Forwards Pump & Valve Inservice Testing Plan for Zion Nuclear Generating Station Units 1 & 2
ML20056G810
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 08/31/1993
From: Simpkin T
COMMONWEALTH EDISON CO.
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
Shared Package
ML20056G811 List:
References
NUDOCS 9309070192
Download: ML20056G810 (12)


Text

[

-- /

N - Commonwrith Edixn

'[ 1 /' 1400 Opus Pires

\\ v Downers Grove, lilinois 60515 e

t

).

August 31,1993 Dr. Thomas E. Murley, Director l

y.

Office of Nuclear Reactor Regulation i

U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attn: Document Control Desk

Subject:

Zion Station Units 1 and 2 Inservice Testing Program for Pumps and Valves, Third Interval NRC Docket Nos. 50-295 and 50-304

Reference:

(a)

June 14,1993 letter from J. Dyer to D.L. Farrar

Dear Dr. Murley:

Enclosed for your review is the Third Interval Inservice Testing (IST)

Program for Pumps and Valves. The Program is in compliance with 10CFR50.55a(f) and the ASME B & PV Code Section XI,1989 edition including OM 1987, Part 1 and addenda OMa 1988, Parts 6 and 10. The Third Interval was scheduled to commence on 12/31/93 for Unit 1 and 9/14/94 for Unit 2.

However, per ASME Section XI,1980 edition with Winter 1981 Addenda, Article-IQA-2400(c), the inspection interval for inservice testing may be extended by as much as one year, enabling Zion to remain in the second Ten-Year Interval during?

the Dual Unit Outage. Commencement of the Third Ten Year Interval is scheduled for 3 months after the end of the Dual Outage, or approximately June, 1994.

The referenced letter transmitted a Safety Evaluation Report for Revision 11/92 of the second interval IST program. In that evaluation, Commonwealth Edison Company's proposal to establish a flow tolerance for certain pumps was determined to require specific relief. These relief requests are include < in the third interval program. For those pumps whose flow tolerance would be less than 2%, no reliefis required, but the method for establishing the variance should be documented in the IST program. Zion Station is currently assembling the required documentation, and it will be maintained on-site, available for staff review.

nwnn.e 9309070192 930831-I D[f gDR ADOCK 05000295 I k:nla: zion:nrcil' it g

L

B I

Dr. T.E. Murley August 31,1993 O

Attachment A contains a summary of the programs, which reconciles the i

third interval program to the current revision of the second interval program.

The program itselfis contained in Attachment B, and Attachment C contains marked-up P & ID's.

Please direct any questions regarding this matter to this ofIice.

t Respectfully, j

%).

T.W. Simpkin Nuclear Licensing Administrator Enclosure cc:

J.B. Martin, Regional Administrator - RIII l

C.Y. Shiraki, Project Manager - NRR J.D. Smith, Senior Resident Inspector - Zion i

i i

)

i s

i L'

k:nla:2ionsnrc:2 w

ATTACHMENT A 1

1 i

o 9

]

1 F

i I

l

}

l

!-l

)

k:nla: zion:nrc:3 i

h s

IST Program Plan Changes From the 2ND Ten Year Interval to the 3RD Ten Year Interval REttEF i IVALVE / PUMP EPN 6 la iIDESCRIPTION i13RD 10 YR 1 APPROVED PR-01 X

W 12'17/87 X

X PR-02 SWOO1-3 T

SW pumps tested in CSD or Refuel.

PR-01 3E 3/93 Added more pump information concerning autostarting pumps.

PR-03 OCCOO3 - 7 D

DELETED X

SE 6/14/93 CSOO1 - 3 Relief was to use OM-6 Enks on FWOO4 - 6 vibration measurements. Not RHOO1-2 necessary any longer da to switch S1003 - 4 to 1989 ASME Section XI Code.

SWOO1 - 3 VCOO6-7 NEW OCCOO3 - 7 T

Vibration Testing PR-02 NEW CSOO1 - 3 Use of RMS (root mean squarel vs.

FWOO4 - 6 peak velocity measurements.

RH001 - 2 JSIOO3-4 SWOO1 - 3 VCOO6-7 PR-04 OCCOO3 - 7 D

. DELETED X

SE 6/14/93 CSOO1 - 3 Bearing temps on pumps are SE 6/91 RHOO1-2 not required per OM-6.

SiOO3 - 4 SWOO1 - 3 VCOO6-7 PR-05 OCCOO3 - 7 D

DELETED X

SE 6/14/93 CSOO1 - 3 Range requirements for Electronic SE 6/91 FWOO4 - 6 DigitalInstruments addresssed in RHOO1-2 OM-6 (4.6.1.2 (c)).

S1003-4 SWOO1 - 3 VCOO6-7 PR-06 X

W 10/1/90 X

' X PR-07 X

W 12/17/87 X

X PR-08 X

W 12/17/87 X

X PR-09 RHOO1 - 2 N

Instrument range for RHR pumps.

PR-03 SE 6/14/93 PR-10 FWOO4 - 6 D

DELETED X

SE 6/14/93 AFW pumps bearing temperatures not required per OM-6.

PR-11 CSOO3 N

Diesel driven CS pumps PR-04 SE 6/26/93 vibration limits.

SE 6/14/93 PR-12 SWOO1 - 3 T

SW pumps PMT during power PR-05 X

operation (added onsite maint.).

SE 6/25/93 1

IST Program Plan Changes From the 2ND Ten Year Interval to the 3RD Ten Year interval i

RELIEF i IVALVE / PUMP EPN Ila tIDESCRIPTION 613RD 10 YR lAPPROVED NEW FWOO4 - FWOO6 A

AFW flow tolerance band usage PR 06 NEW IResponse to SE 6/14/93.

NEW S1003 - S1004 A

Si flow tolerance band usage PR-07 NEW Response to SE 6/14/93.

j i

NEW OCC003 - 7 A

CC flow tolerance band usage PR-08 NEW Response to SE 6/14/93.

t NEW VC006 - 7 A

VC flow tolerance band usage PR-09 NEW i

Response to SE 6/14/93.

i NEW SWOO1 - SWOO3 A

SW flow tolerance band usage PR-10 NEW Response to SE 6/14/93.

1 VR-01 CS0016,21,26 D

DELETED X

SE 6/14/93..

N Added check valves to VR-34 disassembly relief (now VR-04).

l VR-02 LCV-DT1003

,D IDELETED X

SE 6/14/93 AOV-DT9159 A-B These are CIV's supplied by IVSW SE 6/91 AOV-DT9160A-B which will be tested per Zion's CIV DWOO30, 38 program. Thus, relief is no longer FCV-PR19-23 (A-B) needed.

l AOV-RC8025,26,28,29 AOV-RVOO5-6 FCV-RV111-114 l

FCV-SA01 A-B SFOO10, OSF0011-12 i

SF8767,8787 AOV-SS9354-57 (A-B) i MOV-VC8100 AOV-VC8152,3 VCB480A-B l

4 FCV-VF01 A-B FCV-VN02 A-8,WD17 A-B j

'VR-03 VC8481 A-B JD DELETED VO-01 SE 6/14/93 VC8546 N

Charginggmp check valves are SE 6/91 now in VO-01 for refueling frequency.

I VR 04 X

W 12/17/87 X

X f

I VR-05 RH8736A-B D

DELETED VO-02 SE 3/93 RH8949 A-B N

RHR check valves are now in VO-02 j

for refueling frequency.

1 VR-06 S18922A B D

DELETED VO-03 SE 3/93 N

Si pump discharge check valves are now in VO-03 for ref ueling frequency.

VR-07 S18900A-D, Sl8905A-B D

DELETED VO-04 SE 3/93 S18949C-D, S19004C-D N

SI system check valves are now in 1

Sl9012 A-D, Sl9032 VO-04 for refueling frecuency.

2

- =.

i I

IST Program Plan Changes From the 2ND Ten Year Interval to the 3RD Ten Year interval RELIEF I IVALVE / PUMP EPN Ila llDESCRIPTION 113RD 10 YR IAPPROVED VR-08 S18926 D

DELETED VO-05 SE 6/14/93

)

N Si pumps suction from RWST are SE 6/91 now in VO-05 for refueling frequency.

VR-09 Sl8948A-D, Sl8956 A-D T

Rewritten to test accum. check VR-01 X

valves by testing 1 set of 2 valves at refueling instead of disassembly.

i VR-10 X

W 6/17/86 X

X i

l VR-11 X

W 9/91, see VC-23 (now VC-17)

X X

VR-12 IWOO62-70,73 83,90,95 D

DELETED VO-06 SE 3/93 IWO181-186,198 N

IVSW check valves are now in l

VO-06 for refueling frequency.

VR-13 FCV-CC685

-D DELETED X

SE 3/93 i

MOV-CC9414, 38 CIVs to be tested per Appendix J l

MOV-CS002,4,6 as allowed per OM-10. (4.2.2.2).

.CS005,9,13,37,38,40,41 Thus, no longer need relief.

ICS0043-44 TAOV-DT9157, DT9158 l

TFCV-IA01 A-B PR0029 1

FCV-PR24 A-B l

SOV-PR25-26 (A-D)

ADV-RC8033 l

RC8047,RC8079 AOV-RV0001-4 l

AOV-S18880 i

L Sl8857, S18933 i

i VR-14 X

V/

12/17/87 X

X VR-15 X

W 6/17/86 X

X VR-16 X

W 10/1/90 X

X l

VR 17 HOV-MS001 -4 D

DELETED X

SE 3/93 l

SOV-PR25-26 (A-D)

POVs with < 2 sec max stroke tsme i

SOV-RC08-11 are now exempted from reference criteria, i.e. max = 2 secs.

MSIVs can determine reference value per OM-10, not previous result.

VR-18 X

W 9/91 X

X VR-19 X

W 9/91 X

X j

VR 20 X

W 9/91 X

X VR-21 X

W 9/91 X

X l

VR-22 X

W 12/17/87 X

X i

VR 23 VC8542A B T

VC pumps minimum flow check valves VR 02 X

use an indirect method to obtain data SE 6/14/93 i

Rearranged and reworced justification.

- SE 6/91 VR-24 X

W 9/91 X

X VR 25 X

TW 12/17/87 X

X 3

.~

- -. -. -. - -... ~.

l l

l l

l IST Program Plan Changes From the 2ND Ten Year interval to the 3RD Ten Year Interval i

RELIEF i IVALVE / PUMP EPN lia llDESCRIPTION ll3RD 10 YR IAPPROVED VR-26 X

W 12/17/87 X

X VR-2 7 _

S!9001 A-D, Sl9002A-D -

T RHR cold leg injection PlVs VR-03 X

i measure full flow indirectly, at CSD.

SE 6/14/93 Supplemental information deleted.

SE 6/91 VR-28 X

W 12/17/87 X

X VR 29 X

W 12/91 X

X VR-30 X

W 12/17/87 X

X VR-31 X

W 9/91 X

X VR-32 X

W 10/1/90 X

X I

VR-33 S!8958 D

DELETED VO-07 SE 6/14/93 N

RHR pumps suction from RWST now in VO-07 for refueling frequeracy.

VR-34 CC9486,CC9500 T

Check valves requinng disassembly.

VR-04 X

l CS0016,21,26 N

No changes to text other than adding SE 6/14/93 IWOO1, RC8046, 79 CS, IW, and SW valves.

S18958, SWOO10,11 D

VC8378 is passive, no longer OSWOO12 requires testing.

VC8246,8352A-B VC8379 A-3, 8440

[

l-i VR-35 MS0006, MS0007 N_ Turbine driven AFW pump steam VR-05 SE 6/14/93 supply check valves which is already tested full flow, closure by acoustics?

VR-36 IWOOO1 D

IVSW PW makeup check valve VR-04 SE 6/14/93 N

added to VR-34, now VR-04 for disassembly for closure.

VR-37 OSWOO12, SWOO10,11 D

DELETED VR-04 SE 3/93 N

D/G coolers SW supply check valves added to VR-34 (VR-04) for disassembly for closure test.

VR-38 VC8367,68,75 (A-D)

D DELETED VO-08 SE 6/14/93 N

RCP seal water check valves now VO-08, for refueling frequency.

VR-39 VC8224 D

DELFTED VO-09 SE 6/14/93 N

RC loop fill header isolation valves in VO-09 now for refueling frequency.

VR-40 All POVs except D

DELETED X

SE 3/93 2 sec and MSIV vivs OM 10 based on reference values, not previous results.

VR41 MOV-Sl8811 A-B N

Containment recirculation sump VR-06 SE 3h'3 icolation ('CAN') valves relief to test one valve per refueling outage.

4

IST Program Plan Changes f

From the 2ND Ten Year Interval to the 3RD Ten Year interval REUEF 1 iVALVE / PUMP EPN t la llDESCRIPTION 3RD 10 YR lAPPROVED NEW Sl8900A-D, S19032 A

VC pump cold leg inject. check valves VR-07 NEW f

relief for testing valves in series.

J l

NEW VC8367A-D, VC8375A-D A

RCP seal water check valves VR-08 NEW l

1 relief for testing valves in series.

NEW SOV-SWO153 A

CS diesel engine cooler solenoid VR-09 NEW vivs relief for no ability to stroke time.

1I il ll il i

j CSDJ (VC) I IVALVE / PUMP EPN l ta ilDESCRIPTION t 13RD 10 YR I APPrtOVED l

i VC-01 CS0005,9,13 (CIVs)

D IDELETED - CS discharge check X

X valves, in VO-10 for Appendix J test.

VC-02 HOV-MS0001-4 N

Main Steam isolation Valves VC-01 X

VC-03 MOV-RH8703 T

RHR pump discharge to RC hot VC-02 X

j legs. Added more information and I

addressed fear of failure issue.

VC-04 PCV-455C, 456 T

PORVs, added information on LTOP VC-03 X

and GL90-06.

VC-05 MOV-RH8701, 2 N

RHR Pressure Isolation Valves VC-04 X

VC-06 MOV-Sl8802, 6,13,14 T

Si injection valves, fear of f ailure.

VC-05 X

MOV-VC8110,11 Added MOV-VC8110,11 i

i VC-07 AOV/MOV-MS0017-20

.D DELETED, Atmospheric relief valves X

X can ce tested quarterly.

I VC-08 MOV-FWOO16-19 T

Steam gens ator inlet isolation valves.

VC-06 X

Conditions for testing changed.

VC-09 MOV-Sl8812 A - B T

RHR pump suction isolation valves VC-07 X

fear of failure, added information.

j VC-10 DT9158 D

DELETED - RC drain tank CIVs X

X

- now in VO-10 for Appendix J testing.

i VC-11 MS0008 - 11 N

Main Steam isolation check valves.

VC-08 X

VC-12 PR0029 D

DELETED - Cont. air sampling check X

X j

CIVs now in VO-10 for Appdx J testing.

VC-13 RH0257,258 T

Rewritten for technical justification.

VC-09 X

VC-14 LCV-RC459, 460

D DELETED, These are being X

X MOV-VCLCV-112B -E tested quarterly in PT-20-ST.

MOV-VC8105, 6,10,11 Charging and letdown isolation vivs.

AOV-VCB146, 8152, 53 D

AOV-VC8146 is passive, only PIT.

l i

VC-15 MOV-FWOO74 -76 D

DELETED, can test these AFW pump X

X suction isolation valves cuarterly.

rf 5

i

. ~ - - - -..

IST Program Plan Changes From the 2ND Ten Year Interval to the 3RD Ten Year Interval CSDJ (VC) i IVALVE / PUMP EPN Ila i tDESCRIPTION ll3RD 10 YR 1 APPROVED VC-16 S18957 A - B T

RHR cold leg injection check valves VC-10 X

Rejustified due to Unresolved item.

VC-17 RH8730A - B N

RHR pump discharge check valves.

VC 11 X

VC-18 S19001 A - D, 9002 A - D T

RHR cold leg inject. PI Vs check vivs.

VC-12 X

Rejustified due to Unresolved item.

VC-19 FCV-1A01 A - B T

IA supply iso l. vivs. to containment VC-13 X

fear of failure, added more information.

VC-20 MOV-VC8100 N

RCPs seat return isolation valve.

VC-14 X

j (Approved thru VR-20, SE 6/91J VC-21 SOV-RC08 - 11 T

Reactor head vent valves. Added VC-15 X

more technical info for justification.

r VC-22 Sl8808A - D

~

Nl Si accumulator check vivs.

VC-16 X

VC-23

.FCV-CC685 T

CC to RCPs isolation valves.

VC-17 X

iMOV-CC9413A-B 14,15 Added more technical justification.

j RtwOV-CC9438 i

VC-24 S!8948 A - D, 8956A - D T

Si accum. check valves - rewritten to VC-18 X

restate justification more clearly.

l VC-25 SWOOO1, 4, 7 N

SW pumps discharge check vivs VC-19 X

P&lD number and coord. changes VC-26 RC8047, 8079, Sl8933 D

DELETED, Cont. isolation check vivs.

X

. X OM-10 uses Appendix J for CIV testing, i

VC-27 OCC9464, CC9463A - B D

DELETED, CC pumps discharge X

X check valves tested quarterly.

VC-28 MOV-CS0049, 50 D

DELETED, RHR supply to cont.

X X

spray isolation valve not needed.

1 NEW MOV-RH8716 A, B, C A

Multiple inoperabilities if test at power, VC-20 X

I MOV-RH9000 thus, these valves will be tested at CSD.

MOV-S18809A, B l

l I

I ROJ (VO) 1 ! VALVE / PUMP EPN Ila IiDESCRIPTION il3RD 10 YR 1 APPROVED l

VO-01 VC8481 A - B, VC8546

}R Charging pump check valves for VO-01 X

N refueling frequency, granted in SE 6/91 as VR-03.

VO-02 RH8736A -B, 894 9 A-D R

RHR hot leg injection check valves VO-02 X

l N

for refueling freq. (granted as VR 05 in SE 3/93).

l 1

i i

j 6

~ ~ -

_ ~ ~

IST Program Plan Changes From the 2ND Ten Year interval to the 3RD Ten Year Interval ROJ IVO) l IVALVE / PUMP EPN Ila lIDESCRI? TION ll3RD 10 YR l APPROVED VO-03 Sl8922A - B R

SI pumps discharge check valves for VO-03 X

N refueling frequency (VR-06 in SE 3/93).

VO-04 S18900A-D, 8905 A-D R

Si system check vivs, for refueling VO-04 X

S18949C-D, 9004C-D N

frequency with valves added to their S19012 A-D, S19032 descriptions in text (VR-07 in SE 3/93).

l VO-05 Sl8926 R

SI pumps suction from RWST VO-05 X

N check valve for refueling (VR-08 6/91).

VO-06 IWOO62 70,73-83,90,95 R

IVSW check valves, for refueling freq.

VO-06 X

4 IWO181 -186,198 N

(VR-12 granted in SE 6/91 + 3/93).

VO-07 S!8958 R

_RHR pumps suction from RWST VO-07 X

T check viv for refueling (VP-33 6/93 with conditions), minor rewording.

l VO-08 IWOOO1 R

- DELETED, IVSW PW makeup check X

X I

D valve added to VR-34 (now VR-04)

(before = VR-36 granted in SE 6/14/93).

VO-09 VCS367,68,75 (A-D)

R RCP seal water check valves for VO-08 X

N refueling freq. (VR-38 in SE 6/14/93j.

NEW VC8224 A

VC check valve on RC loop fill hne VO-09 X

for refueling (VR-39 granted 6/14/93).

NEW CS0005,9,13, DT9158 A

Appendix J CIVs check valves for VO-10

.X PR0029,RC8047,8079 ref ueling f requency.

S18933 ll Il il il I

POSITION I IVALVE/ PUMP SUBJECT Ila 11 DESCRIPTION ll3RD 10 YR IAPPROVED l

'i i

VP-01 FST testing method N

Method for testing failsafe valves VP-01 X

j VP-02 1 sol. vivs during power N

isol. valves during power operation VP-02 X

VP-03 T. Spec 4.4 stroking freq.

T Tech Spec 4.4 stroking frequency VP-03 X

i Added reference to UFS/ 't 16.3-3.

I VP-04 CC check valves N

Out of service potential.

VP-04 X

VP-05 Cold Shutdown defntn.

jT Added ROJ to CSD definition position.

VP-05 X

l VP-06 FST of sys. control vivs T

Added closed position.

VP-06 X

VP-07 MOV Sl8801 A-B,8803A-B D

BIT removal not affect vivs any more.

X X

VP-08 Augmented vivs testing N

Augmented valves scope and testing.

VP-07 X

l Minor rewording change.

PP-01 (Range hmits for pumps D

DELETED, not needed any longer.

X X

PP-02 lX W

- DELETED, not needed any longer.

X X

PP-03 Initial suct. press (pumps)

D DELETED, not needed any longer.

X

X PP-04 X

W 9/91 X

X PP-05

,DFOTP testing N

Augmented program, no relief s, etc.

PP-01 X

PP-06

{X W

9/91 X

X PP-07 l Inlet press (SW pumps)

D

. Level of lake water used in determ.

X X

{

not necessary any longer (per OSR).

I PP-08 iPump reference values ID Resnonse to SE 6/14/93 in form of X

X I

l l relief s PR-06 thru PR 10.

I II il I!

Il I

i 7

4

..n_

_. ~. -.. -.. _ _ _... - -

. ~ -.

l l

From the 2ND Ten Year interval to the 3RD Ten Year interval IST ProDram Plan Changes 1

\\

l t

l t

i i ABBREVIATIONS i

PR PUMP RELIEF REQUEST

=

VALVE RELIEF REQUEST j

VR

=

COLD SHUTDOVvN JUSTIFICATION I

VC

=

REFUELING OUTAGE JUSTIFICAT.

l VO

=

1 VP VALVE POSITION

=

PUMP POSITION l

PP

=

SYMBOL DENOTES THE CHANGE A

=

ABSOLUTELY NEW A

=

D DELETED

=

NONE / MINOR

'N

=

NEW (previously a VR, now a VO) l R

=

TECHNICAL l

T

=

W WITHDRAWN

=

NOT APPLICABLE X

=

I I

i I

h 9

  • N could include:
1. Update to new Code (ar9 references) l
2. P&lD changes
3. Minor wording changes for clarity I

i Il li Il DEFINITIONS:

1i li ii AFW auxiliary feedwater

=

T CC component cooling

=

CIV containment isolation valve

=

C_S containment spray

=

i D/G diesel generator

=

DFOTP diesel generator fuel oil transfer pump

=

IA instrument air

=

IVSW isolation valve seal water

=

piping and instrumentation diagram l

P&lD

=

pressure isolation valve PlV

=

PMT post maintenance testing

=

PW pnmary water

=

RC freactor coolant

=

i RCP reactor coolant pump

=

RHR residual heat removal

=

SI safety injection

=

SW service water j

=

VC centrifugal charging

=

vivs valves

=

i i

8 ti t

I

..m

._r.,.

i i

i w

1 1

1 1

)

1 1

1 1

l l

l A'ITACHMENT B l

J i

h

?

i i

'?

i I

i

+

i i

1 i

i i

t, k

1 4

i 4

1 i

s 6

i kinlarzionsnrc:4

, -.