ML20054C539
| ML20054C539 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 04/13/1982 |
| From: | Fay C WISCONSIN ELECTRIC POWER CO. |
| To: | Harold Denton Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19268D237 | List: |
| References | |
| TAC-46694, TAC-46695, NUDOCS 8204210283 | |
| Download: ML20054C539 (2) | |
Text
.k l
ATTACHMENT TO BE WITHHELD FROM PUBLIC DISCLOSURE CONTAINS PROPRIETARY MATERIAL
. m.
l Wisconsin Electnc eam cowa 231 W. MICHIGAN, P.O. BOX 2046, MILWAUKEE, WI 53201 April 13, 1982 Mr. H.
R.
Denton, Director Office of Nuclear Reactor Regulation U.
S. NUCLEAR REGULATORY COMMISSION Washington, D.
C.
20555 Attention:
Mr.
R.
A. Clark, Chief Operating Reactors, Branch 3 Gentlemen:
DOCKET NOS. 50-266 AND 50-301 STEAM GENERATOR SLEEVING REPAIR REPORT, REVISION 1 POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 By letter dated March 11, 1982, Wisconsin Liectric Power Company, Licensee for the Point Beach Nuclear Plant, Units 1 and 2, transmitted to the Nuclear Regulatory Commission the " Point Beach Steam Generator Sleeving Report, WCAP-9960, Revision 1 (Proprietary) ", in support of Licensee's July 2, 1981 license amendment application for changes to the Technical Specifications which would permit repair of defective steam generator tubes by sleeving.
Enclosed are 20 copies of a reprint of the original document submitted on March 11, 1982.
As explained in the March 19, 1982 letter to the Staff from counsel for Westinghouse Electric Corporation
(" Westinghouse"), the material considered proprietary was marked incompletely in the original document.
The enclosed reprint completely marks such information.
In addition, the reprint corrects one typographical error in the original document; on page 6.32, at line 3 of Issue 2, the word " percent" in the original document has been corrected to " pounds" in the reprint.
In all other respects, the reprint is identical to the original document.
Like the original document, the enclosed reprint contains certain information which.is proprietary to Westinghouse.
The proprietary information has been identified by brackets.
In conformance with the requirements of 10 CFR Section 2.790 of the 8204210283 820416 PDR ADOCK 05000266 P
pop
C Mr.
H.
R. Denton April 13, 1982 Commission's regulations, we have enclosed herewith an application for withholding this proprietary material from public disclosure which references previous affidavits from Mr. Robert Wiesemann in support of the application.
The referenced affidavits set forth the basis upon which this information should be withheld from public disclosure.
Very truly yours,
,/
g, b ff Assistant Vice President C. W.
Fay Enclosures (20)
Copies to NRC Resident Inspector ASLB Service List Subscribed and sworn to before me this 132ML day of April 1982.
M 4Wm Y==-:=w Notary (Ublic, State of Wisconsin My Commission expires %_ / /187.
O