Text
-
^P Dn.cket Nos 50-313 and 50-368 Mr. Jerry W. Yelverton Vice President, Operations AND Entergy Operations, Inc.
Route 3 Box 137G Russellville, Arkansas 72801
Dear Mr. Yelverton:
SUBJECT:
EVALUATION OF ENTERGY OPERATIONS, INC'S RESPONSE TO GENERIC' LETTER 87-02, SUPPLEMENT 1, FOR ARKANSAS NUCLEAR ONE, UNITS 1 AND 2 (ANO-1&2) (TAC NOS. M69426 AND M69427)
By letter dated May 22, 1992, the NRC staff issued Supplement I to Generic Letter 87-02 (GL 87-02, Suppl.1).
The letter also transmitted Supplementary Safety Evaluation Report No. 2 (SSER-2) on Seismic Qualification Utility Group (SQUG) Generic Implementation Procedure, Revision 2 (GPI-2), dated February 14, 1992, for resolution of Unresolved Safety Issue (USI) A-46.
By [[letter::0CAN099201, Responds to GL 87-02,Suppl 1 Re Sser 2 on SQUG Generic Implementation Procedure,Rev 2 & GL 88-20,Suppl 4 Re IPEEE for Severe Accident Vulnerabilities,Consisting of Description of Licensing Basis to Resolve USI A-46|letter dated September 18, 1992]], Entergy Operations, Inc. (E0I, the licensee for ANO-l&2), responded to GL 87-02, Suppl.1, and to the NRC staff's SSER No. 2.
By letter dated November 16, 1992, NRC responded to the E01 response of September 18, 1992, interpreting E01 as committing to use the entire GIP-2 in adopting the position of SQUG.
By letter dated January 28, 1993, E01 confirmed the NRC staff interpretation as described in its November 16, 1992, letter, and provided additional-information the NRC had requested to complete its review of this' issue for ANO-l&2.
This is to inform you that your response of January 28, 1993, is under review.
We will inform you of its acceptability when that review is completed.
Sincerely, ORIGINAL SIGNED BY:
Roby B. Bevan, Project Manager Thomas W. Alexion, Project Manager Project Directorate IV-1 Project Directorate IV-1 Division of Reactor Projects III/IV/V Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation Office of Nuclear Reactor Regulation cc:
See next page DISTRIBUTION:. Docket File NRC & Local PDRs PD4-1 Reading R. Bevan M. Virgilio G. Hubbard P. Noonan J. Roe T. Alexion 0GC ACRS (10) (P-315)
A. B. Beach, RIV 0FC LA:PD4-l__.
PM:PQ4 1 PM: PD4,.1 D:PD4-1 _. g 3
4A1NkIo$
JLarkinsk NAME PNoona' Y ' RBehanIpk
(
n d / /93 Y///93 5 4/1/93 d/l/93 g
/
DATE COPY YES M YES/NO YES/N0 YES/NO-1 0 0FFICIAL RECORD COPY Document Name: AR69426.ltr yy g),,, y l y~",?.
'"t.
, 7.,,
9304080096 930401
[y5 M,
i
"~"
~
" ' ' ^ "
~
PDR ADOCK 05000313 j
P PDR
AprH 1,1993 e.-
Docket Nos. 50-313 and 50-368 Mr. Jerry W. Yelverton Vice President, Operations ANO Entergy Operations, Inc.
Route 3 Box 137G Russellville, Arkansas 72801
Dear Mr. Ye1/erton:
SUBJECT:
EVALUATION OF ENTERGY OPERATIONS, INC'S REff0NSE TO GENERIC LETTER 87-02, SUPPLEMENT 1. FOR ARKANSAS NUCLEAR ONE, UNITS 1 AND 2 (ANO-l&2) (TAC NOS. M69426 AND M69427)
By letter dated May 22, 1992, the NRC staff issued Supplement I to Generic Letter 87-02 (GL 87-02, Suppl. 1). The letter also transmitted Supplementary Safety Evaluation Report No. 2 (SSER-2) on Seismic Qualification Utility Group (SQUG) Generic Implementation Procedure, Revision 2 (GPI-2), dated February 14, 1992, for resolution of Unresolved Safety Issue (USI) A-46.
By [[letter::0CAN099201, Responds to GL 87-02,Suppl 1 Re Sser 2 on SQUG Generic Implementation Procedure,Rev 2 & GL 88-20,Suppl 4 Re IPEEE for Severe Accident Vulnerabilities,Consisting of Description of Licensing Basis to Resolve USI A-46|letter dated September 18, 1992]], Entergy Operations, Inc. (E01, the licensee for AND-l&2), responded to GL 87-02, Suppl. 1, and to the NRC staff's SSER No. 2.
By letter dated November 16, 1992, NRC responded to the E01 response of September 18, 1992, interpreting E01 as cortiritting to use the entire GIP-2 in adopting the position of SQUG.
By letter dated January 28, 1993, E01 confirmed the NRC staff interpretation as described in its November 16, 1992, letter, and provided additional information the NRC had requested to complete its review of this issue for ANO-l&2.
This is to inform you that your response of January 28, 1993, is under review.
We will inform you of its acceptability when that review is completed.
Sincerely, ORIGINAL SIGNED BY:
Roby B. Bevan, Project Manager Thomas W. Alexion, Project Manager Project Directorate'IV-1 Project Directorate IV-1 Division of Reactor Projects III/IV/V Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation Office of Nuclear Reactor Regulation cc:
See next page DISTRIBUTION: Docket File NRC & Local PDRs PD4-1 Reading R. Bevan M. Virgilio G. Hubbard P. Noonan J. Roe T. Alexion OGC ACRS (10) (P-315)
A. B. Beach, RIV e
OFC LA:PD4-1 PM:PD4s1 PM:PD4,-J D:PD4-1 g'
NAME PNoonanM)
RBehaNpk
/Al[kio$
JLarkinsk d / /93 Y / / /93
/
d/l/93 k/ l /93 DATE COPY YES/N0't YES/NO YES/NO YES/NO OFFICIAL RECORD COPY Document Name: AR69426.ltr
p
. UNITED STATES g
NUCLEAR REGULATORY COMMISSION n
[
WASHINGTON, D. C. 20555 c
April 1, 1993 Docket Nos. 50-313 and 50-368 l
l l
l Mr. Jerry W. Yelverton Vice President, Operations AND Entergy Operations, Inc.
Route 3 Box 137G l
Russellville, Arkansas 72801
Dear Mr. Yelverton:
SUBJECT:
EVALUATION OF ENTERGY OPERATIONS, INC'S RESPONSE TO GENERIC LETTER 87-02, SUPPLEMENT 1, FOR ARKANSAS NUCLEAR ONE, UNITS 1 AND 2 (ANO-1&2) (TAC NOS. M69426 AND M69427)
By letter dated May 22, 1992, the NRC staff issued Supplement I to Generic Letter 87-02 (GL 87-02, Suppl.1). The letter also transmitted Supplementary Safety Evaluation Report No. 2 (SSER-2) on Seismic Qualification Utility Group (SQUG) Generic Implementation Procedure, Revision 2 (GPI-2), dated February 14, 1992, for resolution of Unresolved Safety Issue (USI)- A-46.
By [[letter::0CAN099201, Responds to GL 87-02,Suppl 1 Re Sser 2 on SQUG Generic Implementation Procedure,Rev 2 & GL 88-20,Suppl 4 Re IPEEE for Severe Accident Vulnerabilities,Consisting of Description of Licensing Basis to Resolve USI A-46|letter dated September 18, 1992]], Entergy Operations, Inc. (E01, the licensee for ANO-1&2), responded to GL 87-02, Suppl. 1, and to the NRC staff's l
SSER No. 2.
i By letter dated November 16, 1992, NRC responded to the E01 response of September 18, 1992, interpreting E01 as committing to use the entire GIP-2 in adopting the position of SQUG.
By letter dated January 28, 1993, E0I confirmed the NRC staff interpretation as described in its November 16, 1992, letter, and provided additional information the NRC had requested to complete its review of this issue for AN0-1&2.
l This is to inform you that your response of January 28, 1993, is under review.-
We will inform you of its acceptability when that review is completed.
Sincerely, if1%-
)
W.
Roby Bevan, Project Manager Thomas
. Alexion, Project Manager Project Directorate IV-1 Project Directorate IV-1 Division of Reactor Projects III/IV/V Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation Office of Nuclear Reactor Regulation cc: See next page
F Mr. Jerry W. Yelverton L
Entergy Operations, Inc.
Arkansas Nuclear One, Units 1 & 2~
cc:
Mr. Donald C. Hintz, President Mr. John R. McGaha and Chief Executive Officer Vice President, Operations Support Entergy Operations, Inc.
Entergy Operations, Inc.
P. O. Box 31995 P. O. Box 31995 Jackson, Mississippi 39286 Jackson, Mississippi 39286 Mr. Robert B. McGehee-Mr. James J. Fisicaro Wise, Carter, Child & Caraway Director, Licensing P. O. Box 651 Entergy Operations, Inc.
Jackson, Mississippi 39205 Route 3 Box 137G Russellville, Arkansas 72801 Mr. Charles B. Brinkman, Manager Washington Nuclear Operations Mr. Nicholas S. Reynolds ABB Combustion Engineering Nuclear Power Winston & Strawn 12300 Twinbrook Parkway, Suite 330 1400 L Street, N.W.
Rockville, Maryland 20852 Washington, D.C.
20005-3502 Admiral Kinnaird R. McKee, USN (Ret)
Mr. Robert B. Borsum 214 South Morris Street Licensing Representative Oxford, Maryland 21654 B&W huclear Technologies 1700 Rockville Pike, Suite 525 Mr. Michael B. Sellman Rockvil'ie, Maryland 20852 General Manager, Plant Operations Entergy Operations, Inc.
t Senior Resident Inspector Route 3, Box IT
- U.S. Nuclear Regulatory Commission Russellville, /.xansas 72801 I Nuclear Plant Road Russellville, Arkansas 72801
-Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Honorable Joe W. Phillips County Judge of Pope County i
-Pope County Courthouse l
Russellville, Arkansas 72801 Ms.-Greta Dieus, Director
)
Division of Radiation Control and Emergency Management Arkansas Department of Health
-j 4815 West Markham Street Little Rock, Arkansas 72205-3867 I
i