August 19, 1993 Docket No. 50-313 Mr. Jerry W. Yelverton Vice President, Operations ANO Entergy Operations, Inc.
Route 3 Box 137G Russellville, Arkansas 72801
Dear Mr. Yelverton:
SUBJECT:
SAFETY EVALUATION OF RESPONSE TO GENERIC LETTER 87-02 ARKANSAS NUCLEAR ONE, UNIT NO. I (TAC NO. M69426)
The NRC staff has concluded its review of the licensee's response to Generic Letter (GL) 87-02, Supplement No. 1.
Based on our revie-of the licensee's response and the staff positions delineated in Supplement No. I to GL 87-02, the staff concludes that the licensee's response is adequate and acceptable and that the floor response spectra (FRS) included in the plant Safety Analysis Report, as supplemented by additional FRS curves given in Attachment I to the licensee's letter of September 18, 1992, may be used for ihe resolution of Unresolved Safety Issue A-46.
In view of the procedures used in developing the FRS as expiained in the enclosed safety evaluation, the staff considers the FRS to be " median-centered," rather than " conservative design" FRS, as defined in Supplement No. 1 to GL 87-02.
The staff's Safety Evaluation is enclosed.
Sincerely, ORIGINAL SIGNED BY:
Roby B. Bevan, Project Manager Project Directorate IV-1 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/ enclosure:
See next page DJSTRIBUTION:
Docket File NRC & Local PDRs PD4-1 Reading J. Roe E. Adensam H. Rood P. Noonan R. Bevan 0GC ACRS (10) (P-315)
A. B. Beach 0FC LA:PD4rlyl PM : P.04.--I D(A):PD4-1 b
Rbv$n$pk HRood b NAME PNoonan DATE Y$/M/93 V/$/93 W/O/93 COPY YE5f 0 )
YES/NO YES/NO 0FFICIAL RECORD COPY Document Name: AR169426169426ltr l
b hhh h y
93090B0061 930819 L
PDR ADDCK 05000313 P
PDR,
1 August 19 1993 0
Docket No. 50-313 1,A Mr. Jerry W. Yelverton i
Vice President, Operations ANO j
Entergy Operations, Inc.
Route 3 Box 137G Russellville, Arkansas 72801
Dear Mr. Yelverton:
SUBJECT:
SAFETY EVALUATION OF RESPONSE TO GENERIC LETTER 87-02 ARKANSAS NUCLEAR ONE, UNIT N0. 1 (TAC NO. M69426) l The NRC staff has concluded its review of the licensee's response to Generic Letter (GL) 87-02, Supplement No. 1.
Based on our review of the licensee's response and the staff positions delineated in Supplement No. I to GL 87-02, the staff concludes that the licensee's response is adequate and acceptable and that the floor response spectra (FRS) included in the plant Safety i
Analysis Report, as supplemented by additional FRS curves given in Attachment I to the licensee's letter of September 18, 1992, may be used for the resolution of Unresolved Safety Issue A-46.
I In view of the procedures used in developing the FRS as explained in the enclosed safety evaluation, the staff considers the FRS to be " median-centered," rather than " conservative design" FRS, as defined in Supplement l
No. I to GL 87-02.
The staff's Safety Evaluation is enclosed.
1 Sincerely, ORIGINAL SIGNED BY:
Roby B. Bevan, Project Manager Project Directorate IV-1 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/ enclosure:
See next page DISTRIBUTION:
Docket File NRC & Local PDRs PD4-1 Reading J. Roe E. Adensam H. Rood P. Noonan.
R. Bevan OGC ACRS (10) (P-315)
A. B. Beach 0FC LA:PD4 M d PM PJ)4.-l D(A):PD4-1 NAME PNoona [ I RNv$n$pk HRood b DATE E//l/93 V / N/93 W/6/93 COPY YES60';
YES/NO YES/NO 0FFICIAL RECORD COPY Document Name: AR169426169426ltr
- t UNITED STATES
[ t 4 2.;[' j NUCLEAR REGULATORY COMMISSION 1
I WASHINGTON. D C. 20555-0001 h,
c o
August 19, 1993 Docket No. 50-313 Mr. Jerry W. Yelverton Vice Prasident, Operations ANO Entergy Operations, Inc.
Route 3 Box 137G Russellville, Arkansas 72801
Dear Mr. Yelverton:
SUBJECT:
SAFETY EVALUATION OF RESPONSE TO GENERIC LETTER 87-02 ARKANSAS NUCLEAR ONE, UNIT NO. 1 (TAC NO. M69426)
The NRC staff has concluded its review of the licensee's response to Generic Letter (GL) 87-02, Supplement No. 1.
Based on our review of the licensee's response and the staff positions delineated in Supplement No. I to GL 87-02, the staff concludes that the licensee's response is adequate and acceptable and that the floor response spectra (FRS) included in the plant Safety Analysis Report, as supplemented by additional FRS curves given in Attachment I to the licensee's letter of September 18, 1992, may be used for the resolution of Unresolved Safety Issue A-46.
In view of the procedures used in developing the FRS as explained in the enclosed safety evaluation, the staff considers the FRS to be " median-centered," rather than " conservative design" FRS, as defined in Supplement No. I to GL 87-02.
The staff's Safety Evaluation is enclosed.
Sincerely, h*
Roby B. Bevan, Project Manager Project Directorate IV-1 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc w/ enclosure:
See next page
+
i q
-6
. t' f
Mr. Jerry W. Yelverton Entergy Operations, Inc.
Arkansas Nuclear One, Unit I cc:
Mr. Harry W. Keiser Executive Vice Mr. John R. McGaha President & Chin Operating Officer Vice President, Operations Support Entergy Operations, Inc.
Entergy Operations, Inc.
I P. O. Box 31995 P. O. Box 31995 Jackson, Mississippi 39286 Jackson, Mississippi 3978G j
Mr. Charles B. Brinkman, Manager Mr. Robert B. McGehee i
Washington Nuclear Operations Wise, Carter, Child & Caraway i
ABB Combustion Engineering P. O. Box 651 Nuclear Power Jackson, Mississ'.ppi 39286 12300 Twinbrook Parkway, Suite 330 i
Rockville, Maryland 20852 Mr. James J. Fisicaro Director, Licensing l
Mr. Nicholas S. Reynolds Entergy Operations, Inc.
Winston & Strawn Route 3, Box 137G 1400 L Street, N.W.
Russellville, Arkansas 72801 i
Washington, D.C.
20005-3502 l
Admiral Kinnaird R. McKee, USN (Ret) l Mr. Robert B. Borsum 214 South Morris Street Licensing Representative Oxford, Maryland 21654 B&W Nuclear Technologies I
1700 Rockville Pike, Suite 525 Mr. Michael B. Sellman j
Rockville, Maryland 20852 General Manager, Plant Operations Entergy Operations, Inc.
i Senior Resident Inspector Route 3, Box 137G j
. U.S. Nucidar Regulatory Commission Russellville, Arkansas 72801 1 Nuclear Plant Road i
Russellville, Arkansas 72801 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 i
Arlington, Texas 76011 l
Honorable C. Doug Luningham i
County Judge of Pope County
)
Pope County Courthouse Russellville, Arkansas 72801 i
L Ms. Greta Dicus, Director i
Division of Radiation Control l
ud Energency Management Arkeas Department of Health 4815 West Markham Street Little Rock, Arkansas 72205-3867 j
)
I i