PHILADELPHIA ELECTRIC COMPANY LIMERICK GENERATING STATION P. O. BOX 2300 SANATOGA. PA 194 4 -2300 10C R50 6$
(215) 327-1200, EXT, 3000 R
G Dggpnr August 18, 1993 LIMERICK GENERATING STATION Docket Nos. 50-352 50-353 License Nos. NPF-39 NPF-85 U.
S.
Nuclear Regulatory Commission Attn:
Document Control Desk Washington, DC 20555
Subject:
Limerick Generating Station, Units 1 and 2 1)
Semi-Annual Effluent Release Report No. 18, January 1, 1993 through June 30, 1993.
Gentlemen:
Enclosed is the Semi-Annual Effluent Release Report No. 18, for Limerick Generating Station (LGS), Units 1 and 2, for the period January 1.
1993 to June 30, 1993.
This report is being submitted in accordance with the LGS Technical Specification Section 6.9.1.8 and 10CFR50.36(a).
Very truly yours, 1
(
\\
=-
FJH/sah Enclosures cc:
T. T.
Martin, Administrator, Region I, USNRC (w/ enclosure)
Neil Perry, USNRC Senior Resident Inspector, LGS (w/ enclosure)
[-
01000.
9309020058 930630 h
l k I
PDR ADOCK 05000352 l R
PDR b L
j
__ J
l I
SEMI-ANNUAL EFFLUENT RELEASE REPORT NO. 18 JANUARY 1, 1993 THROUGH JUNE 30, 1993 c
PHILADELPHIA ELECTRIC COMPANY LIMERICK GENERATING STATION UNITS NO. 1 AND 2 DOCKET NO. 50-352 (Unit 1)
DOCKET NO. 50-353 (Unit 2)
Submitted to The United States Nuclear Regulatory Commission I
Pursuant to Facility Operating License NPF-39 (Unit 1) and NPF-85 (Unit 2)
' T, N 4
R.W.
- Boyce, Plant 6 Manager
-3+
9 i
i TABLE OF CONTENTS r
6 I.
Introduction II.
Tables A.
Summary of Radioactive Gaseous Effluents B.
Summary of Radioactive Liquid Effluents i
C.
Solid Waste Disposition Report t
III. Attachments Assumptions Used in Report A.
Supplemental Information Generation
{
i P
6 i
P a
?
l i
I.
INTRODUCTION This submittal complies with the format describe in Regulatory Guide 1.21,
" Measuring, Evaluating and Reporting Radioactivity in Solid Wastes and Releases of Radioactive i
Materials in Liquid and Gaseous Effluents from Light-Water Cooled Nuclear Power Plants", Revision 1, June, 1974.
l The following information is included as Tables to this a
report-l A summary of the gaseous and liquid effluent releases for the report period.
Where "O.00E+00" is used, it denotes the less than detectable level for the given isotope.
l Composite particulate air samples, counted for beta emitters (eg. Sr-89, Sr-90), are submitted to an offsite vendor laboratory for analysis.
Since data for the second quarter particulate air samples were not available at the time this report was prepared, it will be necessary to submit an addendum in the future if second quarter particulate air samples results are reported
>LLD.
Since Limerick Technical Specification limits for liquid and gaseous effluent releases are stated in terms of l
l quarterly and annual offsite doses, " percent technical specification limit" is given as 0.00E+00.
i A summary of solid waste dispositioned during the report l
period, to include: total activity shipped by waste type l
and an estimate of the error in the reported totals; the l
estimated composition of each type of waste by isotope; j
the number of shipments, mode of transportation, i
destination, type of container, total container volume, i
and solidification agent.
t There were no changes to the Offsite Dose Calculation j
Manual (ODCM) or Radioactive Waste Treatment Systems during the report period.
l r
i 4
f
2 I
II.
TABLES A.
SUMMARY
OF RADIOACTIVE GASEOUS EFFLUENTS January 1, 1993 to June 30, 1993 M~
~.~
i e
t 7
EITE: LIMERICK l
.- UNIT: U1 l
USER. MART-DATE:.08/26/93 07:55
+
EFFLUENT AND WASTE DISPOSAL REPORT l
GASEOUS EFFLUENTS -- SUMMATION OF ALL RELEASES i
,4
- UNITS :
QUARTER JUARTER EST. TOTAL:
1 2
- ERROR,
'f A. FISSION AND ACTIVATION GASES r
1
- 1. TOTAL RELE'ASE CI-
- 0.422Ef02 : 0.155Ef03 : 0.453E4 02 : '
j s
- 2. AVERAGE RELEASE
- UCI/SEC: 0.543E401 : 0.197Ef02 :
RATE FOR FERIOD t
- 3. PERCENT OF TECHNICAL:
- 0.000E400 1 0 000Ef00 SFECIFICATION LIMIT :
?
h F. 10 DINES l
- 1. TOTAL 10 DINE-I31 CI
- 0.117E-02 : 0.25BE-02
- 0.453E402 :
4 s
t
- 2. AVERAGE RELEASE
- UCI/SEC: 0.250E-03 : 0.32BE-03 :
RATE FOR PERIOD
- 3. PERCENT OF TECHNICAL:
- 0.000E400 : 0.000Ef00 i' SPECIFICATION LIMIT
- C. PARTICULATES l 1. PARTICULATES WITH
- CI
- 0.968E-04 0.000Ef00 : 0.453Ef02 ;
t HALF-LIVES >0 DAYS o
- 2. AVERAGE RELEASE UCI/SEC: 0.I25E-04 : 0.000Ef00 ;
RATE FOR PERIOD
! 3. PERCENT OF TECHNICAL:
0.000E400 : 0.000Ef00 :
SPECIFICATION LIMIT :
)
- : 4. GROSS ALPHA CI
- 0.000Ef00 : 0.000Ef00':
RADI0 ACTIVITY l
i't D. TRITIUM l 1. TOTAL RELEASE CI
- 0.000E400 : 0.000E400 : 0.453Ef02 :
L
- 2. AVERAGE RELEASE
- UCI/SEC: 0.000Ef00 0.000Ef00 :
l t'
RATE FOR PERIOD i
i
- 3. PERCENT OF TECHNICAL:
t'O.000Et00 : 0.000Ef00 :
)
SPECIFICATION LIMIT :
_I J
-j t
.e PAGE 2 0F 12 j
SITE: LIMERICK
- UNIT: U1 a
i USER: MART DATE:'08/26/93 07:56 f
EFFLUENT AND UASTE DISPOSAL REPORT i
)
GASEOUS EFFLUENTS FOR RELEASE POINT:
1 NORTH STACK y
CONTINUDUS MODE BATCH MODE'
- -NUCLIDES
- UNITS :
GUARTER QUARTER GUARTER :
DUARTER :
-?
! -RELEASED :
1 2
1 2
,t
- 2. 20 DINES 1131 CI
- 0.117E-02 : 0.258E-02 : 0.000Ef00 0.000Ef00 :
I' 1133 CI
- 0.000Ef00 : 0.240E-04 : 0.000Ef00 : 0.000E400 :
- ' TOTAL FOR :
i
- PERIOD CI
- 0.117E-02 : 0.260E-02 : 0.000Ef00 : 0.000Et00,:
?!
(ABOVE) i
- f r
v 3.-PARTICULATES j
C14
- CI
- 0.000Et00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :.
f CR51 CI
- 0.000Ef00 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
i t
- MN54 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :-0.000Ef00 l-t
+
l l EE59 CI
- 0.000Ef00 : 0.000Ef00 : 0.000E400 : 0.000Ef00 :
C058 CI
- 0.000E400 : 0.000Ef00 : 0.000E400 : 0.000Ef00 *.
[
C060 CI
- 0.000Ef00 0.000Ef00 : 0.000Ef00 0.000EiOO :
l
- ZN65 CI
- 0.000Ef00 : 0.000E400 : 0.000E400 : 0.000Ef00 :
[
t
- SRS9 CI
- 0.000Ef00 : 0.000E400 : 0.000Ef00 : 0.000Ef00 :
1
- SR90 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
l
+
'ZR95 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
1
- SB124 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
1 CS134 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :-
1 3
CS136 CI
- 0.000Ef00 0 000Ef00 : 0.000Ef00.1 0.000EiOO :
i CSI37 CI
- 0.000Ef00 0.000Ef00 0.000E400 : 0.000E400 :
']
ENTERLE C ] TO ERASE SCREEN AND CONTINUE':
C
.i 1
J 4
~ --
4 '
g PAGE 40F12
.t SITE:-LIMERICK i
UNIT: U1 USER: MART
-DATE: 08/26/93 07:57 i
EFFLUENT AND WASTE DISPOSAL REPORT l
GASEDUS EFFLUENTS FOR RELEASE POINT:
2 UNIT 1 - SOUTH STACK r
CONTINUOUS MODE BATCH MODE j
- NUCLIDES
- UNITS :
QUARTER QUARTER QUARTER :
GUARTER :
- RELEASED 1
2 1
2 i
- 1. FISSION GASES l
l AR41
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000E400 : 0.000EiOO :
i j
KR23M
- CI
- 0.000Ef00 : 0.000Ef00 0.000E400 : 0.000Ef00 :
't
- KRS5M CI
- 0.000Ef00 : 0 000E400 : 0.000Ef00 : 0.000Ef00 :
l
-_----_-__------__-_--_--_-__------------------_-----..------e--_---
- - KRB5
- CI
- 0.000Ef00 : 0.000E400 : 0.000EiOO : 0.000E400 :
- KRB7
- CI
- 0.000E+00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
~;. KRBS CI
- 0.000E400 : 0.000Ef00
- 0.000Ef00 : 0.000EiOO :
-KRS9
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
4 KR90
- CI
- 0.000Ef00 0.000Ef00 : 0.000Ef00 : 0.000El00 :
- XE131M
- CI
- 0.000Ef00 1 0.000E400 : 0.000Ef00 : 0.000EiOO :
l
! XE133M CI
- 0.000Ef00 : 0.000EiOO : 0.000Ef00 : 0.000Ef00 :
XE133 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000Ef00
- i XEI35M CI
- 0.000Ef00 0.000Ef00 : 0.000EiOO : 0.000E400 :
.i XE135 CI
- 0.396Ef02 : 0.147Ef03 : 0.000Ef00 : 0.000Ef00 :
l XE137
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000EiOO :
XE138
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000E400 : 0.000E400 :
i -
TOTAL FOR :
i
- PERIOD
- CI
- 0.386Ef02 : 0.147Ef03 : 0.000Ef00 0.000Ef00 :
(AF0VE)
' ENTER E C 3 TO ERASE SCREEN AND CONTINUE :
C
PAGE 6 Or 12 l
SITE: LIMERICE UNIT: UI USER. HART DATE: 08/26/93 07:58
-i 6
EFFLUENT AND WASTE DISPOSAL REPORT I
GASEOUS EFFLUENTS-FOR RELEASE POINT: 2 UNIT 1 - SOUTH STACh j
l t
I CONTINUOUS MODE FATCH MODE NUCLIDES : UNITS :
GUARTER GUARTER : GUARTER DUARTER :
I t
- RELEASED :
1 2
1 2
j
}
-------------------------~~-------------------..-
- 3. PARTICULATES (CONTD) l PA140 CI
- 0.000E400 : 0.000Ef00 ; 0.000E400 : 0.000E400 :
CE141 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Et00 :
i CE144 CI
- 0 297E-04 : 0.000Ef00 : 0.000E400 : 0.000E400 :
- TOTAL FOR
PERIOD CI
- 0.968E-04 : 0.000E+00
- 0.000Ef00 : 0.000Ef00 :
(ABOVE) i 1
ENTER E C 3 TO ERASE SCREEN AND CONTINUE :
C i
L h
T i
t f
f I
r 1
.j l
i 1
=
./
PAGE C OF 12 SITE: LINERICL UNIT: U1 USER
- MART DATE: 00/26/93 07:59 EFFLUENT AND WASTE DISPOSAL REPORT GASE0L'S EFFLUENTS FOR RELE ASE POINT:
3 UNIT 2 - SOUTH STACR CONTINUGUS h0DE 14ATCH N0DE NUCLIDES : UNITS :
OUARTER DUARTER :
00ARTER :
QUARTER RELEASED :
1 2
1 2
- 2. 10 DINES 1131 C1
- 0.000EiOO : 0.000EiOO : 0.000Ef00 : 0.000E400 ;
1133
- CI
- 0.000E400 : 0.000E400 : 0.000E400 : 0.000E400 :
10TAL FOR :
PERIOD 01
- 0.000Ef00 : 0.000E400 : 0.000E400 : 0.000Ef00 :
( A F O'.'E )
3.
ETICULATEE C14
- CI
- 0.000E400 : 0.000Ef00 : 0.000Ef00 : 0.000E400 :
CR51 CI
- 0.000E400 : 0.000E400 : 0.000Ef00 : 0.000E400 :
HN54 CI
- 0.000E400 : 0.000E400 : 0.000E100 : 0.000E400 :
FE59 CI
- 0.000E400 : 0.000E400 : 0.000E400 : 0.000Ef00 :
- COLD C:
- 0.000E400 : 0.000E400 : 0.000E100 : 0.000E400 :
- C060 C1
- 0.000Ef00 : 0.000E400 : 0 000E400 : 0.000E400 :
2N65 CI
- 0.000E400 : 0.000E400 0.000Ef00 : 0.000Ef00 :
r SR89 CI
- 0.000E400 : 0.000E400 : 0.000E400 : 0.000Ef00 :
- ER90
- CI
- 0.000E400 : 0.000E400 : 0.000Ef00 : 0.000Ef00 :
ZR95
- CI
- 0.000E400 : 0.000E400 : 0.000EiOO : 0.000E400 :
SP124 CI
- 0.000E400 0.000E400 : 0.000E400 : 0.000E400 :
CS134 CI
- 0.000EiOO : 0.000EiOO : 0.000E400 : 0.000EiOO :
- CSf36 CI
- 0.000Ef00 : 0.000E400 : 0.000EiOO : 0.000E400 :
CS137 CI
- 0.000E400 : 0.000E400 : 0.000E400 : 0.000E400 :
ENTER E C 3 TO ERASE SCREEN AND CONTINUE :
C
/
PAGE 10 0F 12 SITE: LIMERICE UNIT: U1 USER: MART DATE: 08/26/93 07:59 EFFLUENT AND UASTE DISPOSAL REPORT GASEDUS EFFLUENTS FOR RELEASE POINT:
4 HDT MAINTENANCE SHOP CONTINUOUS MODE DATCH MODE NUCLIDES
- UNITS :
GUARTER :
00ARTER :
GUARTER :
QUARTER
- RELEASED 1
2 1
2 l
- 1. FISSION GASES AR41 CI
- 0.000Ef00 : 0.000EiOO : 0.000E400 : 0.000Ef00 :
- ERS3M CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
- LRB5M CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
- LRES
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000E+00 :
- ERS7 CI
- 0.000E400 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
- ERSS C1
- 0.000Ef00 : 0.000EiOO : 0.000Ef00 : 0.000Ef00 :
NRB9 CI
- 0.000Ef00 : 0.000E400 : 0.000Ef00 : 0.000E400 :
- ER90 CI
- 0.000Ef00 : 0.000Ef00 : 0.000E400 : 0.000Ef00 :
- XE131M CI
- 0.000Ef00 : 0.000EiOO : 0.000Ef00 : 0.000EiOO :
- XE132M CI
- 0.000E400 : 0.000Ef00 : 0.000E400 : 0.000Ef00 :
XE133 CI
- 0.000Ef00 : 0.000Ef00
- 0.000Ef00 : 0.000Ef00 :
! XE135M CI
- 0.000Ef00 ; 0.000Ef00 : 0.000Ef00 : 0.000E400 :
- XE135
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
- XE137 CI
- 0.000E400 : 0.000E400 : 0.000E400 0.000L100 :
- XE138 CI
- 0.000Ef00 : 0.000E400
- 0.000Ef00 : 0.000Ef00 :
- TOTAL FOR :
- PERIOD
- CI
- 0.000Ef00 : 0.000Ef00 0.000Ef00 : 0.000Ef00 :
(APOVE)
ENTER C C ] TO ERASE SCREEN AND CONTINUE :
C i
PAGE 12 DF 12 SITE: LIMERICK
. UNIT: U1 USER:-MART DATE: 08/26/93 08:01 EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS FOR RELEASE POINT:
4 HOT MAINTENANCE SHOP CONTINUDUS MODE FATCH MODE
- NUCLIDES : UNITS : DUARTER : CUARTER DUARTER :
00ARTER :
- : RELEASED 1
2 1
2
- 3. PARTICULATES (CONTD)
- FA140 CI
- 0.000Ef00 : 0.000Ef00 : 0.000E400 0.000Ef00 :
- ; CE141 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
CE144 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
l TOTAL FOR :
- FERIOD
- CI
- 0.000Ef00 : 0.000Ef00 0.000Ef00 : 0.000Ef00 :
(ABOVE)
ENTER E C ] TO ERASE SCREEN AND CONTINUE :
C a
i II.
TABLES B.
SUMMARY
OF RADIOACTIVE LIQUID EFFLUENTS January 1, 1993 to June 30, 1993 i.
l I
~
.SJTE: ' LIMERICK UNIT: UI USER: MART DATE: 08/26/93 08:01 EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS -- SUMMATION OF ALL RELEASES j
)
UNITS : QUARTER :
QUARTER :EST.
TOTAL:
1 2
- ERROR,' %
A. FISSION AND ACTIVATION PRODUCTS i 1. TOTAL RELEASE (EXCL.:
CI
- 0.387E-01 : 0.111E-01 : 0.62BEiO: :
TRIT., GASES, ALPHA):
- 2. AVERAGE DILUTED
- UCI/ML : 0.281E-06 0.70SE-07 :
CONC. DURING PERIOD :
1
- 3. PERCENT OF
- 0.000Ef00 0.000Ef00 :
APPLICADLE LIMIT B. TRITIUM l 1. TOTAL RELEASE CI
- 0.779E401 : 0.452Ef01 : 0.62SEf01 :
- 2. AVERAGE DILUTED UCI/ML.: 0.565E-04 0.289E-04 :
CONC. DURING PERIOD *
- 3. PERCENT OF
- 0.000Ef00
- 0.000Ef00 :
APPLICAFLE LIMIT C. DISSDLVED AND ENTRAINED GASES
- 1. TOTAL RELEASE CI
- 0.241E-01 : 0.628E-01 : 0.628Ef01 :
l 2. AVERAGE DILUTED UCI/ML : 0.175E-06 0.402E-06
- CONC. DURING PERIOD l
3.= PERCENT OF
- 0.873E-01 : 0.201Ef00 APPLICABLE LIMIT
'I l
D. GROSS ALPHA RADI0 ACTIVITY
- .1. TOTAL RELEASE
- CI
- 0.000Ef00 : 0.000Ef00 : 0.62BEf01 :.
1 l
.E. VOLUME WASTE RELEASED LITERS : 0.152E407 :-0.171Ef07 : 0.000Ef00 :
L (PRIOR TO DILUTION) l F. VOLUME DILUTION WATER LITERS : 0.138Efo9 : 0 156Ef09 : 0.000EiOO :
- USED DURING PERIOD j
PAGE 1 0F 5 SITE:-LIMERICK UNIT: U1 USER: MART DATE: 08/26/93 08:01 EFFLUENT AND UASTE DISPOSAL REPORT LIQUID EFFLUENTS FOR RELEASE POINT:
1 LIDUID RAD WASTE DISCHARGE TO SCHUYLKILL RIVER CONTINUDUS MODE IATCH MODE NUCLIDES
- UNITS : QUARTER :
QUARTER :
DUARTER : QUARTER :
- RELEASED :
1 2
1 2
- H3
- CI
- 0.000Ef00 : 0.000Ef00
- 0.779Ef01
- 0.452Ef01 l
C14
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00
- NA24 CI.
- 0.000Ef00 : 0.000E+00 : 0.174E-03 0.456E-04 :
P32
- CI
- 0.000Ef00 0.000Ef00 : 0.000E400 : 0.000Ef00 :
- CRS1
- CI
- 0.000Ef00 : 0.000Ef00 : 0.114E-01 : 0.225E-02 :
l HN54
- CI
- 0.000Ef00 : 0.000E400 : 0.308E-02 : 0.344E-03 :
MN56 CI
- 0.000Ef00 : 0.000Ef00 : 0.000EiOO : 0.000Ef00 :
FE55 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
- FE59
- CI
- 0.000Ef00 : 0.000Ef00 0.468E-03 : 0.782E-05 :
i
- C058 CI
- 0.000E400 : 0.000Ef00 : 0.744E-03 :'O.80DE-04 :
C060
- CI
- 0.000Ef00 0.000Ef00 : 0.53BE-02 : 0.146E-02 :
- NI63
- CI
- 0.000Ef00 : 0 000Ef00 : 0-.000Ef00 : 0.000Ef00 :
NI65
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
~~---------------------------..--.-------------------
CU64 CI
- 0.000EiOO : 0.000Ef00 : 0.000Ef00 : 0.000EiOO :
l 2N65
- CI
- 0.000Ef00 : 0.000Ef00 0.501E-02 :'0.116E-02 2N69 CI
- 0.000Ef00 : 0.000E400 : 0.000EiOO : 0.000E400 :
- PRS 3
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 0.000Ef00 t
- FR04 CI
- 0.000Ef00 : 0.000Ef00 0.000Ef00 : 0.000Ef00 :
s.----------_-------
IRBS l'
CI
- 0.000Ef00 : 0.000Ef00 : 0.000E400 0.000Ef00 :
ENTER [ C 3 TO ERASE SCREEN AND CONTINUE :
C e
I is ul PAGE 2 0F 5 SITE' LIMERICK UNIT: U1 udER: MART
'DATE: Ob/2'/93 08:02 EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS FOR RELEASE POINT:
1 LIQUID RAD WASTE DISCHARGE TO SCHUYLAILL RIVER CONTINUDUS NODE FATCH NODE NUELIDES : UNITS :
QUARTER :
DUARTER :
DUARTER :
GUARTER :
- RELEASED :
1 2
1 2
LIQUID EFFLUENTS (CONTD)
- RF96 CI
- 0.000E400 : 0.000Ef00 0.000Ef00 : 0.000Ef00
- RFBB CI
- 0.000Ef00 : 0.000E+00 : 0.000EiOO : 0.000EiOO
- RFB9 CI
- 0.000E400 : 0.000E+00 : 0.000Ef00 : 0.000E100 :
SRB 9 CI
- 0.000E400 0.000Ef00 : 0.461E-02 : 0.000EiOO :
. )
i SR90 CI
- 0.000Ef00 : 0.000Cf00 : 0.281E-03 : 0.000Ef00 :
i j
SR91 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
SR92 CI
- 0.000E+00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
Y90 CI
- 0.000Ef00 : 0.000EiOO : 0.000EiOO : 0.000E400 Y91M CI
- 0.000Ef00 0.000EiOO : 0.305E-04 : 0.227E-04 :
- - Y91
- CI
- 0.000Ef00 : 0.000EiOO : 0.000Ef00 ! 0.000E400 :
Y92 CI
- 0.000E400 : 0.000EiOO : 0.196E-03 : 0.796E-04 :
Y93
- CI
- 0.000EiOO 0.000E400 : 0.000E400 : 0.000EiOO :
-: 2R95-
- CI
- 0.000Ef00 : 0.000E400 0.240E-03 : 0.300E-05 :
- - ZR97
- CI
- 0.000E400 : 0.000EiOO : 0.000Ef00 : 0.000Ef00 :
1:- NF95 CI
=
0.000E400 : 0.000Ef00 : 0.5S7E-03 : 0.000E-05-2 N099
- CI
- 0.000Ef00': 0 000E400 0.147E-03 : 0.325E-04 :
TC99M CI
- 0.000EiOO : 0.000E400 : 0.147E-03 ; 0.325E-04 :
TC101 CI
- 0 000EiOO : 0.000Cf00 :.0.000Ef00 : 0.000E400 :
ENTER E C J TD ERASE SCREEN AND CONTINUE :
C i
PAGE 3 0F 5-SITE: LIMERICK l
UNIT
- U1 i
USER: MART DATE: 08/26/93 08:02 i
EFFLUENT AND WASTE DISPOSAL REPORT LIOUID EFFLUENTS FOR RELEASE POINT:
1 LIQUID RAD WASTE DISCHARGE TO SCHUYLKILL RIVER b
CONTINU005 MODE BATCH MODE i
NUCLIDES : UNITS :
GUARTER 00ARTER DUARTER DUARTER i
f RELEASED :
1 2
1 2
I l
LIDUID EFFLUENTS (CONTD)
RU103
- CI
- 0.000Ef00 : 0.000EiOO : 0.288E-03 : 0.382E-05 i
RU105 CI
- 0.000E+00 : 0.000E400 : 0.000E400 : 0.000Ef00 :
l RU106 CI
- 0.000E400 : 0.000E+00 : 0.000Ef00 : 0.000E400 :
.i i
- AG110M CI
- 0.000Ef00 : 0.000E+00 : 0.000Ef00 : 0.000Ef00 :
l TE125M CI
- 0.000Ef00 : 0.000E400 : 0.000Ef90 : 0.000E400 :
M TE127M CI
- 0.000E+00 : 0.000Ef00 : 0.000EiOO 0.000Ef00 :
I i
TE127 CI
- 0.000Ef00 : 0.000E+00
- 0.000E400 0.000Ef00 :
j y
TE129M
- CI
- 0.000E+00 : 0.000E400 : 0.000Ef00 : 0.000E100 :
l
-1 TE129 CI
- 0.000EiOO : 0.000E+00 0.000E+00 : 0.000Ef00 :
4 4
TE132M CI.
- 0.000E400 1 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
i TE131 CI
- 0.000E+00 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
TEI32 CI
- 0.000Ef00 0.000E+00 1 0.000Ef00 : 0.000Ef00 :
i 1130
- CI
- 0.000E+00 :-0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
1131
- CI
- 0.000Ef00 0.000Ef00 : 0.697E-03 ! 0.724E-04 :
1132 CI
- 0.000Ef00 0.000Ef00 1 0.000Ef00 0.000Ef00 1133 CI
- 0.000E400
- 0.000Ef00 : 0.161E-04 : 0.245E-03 :.
1134 CI
- 0.000Ef00 1 0.000Ef00 : 0.000E400 : 0.000Ef00 ;
1135
- CI
- 0.000Ef00 : 0.000Ef00
-0.000Ef00 : 0.000E+00 :
ENTER C C J TO ERASE SCREEN AND CONTINUE :
C
PAGE 4 0F 5 SITE: LIMERICK UNIT
- U1 U?ER: MART DATE* 08/26/93 08:03 EFFLUENT AND WASTE DISPOSAL REPORT LIDUID EFFLUENTS FOR RELEASE POINT:
1 LIQUID RAD WASTE DISCHARGE TO SCHUYLKILL RIVER j
CONTINUOUS MODE BATCH MODE j
NUCLIDES
- UNITS : QUARTER :
QUARTER GUARTER QUARTER
)
- RELEASED :
1 2
1 2
i LIDUID EFFLUENTS (CONTD) j CS134
- CI
- 0.000Ef00 0.000Ef00 : 0.785E-03 : 0.121E-02 :
- CS136 CI
- 0.000Ef00 : 0.000E400 : 0.000Ef00 0.000Ef00 :
l CS137 CI
- 0.000E400 : 0.000Ef00 : 0.210E-02 : 0.381E-02
- . CS138 CI
- 0.000Ef00 : 0.000E400 : 0.000E400 : 0.000Ef00 :
- BA139
- CI
- 0.000Ef00 : 0.000E400 0.000Ef00 : 0.000Ef00 :
FA140 CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
PA141 CI
- 0.000EiOO : 0.000Ef00 : 0.000EiOO : 0.000Ef00 :
PA142 CI
- 0.000E400 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :.
LA140 CI
- 0.000Ef00 : 0.000Ef00 : 0.934E-03 : 0.151E-03 :
LA142
- CI
- 0.000Ef00 : 0.000Ef00 : 0.000EiOO._: 0.000Ef00 :
- - CE141
- CI
- 0.000E400
- 0.000E400 0.463E-03 : 0.499E-05 :.
CE143
': CI
- 0.000E400 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
- CE144
- CI
- 0.000Ef00 0.000Ef00 : 0.000E-03 : 0.102E-04 :
PR143
- CI
- 0.000E400 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00
- PR144
- CI:
- 0.000E400 : 0.000Ef00 0.000E400 : 0.000EiOO :
ND147
- CI
- 0.000Ef00 1 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
AS76
- CI
- 0.000Ef00 : 0.000Ef00 0.194E-03 : 0.325E-05 :
W197
- CI
- 0.000Ef00 : 0.000EiOO
- 0.000Ef00': 0.339E-04 :
ENTER E C 3 TO ERASE SCREEN AND CONTINUE :
C
PAGE 5 0F 5 SITE: LIMERICK UNIT: U1 USER: MART DATE: 08/26/93 08:04 EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS FOR RELEASE FOINT:
1 LIQUID RAD WASTE DISCHARGE TO SCHUYLKILL RIVER CONTINUOUS MODE DATCH MODE NUCLIDES
- UNITS :
QUARTER QUARTER GUARTER QUARTER
- RELEAEED :
1 2
1 2
LIQUID EFFLUENTS (CONTD)
- NONE CI
- 0.000Ef00 : 0.000Ef00 : 0.000Ef00 : 0.000Ef00 :
TOTAL FOR :
FERIDD CI
- 0.000Ef00 ; 0.000Ef00 : 0.783E+01 : 0.453Ef01 :
(ABOVE)
XE-133 CI
- 0.000Ef00 : 0.000Ef00 : 0.115E-01 : 0.380E-01 :
XE-135 CI
- 0.000Ef00 : 0.000Ef00 : 0.12EE-01 : 0.24BE-01 :
i I
II.
TABLES C.
SOLID WASTE DISPOSITION REPORT January 1, 1993 to June 30, 1993 a
.p:
PAGE 10F 5 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS PERIOD 01/01/93 TO 06/30/93 A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (NOT 1RRADIATED FUEL)
- 1. TYPE OF WASTE UNIT 6 - MONTH ESTIMATE TOTAL PERIOD ERROR %
- a. SPENT RESINS, FILTERS SLUDGES, m(3) 8.54E + 01 EVAPORATOR BOTTOMS, ETC.
Ci 3.06E + 02 2.50E+ 01 (PROCESS - DEWATERED )
- b. COMPRESSIBLE WASTE, m(3) 2.55E +01 CONTAM!NATED EQUIPMENT, ETC.
Ci 8.59E-01 2.50E + 01 (PROCESS - COMPACTED )
- c. IRRADIATED COMPONENTS, CONTROL m(3) 0.00E + 00 RODS, ETC.
Ci 0.00E+ 00 0.00E + 00
- d. OTHER (ASH FROM INCINERATION) m(3) 9.88E-01 Ci 2.27E-01 2.50E+ 01 35 TYPE A LSA RESIN SHIPMENTS FROM LIMERICK 14 TYPE A LSA DAW SHIPMENTS FROM LIMERICK 4 EXEMPT QUANTITY GREEN IS CLEAN SHIPMENTS FROM LIMERICK
~
m
1 l
l 3e=c =
Dw O
mu r YYYYYYYYYYYYYYYYYYYYYYYYYYYYYYYYYYYYY Y
A
~ $; 5 8888888888888888888888888888888888888 8 c E 0060d000606d0006600000000000000000000 d
~a c
.c f a=
z e oc Jw
=<
2c 0_ 8888888888888888888888888888888888888 8
?k [~
+
+++++++++++++++++++++++++++++++++++++
3>L WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W
E 8888388888888888888888888888888888888 8 4
o 00606600006dd000600006d6d6dd000060600 O
=
2 o
a a
W D<
r
~
- 3
_aoc
=w i; d
&o 3
h$ $ $$$$$$$!$$$$$$$$$$$$$$$$$$$$$$$$!$$$8 $
3 doo6odo666666666666666666666066666666 o
.c a=
Ec f ac 2 C Q-
?%
8888888888888888888888888888888888888 8
~
E l> $
++++++++++++++++++++++++* ++++++++++++
+
'L WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW W
E" E
8888888888888888888888888888888888888 8 C
dddOOddOdddOOOOOddOdOOOdddOdodddOdddd d
W0 0
=
W s
y ea O
+
a N
O 3C W
O 2 a
p aC :
evnONCOOOe OOOOOOOOOOOOOOOOOOOOOOOOOO O
g _C 2 g[
-g e
O Nn e
c.c f c e=
?=
wc aC a-4c _e O Z C Q~ 5855855585588888888888888888888888888 8 z ?i
++++
++ i+ i + +
si++++i++++++++++i++++++i
+
c 3> [
,C ' '
~
WWWWWWWWWWWWWWW****WWWWWWWWWWWWWWWWWW W
f 808"888 88?88*588858888888888~8888880 8 a
o d e d w' d a 6 6 N n d o n e d d O n d 60666666dKO66066a 6 a
E w:
W e 3 i
5 C 3 6
4,.a
-a w
< 3
~
J o
2 w
2 y
5 n-wavee NQ-n O P i,
n m
n v w w a n n e g u, g g e n
~.,
n i
W
=
c a., w *o mine,i,i e
n no Oe m
o N
c,,
M oi o o _, c o w m o e Z : 0 2 < N E O _, W Z Z Z o o O M L E E c o < < w X oga nc m
u----uwu s 'm-co--gen o
e w
v e,
i o
e y
i s i s e s i s i i i L
- a n
n, aeonnaooEEEEew &
i i i s i i
e 1 e a.
t y
e e oo e. tSn 3
o 4
K e
w 4
g
l PAGE 3 OF 5 l
CATEGORY u - ORY COMPRESS &SW WAGTE.
CAT EGORY C - lHRADIATED REACIOR OR POOL CATEGORY O - OTHER (ASH FROM INC(NERATION)
CONTAMINATED EOuiPMENT. ETC.
COMPONENTS j
ISOTOPE CLA65 A ACTNiTY (Co
% A6UNDAP.CE CLA5S C ACIWsTY (Co
% ABUNDANCE CLASS A ACTMTY #C.)
% ABUNDANCE Zn-65 1.79 E -01 20.84 %
OmE + 00 0 00 %
4.75E-02 2095%
Cr-51 2EE-01 2678%
0 00E+ 00 0.00 %
6.05E-02 26 68 %
Cs-137 1.41 E- 02 1.64 %
0 00E + 00 0.00 %
3.74 E-03 1 65 %
Cs-134 0 00E + 00 0.00 %
0 00E + 00 0 00 %
0.00 E + 00 om%
l-131 0.00E + 00 0 03 %
0 00E + 00 0 00 %
0.00E + 00 0 00 %
Co-60 197 E -01 2204%
0 00E + 00 0 00 %
5 21E-02 2297%
Co-58 3.42 E - 02 3 96 %
0 00E,00 0.00 %
9.10E- 03 401%
{
Fe-55 1.06 E - 01 12.34 %
003E+00 0.00 %
2.75E-02 12.13%
Sr -89 0 00E + 00 0 00 %
0 00E + 00 om%
0.00E + 00 0 00 %
C-14 0 00E + 00 om%
0COE+00 0.00 %
0.00E + 00 cm%
Mn-54 7.42E-02 8 f4%
0 00E + 00 0C0%
1.06 E-02 8.73 %
Nb-95 0 00E + 00 0 00 %
0 00E + 00 0 00 %
0 00E + 00 0m%
H-3 OmE + 00 0.00 %
0 00E + 00 0.00 %
0.00E t 00 0m%
Da/La-140 0.00E + 00 0 00 %
0 00E + 00 0 00 %
0 00E + 00 0 00 %
Ni-63 1.44 E-02 1.68 %
0 COE + 00 0C0%
3ME-03 t.69 %
A0- 110 m 0 00E + 00 0.00 %
0 00E + 00 0 00 %
0.00E + 00 0 00 %
2r-95 0 00E +'X) 0 00 %
0.00E + 00 02%
0 00E + 00 0 00 %
P-32 0 00E + 00 02%
0 00E,00 0.00 %
0 00E,00 0 00 %
St-so OEE + 00 0 00 %
0 00 E + 00 Om%
O N E+00 Om%
l-129 0 00E + 00 0 00 %
0 00E,00 0 00 %
0 00E + 00 0 00 %
Tc-G9 0 00E + 00 0 00 %
0 COE + 00 0 00 %
0 00E + 00 0 00 %
N b-94 0 00E + 00 0 03 %
0 00E + 00 0 00 %
0 00E + 00 0 00 %
Ni-59 0 00E + 00 0 00 %
0 03E + 00 0 00 %
0 00E + 00 0 00 %
Np-237 0.00E + 00 0 00 %
O ccE + 00 o cc%
0 00E + 00 O Cc%
Ce -141 0 00E + 00 0.00 %
0.00 E + 00 cm%
0.00 E + 00 0.00 %
Co-144 0.00 E + 00 0 00 %
0.00 E + 00 0 00 %
0.00E + 00 0 00 %
Sb-125 100 E-02 1.16 %
0 00E + 00 0.00 %
2.70E -03 1.19 %
Gb-124 0 00E+ 00 0 00 %
0.00E + 00 0 00 %
0 00E+00 0 00 %
Pu-238 0 00E + 00 0 00 %
0 'CE + 00 0 00 %
0.00E + 00 0 00 %
Pu-239 omE+00 0 00 %
0 00E + 00 0m%
0 00E + 00 0 00 %
Pu-241 ONE+00 0 00 %
0 00E + 00 cm%
O m E+00 0 00 %
Cm-242 O mE + 00 0 00 %
0 00E + 00 0 00 %
0 00E + 00 0 00 %
Cm-243 0 00E + 00 0 00 %
0 00E + 00 0 00 %
0 00E +00 0 00 %
Am-241 0 00E + 00 0 00 %
0 00E + 00 O CO%
ONE + 00 02%
Am-243 0 00E + 00 0 00 %
0 00E + 00 0 00 %
0 00E+ 00 0 00 %
Fe-59 0 00E +00 0C0%
0 00E + 00 0 C0%
0.00 E + 00 0 00 %
TOTALS 850E-01 100 00%
0 00E,00 0 00 %
2 27E-01 100cc %
ACTN.TY.5 ESTNAIED t
PAGE 4 OF 5
- 3. SOLIDWASTE DISPOSITION l
NUMBER OF SHIPMENTS MODE OF TRANSPORTATION DESTINATION l
15 TRUCK LIMERICK TO BARNWELL 46 TRUCK SEG TO BARNWELL '
6 TRUCK QUADREX TO BARNWELL l
4 I
PAGE 5 OF 5
^l B. IRRADIATED FUEL SHIPMENTS (DISPOSITION)
NUMBER OF SHIPMENTS MODE OF TRANSPORTATION DESTINATION NONE N/A N/A
-l 1
COMMENTS:
31 SHIPMENTS FROM LIMERICK TO SEG FOR PROCESSING 7 SHIPMENTS FROM LIMERICK TO QUADREX FOR PROCESSING NO SOLIDIFICATION SHIPMENTS WERE MADE.
THE'PCP WAS NOT CHANGED DURING THIS PERIOD.
^
II. BTTACHMENTS A.
SUPPLEMENTAL INFORMATION Facility: Limerick Generating Station - Units 1 and 2 License : NPF-39 (Unit 1) and NPF-85 (Unit 2) 1.
Regulatory Limits (Technical Specification Limits)
A.
Noble Gases:
1.
5 500 mRems/yr - total body
" instantaneous" limits 5 3000 mRems/yr - skin per Tech Spec 3.11.2.1 and ODCM Control 3.3.2 2.
$ 10 mRads - air gamma
- quarterly air dose limits 5 20 mRads - air beta per Tech Spec 3.11.2.2 and ODCM Control 3.3.3 3.
5 20 mRads - air gamma
_ yearly air dose limits
$ 40 mRads - air beta per Tech Spec. 3.11.2.2 and ODCM Control 3.1.3 B.
Iodines, tritium, particulates with half life > 8 davs:
1.
5 1500 mRens/yr - any organ
" instantaneous" limits (inhalation path) per Tech Spec. 3.11.2.1 and ODCM Control 3.3.2 2.
$ 15 mRems - any organ
- quarterly dose limits per Tech Spec. 3.11.2.3 and ODCM Control 3.3.4 3.
$ 30 mRems - any organ
- yearly dose limits per Tech. Spec. 3.11. 2. 3 and ODCM Control 3.3.4 C.
Licaid Effluents:
1.
Concentration 5 10CFR20
" instantaneous" limits Appendix B, Table II, Col.2 per Tech. Spec. 3.11.1.1 and ODCM Control 3.2.2 2.
5 3 mRems - total body
- quarterly dose limits per 5 10 mRens - any organ Tech. Spec. 3.11.1.2 and ODCM Control 3.2.3 3.
5 6 mRems - total body
- yearly dose limits per 5 20 mRems - any organ Tech. Spec. 3.11.1.2 and ODCM Control 3.2.3 2.
Maximum Permissible Concentrations Per LGS ODCM Control 3.2.2, MPCs are not used to calculate permissible release rates and concentrations for gaseous releases. Tne MPCs specified in 10CFR20, Appendix B, Table II, Column 2
for identified nuclides are used to calculate permissible release rates and concentrations for liquid releases.
{
3.
Averace Enercy l
Based on gaseous effluent releases for the report period, average beta energy is 0.300 MeV and average gamma energy is 0.494 MeV.
4.
Measurements and Acoroximations of Total Radioactivity A.
Fission and Activation Gases The method used is the Canberra Series 90 Counting System; GS - Gas Marinelli.
B.
Iodine:
The method used is the Canbcrra Series 90 Counting System; CH - Charcoal Cartridge.
C.
Particulate:
The method used is the Canberra Series 90 Counting System; PT - Air Particulate Sample, 47 mm filter.
D.
Licuid Effluents:
The method used is the Canberra 9eries 90 Counting System and the Radwaste Liquid Discharge Pre-Release Method with a 3.5 liter Marinelli.
5.
Batch Releases A.
Liauid Q1 22
- of Batch Releases:
192 86 Total time period for batch releases, 14,067 5793 Maximum time period for a batch release 122 130 Avcrage time period for batch release, 73.27 67.36 Minimum time period for a batch release, 55 50 Average stream flow (Schuylkill River) 1.37E6 1.57E6 during periods of release of effluents into a flowing stream, gpm.
B.
Gaseous
- of Batch Releases:
10 0
Total time period for batch releases, 8100 0
Maximum time period for a batch release, 1800 0
Average time period for batch release, 810 0
Minimum time period for a batch release, 60 0
- = Minutee
6.
Abnormal Releases A.
Licuid None i
B.
Gaseous
'None i
7.
Description of LGS Effluent Release Points Release Point 1 = North Stack, Common Release Point 2 = South Stack, Unit 1
{
Release Point 3 = South Stack, Unit 2 Release Point 4 = Hot Maintenance Shop Liquid Release Point = LGS Liquid Radwaste Discharge 8.
Descrintion of LGS Liould Dose Receptors Receptor 1 = LGS Liquid Radwaste Discharge Point Receptor 2 = Citizens Home Water Company Receptor 3 = Phoenixville Water Company Receptor 4 = Philadelphia Suburban Water Company Receptor 5 = City of Philadelphia crew Course l
i 1
I I
i i
i
6.
Abnornal Releases A.
Liauld None i
B.
Gaseous None 7.
Description of LGS Effluent Release Points Release Point 1 = North Stack, Common Release Point 2 = South Stack, Unit 1 Release Point 3 = South Stack, Unit 2 Release Point 4 = Hot Maintenance Shop l
Liquid Release Point = LGS Liquid Radwaste Discharge l
8.
Description of LGS Licuid Dose Recentors Receptor 1 = LGS Liquid Radwaste Discharge Point Receptor 2 = Citizens Home Water Company Receptor 3 = Phoenixville Water Company i
t Receptor 4 = Philadelphia Suburban Water Company l
Receptor 5 = City of Philadelphia Crew Course u
-