 6.
CONTAINMENT COOLING (CCAS).
i w
a.
Manual CCAS (Trip Buttons)
Not Applicable Not Applicable b.
deleted intentionally l
c.
Automatic Actuation Logic Not Applicable Not Applicable 7.
LOSS OF POWER (LOY) a.
4.16 kV Emergency Bus Undervoltage w1 (Loss of Voltage-and Degraded Voltage)
See Fig. 3.3-1 (4)
See Fig. 3.3-1 (4) 8.
Manual (Trip Buttons)
Not Applicable-Not Applicable b.
Steam Generator (A&B) level-Low 2 21% (3) 2 20% (3) c.
' Steam Generator AP-High (SG-A > SG-B)
. s 12S psi s 140 psi d.
Steam Generator AP-High (SG-B > SG-A) s 125 psi s 140 psi e.
Steam Generator (A&B)-Pressure - Low-2 741 psia-(2) 2 729 psia (2)
N
- g f.
Automatic' Actuation logic Not Applicable Not Applicable
-3 E
- 5 e
a.-
.-s-
-m
- -. - - - - - ~ -
e,e a ww
.--w4 e
w-e ea +v e -
w
-wr s
TABLE 3.3-4 (Continued) u, E
ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION TRIP VALUES 9
om
- o ALLOWABLE 7
FUNCTIONAL UNIT TRIP VALUE VALUES E
9.
CONTROL ROOM ISOLATION.(CRIS)
- a. - Manual CRIS (Trip Buttons)
Not Applicable Not Applicable w
b.
Manual SIAS (Trip Buttons)
Not Applicable Not Applicable c.
Airborne Radiation 1.
Particulate /Icdine s 5.7 x 10' cpm **
s 6.0 x 10' cpm **
- 11. Gasecus s 3.8 x 10' cpm **
s 4.0 x 10' cpm **
'1 d.
Automatic Actuation-Logic Not Applicable Not Applicable
- 10. ;T0XIC GAS ISOLATION (TGIS) a.
Manual-(Trip' Buttons)
Not Applicable Not Applicable b.
Chlorine - High 5 14.3 ppm.
-s 15.0 ppe c.
hunonia - High s 97 ppe
$ 100 ppe d.
Butane / Propane - High.
s 193 ppe s 200 ppe g-e.
Automatic Actuation Logic.
Not Applicable
- Not Applicable 5-s t
G -
.....-,q.
..-e s
1,*--
..,-v v-.---
U-m--,
m
++-
-,. - +_- -
m
. m m
.i i
j TABLE 3.3-5 ENGINEERED SAFETY FEATURES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION RESPONSE TIME (SEC) 1.
Manual a.
SIAS j
i Safety Injection Not Applicable Control Room Isolation Not Applicable Containment Isolation (3)
Not Applicable g
b.
CSAS 1
Containment Spray Not Applicable c.
CIAS 1
Containment Isolation Not Applicable d.
MSIS Main Steam Isolation Not Applicable e.
RAS Containment Sump Recirculation Not Applicable f.
CCAS Containment Emergency Cooling Not Applicable 9
EFAS Auxiliary Feedwater Not Applicable h.
CRIS Control Room Isolation Not Applicable i.
TGIS Toxic Gas Isolation Not Applicable 4
FHIS Fuel Handling Building Isolation Not Applicable i
k.
CPIS Containment Purge Isolation Not Applicable SAN ONOFRE - UNIT 3 3/4 3-27 AMENDMENT-NO. 99
Table 3.3-5 (continued)
INITIATING SIGNAL AND FUNCTION RESPONSE TIME (SEC) 2.
Pressurizer Pressure-tow SIAS (1)
Safety Injection (a) High Pressure Safety injection 31.2*
(b)
Low Pressure Safety injection 41'.2*
(c) Charging Pumps 31.2*
(2)
Control Room Isolation Not Applicable (3)
Containment Isolation (NOTE 3) 11.2* (NOTE 2)
(4)
Containment Spray (Pumps) 25.6*
(5)
Containment Emergency Cooling (a) CCW Pumps 31.2*
(b) CCW Valves (NOTE 4b) 23.2*
(c)
Emergency Cooling Fans 21.2*
3.
Containment Pressure-Hiah a.
SIAS (1)
Safety Injection (a) High Pressere Safety Injection 41.0*
(b)
Low Pressure Safety Injection 41.0*
(2)
Control Room Isolation Not Applicable (3)
Containment Spray (Pumps) 25.4*
(4)
Containment Emergency Cooling (a) CCW Pumps 31.0*
(b) CCW Valves (NOTE 4b) 23.0*
(c)
Emergency Cooling Fans 21.0*
b.
CIAS (1)
Containment Isolation 10.9* (NOTE 2)
(2)
Main Feedwater Backup Isolation 10.9 and Backup Isolation Valves (HV 4048, HV 4052, HV 1105, HV 1106, HV 4047, HV 4051)
(3)
CCW Valves (Note (a) 20.9 (4)
Mainsteam Isolation Valves (HV 8204, 8.9 HV 8205)
(5)
Minipurge Isolation Yalves 5.9 4.
Containment Pressure - Hich-Hioh CSAS Containment Spray 23.0*
SAN ONOFRE - UNIT 3 3/4 3-28 AMENDMENT NO. 53
TABLE 4.3-2 ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUNENTATION SURVEILLANCE REQUIREMENTS o
k CHANNEL MODES FOR WHICH A
CHANNEL CHANNEL FUNCTIONAL SURVEILLANCE FUNCTIONAL UNIT CHECK CALIBRATION TEST IS REQUIRED 1.
SAFETY INJECTION (SIAS) a.
Manual (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3, 4 w
b.
Containment Pressure - High S
(6)
Q I, 2, 3 c.
Pressurizer Pressure - Low S
(6)
Q 1, 2, 3 d.
Automatic Actuation Logic N.A.
N.A.
Q(1)(3),SA(4) 1, 2, 3, 4 2.
CONTAINMENT SPRAY (CSAS) a.
Manual (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3 b.
Containment Pressure --
High - High S
(6)
Q 1, 2, 3 c.
Automatic Actuation Logic N.A.
N.A.
Q(1)(3), SA(4) 1, 2, 3 m1 3.
CONTAINMENT ISOLATION (CIAS) m L,
a.
Manual CIAS (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3, 4 b.
Manual SIAS (Trip Buttons)(S)
N.A.
N.A.
(6) 1, 2, 3, 4 c.
Containment Pressure - High 5
(6)
Q 1, 2, 3 d.
Automatic Actuation logic N.A.
N.A.
Q(1)(3), SA(4) 1, 2, 3, 4 4.
MAIN STEAM ISOLATION (MSIS) a.
Manual (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3 b.
Steam Generator Pressure - Low S (6)
Q 1, 2, 3 c.
Automatic Actuation Logic N.A.
N.A.
Q(1)(3),SA(4) 1, 2, 3 S.
RECIRCULATION (RAS) g a.
Refueling Water Storage g
Tank - Low S
R Q
1, 2, 3, 4 g
b.
Automatic Actuation Logic N.A.
N.A.
Q(1)(3),SA(4) 1, 2, 3, 4 E
H 6.
CONTAINMENT COOLING (CCAS) g a.
Manual CCAS (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3, 4 b.
& eted intentionally l
c.
Automatic Actuation Logic N.A.
N.A.
Q(1)(3),SA(4) 1, 2, 3, 4 h
e 2
TABLE 4.3-2 (Continued) gj ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION SURVEILLANCE REQUIREMENTS SE CHANNEL MODES FOR WHICH SR CHANNEL CHANNEL FUNCTIONAL SURVEILLANCE p(
FUNCTIONAL UNIT
_ CHECK CAllBRATION TEST IS REQUIRED
!k 7.
LOSS OF POWER (LOV)
-d a.
4.16 kV Emergency Bus Undervoltage (Loss of Voltage and Degraded Voltage)
S (6)
(6) 1, 2, 3, 4 B.
Manual (Trip Buttons)
N.A.
N.A.
(6) 1, 2, 3 b.
SG Level (A/B)-Low and AP (A/B) - High S
(6)
Q 1, 2, 3 c.
SG Level (A/B) - Low and No u,
1:
Pressure - Low Trip (A/B)
S (6)
Q 1, 2, 3 d.
Automatic Actuation logic N.A.
N.A.
Q(3) SA(4) 1, 2, 3 u,
9.
CONTROL ROOM ISOLATION (CRIS) a.
Manual CRIS (Trip Buttons)
N.A.
N.A.
R N.A.
b.
Manual SIAS (Trip Buttons)
N.A.
N.A.
R N.A.
c.
Airborne Radiation i
1.
Particulate / Iodine S
R M
All it.-Gaseous S
R M
All d.
Automatic Actuation Logic N.A.
N.A.
R(3)
All
- 10. T0XIC GAS ISOLATION (TGIS)
I a.
Manual (Trip Buttons)
N.A.
N.A.
R N.A.
I 3;
b.
Chlorine - High S
R M
All g
c.
Amonia - High S
R M
All 5!
d.
Butane / Propane - High S
R H
All gg e.
Automatic Actuation Logic N.A.
N.A.
R(3)
All
-a E
__._______,-2_
m