ML20050B833
| ML20050B833 | |
| Person / Time | |
|---|---|
| Site: | Fort Calhoun |
| Issue date: | 04/02/1982 |
| From: | William Jones OMAHA PUBLIC POWER DISTRICT |
| To: | Clark R Office of Nuclear Reactor Regulation |
| References | |
| LIC-82-143, NUDOCS 8204070465 | |
| Download: ML20050B833 (36) | |
Text
r s
=c Omaha Public Power District 1623 HARNEY 8 O M A H A, esEBRASMA 68102 8 TELEPHONE 536 4000 AREA CODE 402 April 2,1982 LIC-82-143 m
o QN Mr. Robert A. Clark, Chief CECMTD U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation 9, "APR S 198 N $
T*[$"":a
- N Division of Licensing Operating Reactors Branch No. 3 E
f Washington, D.C.
20555 h,
I W
Reference:
Docket No. 50-285
~_
Dear Mr. Clark:
Subject:
Environmental Qualification of Equipment Installed in Response to TMI Requirements Omaha Public Power District's letter to the Commission dated February 1, 1982 stated that additional information on the subject issue would be provided within sixty (60) days.
The additional information is attached.
An update on other open issues on TMI equipment is included. Also included is a revised page 2 of Enclosure 13 of the District's quali-fication package. Enclosure 13 was revised to indicate that the Dis-trict is presently verifying the documentation of qualification values for 100 day doses to the new accident monitoring equipment. The attached SCEWS and revised Enclosure 13 should be incorporated into the District's qualification package transmitted to the Commission by letter dated August 26, 1981.
Sincerely,
/
Y0^ J W. C.
nes Divisi h Manager Product' ion Operations Attachments cc:
LeBoeuf, Lamb, Leiby & MacRae 1333 New Hampshire Avenue, N.W.
Washington, D.C.
20036 t
l fo4+
6 9 8204070465 820402 PDR ADOCK 05000 P
t 8
ENCLOSURE OUTSTANDING EQUIPMENT QUALIFICATION INFORMATION FROM DISTRICT'S LETTER DATED FEBRUARY 1, 1982 Cable and Splices Used With TMI Modifications The qualification documentation for the Raychem splices that were used in these TMI Action Item modifications is complete.
The inter-connecting cables that were used in these TMI Action Item modifications are CQE qualified cables, as specified by Class 1E equipment qualifi-cation (IEEE Standard 323-1974 and IEEE Standard 383). The SCEWS for both cables and splices are attached.
Auxiliary Feedwater Modifications The qualification documentation for the Foxboro transmitters has not been supplied by the vendor as of yet.
When the test results are obtained, the SCEWS will be submitted. The qualification documentation for the ASCO solenoids is complete and the SCEWS are included with this letter. The qualification documentation for the Namco limit switches is complete. The SCEWS are included with this letter.
Reactor Coolant System Vents Modification The SCEWS for the Target Rock solenoid valves used in this modifi-cation was previously submitted.
The SCEWS for the Conax penetrations will be providad by May 1,1982, as detailed in the District's letter dated March 25, 1982.
Accident Monitoring Instrumentation The SCEWS and a copy of the test document for the Comsip hydrogen analyzer are complete and included with this letter.
The qualification testing documentation is complete and on file at the Fort Calhoun Station for the Valcor isolation valves used in this accident monitoring instrumentation modification.
The qualification testing meets the requirements of IEEE 323-1974.
The SCEWS will be submitted by May 1, 1982.
The SCEWS for the ASCO solenoids are complete and included with this letter.
The SCEWS for the Victorcen high range containment radiation area monitor is complete and included with this letter.
l Pressurizer Level Indication j
The qualification documentation for the Foxboro transmitters has not been supplied by the vendor as of yet.
When the test results are obtained, the SCEWS will be submitted.
I
' Containment Sump Water Level Modification The qualification documentation for the GEMS transmitters has not been completed by the test facility.
Wyle Labs is in the process of completing final documentation and once obtained by the District the SCEWS will be provided.
Containment Wide Range Pressure Monitor The containment pressure monitor uses the same Foxboro transmitter discussed above for pressurizer level and auxiliary feedwater modifi-cations.
SCEWS will be provided once the District rec"ives the test documentation.
Safety Injection Pump Leakage Detection Syst,:qn The SI pump leakage detection system uses the same GEMS transmitters as the containment sump level indicator; therefore, the same information as discussed above applies.
1 O
e
+
' Enclosure 13 Outstanding Items (Continued)
.l
- 10. The District plans ?.o complete testing of the Fisher 304 limit switch by June 30, 1982.
11.* The limit switches $nd Valcor solenoid valves in containment were replaced with environmentally qualified components during the 1981 refueling outage.
12.* The solenoid valves and limit switches in the auxiliary building were replaced with environmentally qualified components during the 1981 refueling outage.
- 13. TE 866 and TE 867 will be replaced during the first refueling outage after receipt of qualified parts.
- 14. Qualified Safety Related Equipment will be identified and marked with orange in the control room and operator training will be completed by June 30, 1982.
- 15. Conax Corporation has verified that the concentration of boron used in the chemical concentration qualification of their Conax seals was an acceptable 3000 parts per million.
Conax Corporation has also confirmed in the same letter that their seals are qualified for a design life of 40 years (reference Conax letter from W. C.
Frederick to R. F. Mehaffey (OPPD) dated February 5,1982).
The SCEWS have been revised to refle:.t this information and will be provided to the Commission by May 1, 1982.
16.
The District is in the process of verifying the 100 day dose qualification documentation for accident monitoring modification items.
- These items are complete.
Fccility: Fcrt Calbrun 1 Dock:t No.: 50-285 S-200 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTANP CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation system: Containment Hydrogen Operating 100 days P( st Purge System Time Note 1 Accident 1
3 Type Test NONE Item No.: VA-81A & VA-81B Tempera-ture *F N/A N/A N/A N/A N/A NONE Component: Hydrogen Analyzers Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: COMSIP Relative Model No.: Delphi IV Hydrogen Humidity %
N/A N/A N/A N/A N/A NONE Analyzer Function: Containment Atmosphere
. Chemical Hydrogen Analyzers Spray N/A f
N/A N/A N/A N/A NONE j
cn h;
Accuracy - Spec: Note 2 Note 3
'i Demon:
Radiation 8x10 R 1x10 R 5
6 2
3 Type Test NONE Service: Determine % H2 con-concentration in containment Location: Roor 59 Aging N/A 5-10 yrs' N/A 3
Type Test NONE ilooo Level Elev: N/A Submer-Type Test Above' Flood Level: Yes No gence N/A N/A N/A N/A N/A NONE!
Dacumenta'tlon
References:
Notes:
- 1) NUREG 0737.
- 1) Required to operate during and 100 days after DBA
- 2) " Implementation hethods and Schedules for
- 2) IE Bulletin 79-01B submittal Enclosure #12 NURES 0578" Section 2.1.6B page 18, figure
- 3) See Enclosure 13, Item 16
~
4.2-3 (December 1979) u,
- 3
- 3) COMSIP, Inc. " Test Report IEEE-323-1974 A'
j,.,
l#)
Qualification of Delphi IV Hydrogen / nalyzer os
~
[.Piesent Qualification
.s.
I 4574/b-8/s
l
, Facility: Tert Calh:un 1 i
- Dock t N3.
50-285 i
C-26J SYSTcM COMPONENT EVALUATON WORK SHEET
)
o c
ENVIRONMENT '/
.DOCUMENTATON REF.
QUALIFI-OUTSTAND *
'J -
CATION ING fj.,
EQUIPMENT DESCRIPTION Specifi-Qualif '
Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation system:. containment Hydrogen Operating 2
3 Type Test NONE Analyzer System Time Note l' Note 3 Item No.: HCV-883C, 883D, 883E, 883F, S83G, 883H, HCV-820C, 820D Tempera-NONE 820E, 820F,'820G, 820H ture *F 305*F 346*F 1
3 Type Test Component:. Electric Solenoid vv ressure PSIg 60 PSIg 110 PSIg i
3 Type Test NONE Manufacturer: ASCO Relative Model No.:.X206-381-6RF Humidity %
100%
,100%
1 3
Type Test NONE r
Function:' H2 Analyzer. con-Chemical 1700 ppm 3000 ppm l
tainment sample valve.
Spray Boron Boron PH 10 1
3 Type Test NONE cn
~.
h2 Accuracy Spec: N/A Note 4
,7 8
j3 Demon: 'N/A-Radiation 1.6x.10 R 2x10 R N/A
-3 Type Test, NONE l
Service:
~
Location: Containment Aging N/A 10 yr N/A 3
Type Test NONE 11000 Level Elev:
1001.0' Submer-Above Flood Level. Yes gence N/A N/A N/A N/A N/A NONE vocumentation xeterences:
Notes:
- 1) IE Bulletin 79-01B submittal Enclosure #1.
- 1) Required to operate 100 days for after DBA, not required to
- 2) NUREG 0737 operated under normal operation.
3,
- 3) ASCO test report AQS 21678KR Rev. A
- 2) IE Bulletin 79-01B submittal,
- 3) Wear Agine - 40,000 operations at maximum operating pressure u,
73 differential and nominal voltage.
to
- 4) See Enclosure 13, item 16.
f03 Present Qualification IEEE 323-1974 4574/b-10/s
Fccility: Fart Calh:un 1 Docket Ns.: 50-285 C-300 SYSTEM COMPONENT EVALUATION WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAN6-CATION ING EQUIPMENT DESCRIPTION specifi-Qualif-Specifi _
Qualifi,,
METHOD ITEMS Parameter
- ation cation cation cation System: Ele-trical Equipment Operating Time
- ontinuous Continuous 1
2 Type Test NONE Item No.: N/A Tempera-s, ture *F 305*F 385*F 1
.2 Type Test NONE Component: Splices Pressure PSIg 50 PSIg
'6'6 PSIg 1
2 Type Te n NONE s
Manufacturer: Raychem Relative i
Model No.: Raychem Breakout Humidity %
100%
100%
1 2
Type, Test-NONE kits Function: Splices for Inter-Chemical 1700 ppm 6200 ppa g-
?
facing in all Systems Spray Boron Boron 1
2 Type Test NOhT t
Accuracy - Spec: N/A Worst Case 7
8 2x10 Rads 2.9x10 1
2 Type Test NONE Demon: N/A Radiation Service: All Systems Location: Containment Aging 40 yrs 40 yrs 1
2 Type Test NONE Flood Level Elev:
1000.9' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE' Documentation
References:
Nctes:
- 1) Enclosure #1.
- 2) Environmental Qualification Test Report of Raychem WCSF-N Nuclear In-Line Cable Splice Assemblies for Raychem Corporation 5/15/80 Present Qualification IEEE 323-1974 4574/d-1/s
_ _ ~ -..
_ _ _ ~. _ _ _. _. _ _. -.. _.. _ _. _. _ _ _ _ _
4 _ _
4 1
~
Fccility: Fort Colh un 1 Docket No.: 50-285 S-301 SYSTEM COMPONENT EVALUATION WORK SHEET
-ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION specifi-Qualif-Specifi-Qualifi-METHOD ITDRS Parameter cation cation cation cation System: Electrical Equipment Operating Time Continuous Continuous 2
1 Type Test NONE Iten No.: N/A Tempera-Rs 21 & 22 ture *F 109'F 385'F 2
1 Type Test NONE Component: Splices Pressure PSIg N/A 66 PSIg N/A 1
Type Test NONE Manufacturer: Raychem Relative Rm 21 & 22 Model No.: Raychem Breakout Humidity %
100%
100%
2 1
Type Test NONE kits.
Function: Splices for Inter-Chemical i
facing in all Systems Spray N/A N/A N/A 1
Type Test NONE j
t O
Accuracy - Spec: N/A L
Demon: N/A Radiatian Note 1 2.9x10s 3
1 Type Test NONE Service: All Systems Location: Balance of' Aux' Bldg Aging N/A N/A N/A N/A N/A N/A Flood Level Elev: N/A Submer-l j
Above Flood Level:
gence N/A N/A N/A N/A N/A N/A i
Documentation
References:
Notes:
I
- 1) Environmental Qualification Test Report
- 1) Rm-69 5
2.5x10 R j.
of Raychem WCSF-N Nuclear In-Line Cable Ras 21 & 22 - 7x10sR I
4x10sR Splice Assemblies for Raychem Corporation 5/15/80 Rm 13 5
- 2) Combustion Engineering Study " Evaluation of Fort Calhoun Rm 60 6x10 R 8
Safety Injection Pump Room Temperature following a loss Ra 59
- 8x10 R i
of coolant accident" See OPPD letter to the NRC dated 9/6/79.
l
- 3) " Implementation Methods and Schedules for NUREG-0578" Section 2.1.6b, Pages 16-19 Figures 4.2-1, 4.2, 4.2.3 & 4.2.4 (December 1979) i Present Qualification IEEE 323-1974
Fccility: Fort Colh un 1 Docket No.: 50-285 S-302 SYSTEM COMPONENT EVALUATION WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAN6-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation Syster: Electrical Equipment Operating Time Continuous Continuous 1
2 Type Test NONE Item No.: N/A Tempera-ture 'F 216*F 385'F 1
2 Type Test NONE Component: Splices Pressure PSIg 1.2 PSIg 66 PSIg 1
2 Type Test NONE Manufacturer: Raychem Relative Model No.: Raychem Breakout Humidity %
100%
100%
1 2
Type Test NONE kits Function: Splices for Inter-Chemical facing in all Systems Spray N/A N/A N/A N/A N/A NONE 3
hh Accuracy - Spec: N/A Demon: N/A Radiation
.N/A N/A N/A N/A N/A NONE Service: All Systems Location: Room 81 Aging N/A N/A N/A N/A N/A NONE Flood Level Elev:
1037.4' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Reference Enclosure #2.
- 2) Environmental Qualification Test Report of Raychem WCSF-N Nuclear In-Line Cable Splice Assemblies for Raychem Corporation 5/15/80 Present Qualification IEEE 323-1974 4574/d-2/s
Fccility: Fcrt Colhoun 1 Dock;t No.: 50-285 S-303 SYSTEM COMPONENT EVALUATION WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OITfSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Electrical Equipment Operating Time Continuous Continuous 1
3 Type Test NONE Item No.: N/A Tempera-Rm 21 & 22 ture *F 109'F 346*F 1
3 Type Test NONE Component: Cable Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: Rockbestos Relative Rm 21 & 22 Model No.: Fire Wall III Humidity %
100%
100%
1 3
Type Test NONE Function: Interconnecting -
Chemical
[{
cables for all Systems Spray N/A N/A N/A N/A N/A NONE us Accuracy - Spec: N/A Demon: N/A Radiation Note 1 2x108 2
3 Type Test NONE Service: All Systems Location: Balance of Aux Bldg Aging N/A N/A N/A N/A N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
5
- 1) Combustion Engineering Study " Evaluation of Fort Calhoun
- 1) Rm 69
- 2.5x10 R 6
Safety Injection Pump Room Temperature following a Loss Rms 21 & 22 - 7x10 R 8
of Coolant Accident" See OPPD letter to the NRC dated Rm 13
- 4x10 R 5
9/6/79.
Rm 60
- 6x10 R 5
- 2) " Implementation Methods and Schedules for NUREG-0578" Section Rm 59
- 8x10 R 2.1.6b, Pages 16-19 Figures 4.2-1, 4.2-2, 4.2-3 & 4.2-4 (December 1979)
- 3) Qualification of Fire Wall III, Class 1E Electric Cables 2/1/77 Present Qualification IEEE 323-1974
Fccility: Fort Calh:un 1 Dock:t Ns.: 50-285 C-250 SYSTEM COMPONENT EVALUATION WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OLTISTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Electrical Equipment Operating Time Continuous Continuous 1
2 Type Test NONE Item No.: N/A Tempera-ture *F 305*F 346*F 1
2 Type Test NONE Component: Cables Pressure PSIg 60 PSIg 113 PSIg 1
2 Type Test NONE Manufacturer: Rockbestos Relative Model No.: Fire Wall III Humidity %
100%
100%
1 2
Type Test NONE Function: Interconnecting Chemical 1700 ppm 3000 ppm
?
Cables for all Systems Spray Boron Boron 1
2 Type Test NONE Accuracy - Spec: N/A worst case 2x10 Rads 2x10s 1
2 Type Test NONE 7
Demon: N/A Radiation Service: All Systems Location: Room 81 Aging 40 yrs 40 yrs 1
2 Type Test NONE Flood Level Elev:
1000.9' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Enclosure #1.
- 2) Qualification of Fire Wall III Class IE Electric Cable 2/1/77 Present Qualification IEEE 323-1974 4574/d-4/s
Fccility: Fcrt Calh;un 1 Dot:ket No.: 50-285 S-304 SYSTEM COMPONENT EVALUATION 10RK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OtrfSTAND-CATION ING EQUIPMENT DESCRIPTION specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter ration cation cation cation System: Electrical Equipment Operating Time
- entinuous Continuous 1
2 Type Test N0hT Item No.: N/A Tempera-ture *F 216*F 346*F 1
2 Type Test NONE Component: Cables Pressure PSIg 1.2 PSIg 113 PSIg 1
2 Type Test NONE Manufacturer: Rockbestos Relative Model No.: Fire Wall III Humidity %
100%
100%
1 2
Tyne Test NONE Function: Interconnecting unemical
?
Cables for all Systems Spray N/A N/A N/A N/A N/A NONE 5
o Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service:.All Systems
' Location: Room 81 Aging N/A N/A N/A N/A N/A NONE Flood Level Elev:
1037.4' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
I
- 1) Enclosure #2.
- 2) Qualification of Fire Wall III Class IE Electric Cable 2/1/77 Present Qualification IEEE 323-1974 4574/d-6/s
Fccility: Fort Colh un 1 s
Dock t N2.:
50-285 C-200 SYSTEM COMPONENT EVALUATON WRK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTANDJ CATION ING g
EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Radiation Monitoring Operating Time Note 1 Note 2 2
3 Type Test NONE Item No.: RM-091A RM-091B Tempera-ture *F 305*F 357*F 1
3 Type Test NONE Component: Detector Pressure PSIg 60 PSIg Note 2 1
3 Type Test NONE Manufacturer: Victoreen Relative Model No.: 878 Humidity %
100%
100%
1 3
Type Test NONE Function: High range containment Chemical Radiation Area Monitor Spray 1700 ppm 3000 ppm 1
3 Type Test NONE
- T' 2"
Accuracy - Spec:
Note 3 3
8 7
j!
Demon:
Radiation 1x10 R 1x10 R 1
3 Type Test NONE 1
Service:
Location: Containment Aging N/A 40 yrs N/A 3
Type Test NONE Flood Level Elev:
1001.0' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) IE Bulletin 79-01B submittal Enclosure #1.
- 1) During and continuously after DBA.
- 2) NUREG 0737
- 2) 1 year under accident environment.
7,
- 3) Qualification Type Test Data Report for
- 3) See Enclosure 13 item 16.
Class 1E Victoreen High Range Containment u,
?3 Radiation Area Monitor System T
! R3 Present Qualification IEEE 323 1974 4574/b-9/s
Fccility: Fert Calh:un 1 Dock 2t No.: 50-285 S-6 I
SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OtTTSTAND-<
CATION ING j;
EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Note 1 1000 hrs Note 1 2
Type Test NONE Item No.: HCV-1107B & 1108B t
Tempera-I l1 ture *F 216*F 346*F 1
2 Type Test NONE
.I Component: Solenoid Valve #1 Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE l'
Manufacturer: ASCO Relative Model No.: NP 8320A175E Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical St/ Gen RC-2A & RC-2B Aux FW Spray N/A N/A N/A N/A NONE y'
inlet valves
-l Accuracy - Spec: N/A u)
Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation of Aux FW Lines Location: Room 81 Aging N/A 10 yrs N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE-Documentation
References:
Notes:
- 1) See Enclosure #2.
- 1) Valves are locked open and do not operate during an
- 2) ASCO Test Report Model AQS 21678/TR event.
12 Present Qualification 5;
'IEEE 323-1974 l~
4574/b-6/s l
Facility: Fort-Calh:un 1 Docket No.: 50-285 S-7 SYSTEM COMPONENT EVALUATON WORK SHEET 4
ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OITfSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating
' l.
Feedwater & Blowdown Time Note 1 1000 hrs Note 1 2
Type Test NONE Item No.: HCV-1107B & 1108B Tempera-qi i
ture *F 216*F 346*F 1
2 Type Test NONE
+
Component: Solenoid Valve #2 Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE-Manufacturer: ASCO
'f l-Relative Model No.: NP 8314C29E Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical i
St/ Gen RC-2A & RC-2B Aux IV Spray N/A N/A N/A N/A N/A NONE 7'
inlet valves
'l j
Accuracy - Spec: N/A j ' c)
Demon: N/A
' Radiation N/A N/A N/A N/A N/A NONE i
Service: Isolation of Aux FW Lines Location: Room 81 Aging N/A 10 yrs N/A 2
Type Test NONE l
Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE-i
.I i Documentation
References:
Notes:
1
- 1) See Enclosure #2.
- 1) Valves are locked open and do not operate during an l
'2) ASCO Test Report Model AQS 21678/TR event.
7a
.ro l
I Present Qualification
. no 23 IEEE 323-1974 lE2 oo BJ 4574/b-5/s l
l 1
~.
- - - ~ ~ - - - - - -,
r.-.
Fccility: Fort Celhoun 1 Dockct No.: 50-285 S-201 SYSTEM COMPONENT EVALUATON M)RK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAhP CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Intermitter t 1000 hrs.
1 2
Type Test NONE Item No.: FCV-1368, 1369 Tempera-ture *F 216*F 346*F 1
2 Type Test NONE Component: Solenoid Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test N0hT Manufacturer: ASCO Relative Model No.: NPC314C29E Ilumidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical Aux. Feedwater Valves Spray N/A N/A N/A N/A N/A NONE 9'
C Accuracy - Spec: N/A Demon: N/A Radiation N/A L'/A N/A N/A N/A NONE Service: Isolation of Aux.
Feedwater Line Location: Room 81 Aging N/A 10 yrs.
N/A 2
Type Test NONE Floodk.evelElev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Enclosue: #2.
- 2) ASCO Test Report Model AQS 21678/TR R
Present Qualification IEEE 323-1974 3
m 4574/b-7/s O
. ~ _. _.
Fecility: ; Fort Calhzun'1 Dock:t Ns.: 50-285 i
'S-200 SYSTEM COMPONENT EVALUATON WRK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OITTSTANDd CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System:. Steam Generator, Operating Feedwater & Blowdown Time Intermitte st 1000 hrs.
1 2
Type. Test NO"E
. Item No.: FCV-1368, 1369 Tempera-ture 'F 216'F 346*F 1
2 Type Test NONE Component: Soleno'id Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative l
4
'Model No.: NP8314C29E Humidity %
100%
100%
1 2
Type Test NONE t
Function: Valve Actuators for Chemical Aux. Feedwater Valves Spray N/A N/A N/A N/A N/A NONE
'. os g;
Accuracy - Spec: N/A Sj Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation & Control of Aux. Feedwater Lines Location: Room 81 Aging N/A 10 yrs.
N/A.
2 Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes ge'nce N/A N/A N/A N/A N/A NONE i
Documentation
References:
Notes:
- 1) Enclosure #2.
- 2) ASCO Test Report Model AQS 21678/TR i
t Present Qualification
~
- 3.
R C3 4574/b-4/s m
Fccility: Fert Calh:un 1 Dockat No.: 50-285 S-202 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OLTISTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-Fr! HOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Intermitte at 1000 hrs.
1 2
Type Test NONE Item No.: YCV-1045 Tempera-ture *F 216*F 346*F 1
2 Type Test NONE Component: Solenoid Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP8314C29E Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical Aux. Feedwater Valves Spray N/A N/A N/A N/A N/A NONE T
g; Accuracy - Spec: N/A Cj Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation & Control of Aux. Feedwater Line Location: Room 81 Aging N/A 10 yrs.
N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes ge'nce N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Enclosure #2.
- 2) ASCO Test Report Model AQS 21678/TR Present Qualification IEEE 323-1974 4574/b-2/s
Fccility: Fort Calhoun 1 j
Docket No.: 50-285 S-203 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIF1-OUTSTAND-l CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Intermitte:it 1000 hrs.
1 2
Type Test NONE Item No.: YCV-1045A, 1045B Tempera-ture *F 216*F 346*F 1
2 Type Test NONE Component: Sclenoid Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP8320A185V Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical Aux. Feedwater Valves Spray N/A N/A N/A N/A N/A NONE T
-l Accuracy - Spec: N/A E3 Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation & Control of Aux. Feedwater Line Location: Room 81 Aging N/A 10 yrs.
N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
{
- 1) Enclosure #2.
- 2) ASCO Test Report Model AQS 21678/TR Present Qualification IEEE 323-1974 4574/b-3/s 9
Fccility: Fort Calhsun 1 Dockat No.: 50-285 S-204 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTANDJ CATION ING EQUIPMENT Dr.SCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Continuous Continuou s 1
2 Type Test NONE Item No.: YCV-1045, YCV-1045A, YCV-1045B, FCV-1368, FCV-1369 Tempera-HCV-1107B, 1108B Solenoids #1&2 ture F 216*F 340 F 1
2 Type Test NONE Component: Limit Switch Pressure PSIg 1.2 PSIg 70 PSIg 1
2 Type Test NONE Manufacturer: NAMCO Relative Model No.: EA 180-11302 Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Position Chemical PH 10-11 Indicators Spray N/A Boron 1
2 Type Test NONE i
G Accuracy - Spec: N/A 8
S Demon: N/A Radiation N/A 2x4x10 R 1
2 Type Test NONE Service:
Location: Room 81 Aging N/A Note 2 Note 2 Note 2 Type Test NONE Flood Level Elev:
1037.4' Submer-Type Test
~
Above Flood Level: Yes gence Note 1 Note 1 N/A N/A Note 1 NONE Documentation
References:
Nctes:
- 1) Enclosure #2.
- 1) The switches were sealed and tested to 70 PSIg. The District
- 2) NAMCO Test Report Model EA180 9/5/78 considers them capable of withstanding submergence.
- o
- 2) Switches qualified for 40 years using NAMCO recommended Present Qualification maintenance. NAMCO letter dated 7/16/80.
a M
R H
4574/b-1/s 9
m s
_ _ _ _ = _..
9 Fecility: Fort Calhoun 1 Docket No.:
50-285 S-200 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation
. :sys tem: Containment Hydrogen Operating 100 days Pc st Purge System Time Note 1 Accident 1
3 Type Test NONE-Item No.: VA-81A & VA-81B Tempera-ture *F N/A N/A N/A N/A N/A NONE Component: Hydrogen Analyzers Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: COMSIP Relative Model No.: Delphi IV Hydrogen Humidity %
N/A N/A N/A N/A N/4 NONE Analyzer Function: Containment Atmosphere Chemical Hydrogen Analyzers Spray N/A N/A N/A N/A N/A NONE ig Accuracy - Spec: Note 2 Note 3 5
6
'1 Demon:
Radiation 8x10 R 1x10 R 2
3 Type Test NONE Service: Determine % H2 con-concentration in containment Location: Room 59 Aging N/A 5-10 yrs N/A 3
Type Test NONE 11000 Level Elev: N/A Submer-Type Test Above Flood Level: Yes No gence N/A N/A N/A N/A N/A NONE vocementation Meterences:
Notes:
- 1) NUREG 0737.
- 1) Required to operate during and 100 days after DBA
- 2) " Implementation Methods and Schedules for
- 2) IE Bulletin 79-01B submittal Enclosure #12 NUREG 0578" Section 2.1.6B page 18, fi ure
- 3) See Enclosure 13, Item 16 h
4.2-3 (December 1979) m
- 3) COMSIP, Inc. " Test Report IEEE-323-1974
,R Qualification of Delphi IV Hydtogen Analyzer Present Qualification IEEE 323-1974 4574/b4/s
_-.m.
Facility: Fort Calhoun l'
~Dockat No.: 50-285 C-26J I
SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-
- OUTSTAND, CATION ING EQUIPMENT DESCRIPTION Sperifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation system: containment Hydrogen Operating Analyzer System Time Note 1 Note 3 2
3 Type Test NONE Item No.: HCV-883C,'883D, 883E, 883F, 883G, 883H, HCV-820C, 820D Tempera-
--820E, 820F, 820G, 820H ture *F 305*F 346*F 1
3 Type Test NONE Component: Electric Solenoid vv Pressure i
~
PSIg 60 PSIg 110 PSIg 1
3 Type Test NONE Manufacturer: ASCO Relative Model No.: X206-381-6RF Humidity %
100%
100%
1 3
Type Test NONE l
t Function:-H 2 Analyzer con-Chemical 1700 ppm 3000 ppm tainment sample valve Spray Boron Boron PH : 0 1
3 Type Test NONE
'T' L
' hj Accuracy - Spec: 'N/A Note 4 j f3 Demon: N/A Radiation 1.6x.10 R 2x10sR N/A 3
Type Test NONE 7
Service:
Location: Containment Aging N/A 10 yrs N/A 3
Type Test NONE Flooa Level Elev:
1001.0' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A.
N/A NONE Locumentation Meterences:
Notes:
I
- 1) IE Bulletin 79-01B submittal Enclosure #1.
- 1) Required to operate 100 days for after DBA, not required to l
- 2) NUREG 0737 operated under normal operation.
i
- 3) ASCO test report.AQS 21678KR Rev. A
- 2) IE Bulletin 79-01B submittal.
- 3) Wear Agine - 40,000 operations at maximum operating pressure u,
73 differential and nominal voltage.
- 4) See Enclosure 13, item 16.
t lto R3 -
Present Qualification IEEE.323-1974 4574/b-10/s
.y.-,
Fccility: Fort Calhoun 1 Dock t No.:
50-285 C-300 SYSTEM COMPONENT EVALUATION WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION 3pecifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter
- ation cation cation cation System: Electrical Equipment Operating Time
- ontinuous Continuous 1
2 Type Test NONE Item No.: N/A Tempera-ture *F 305*F 385*F 1
2 Type Test NONE Component: Splices Pressure PSIg
$0 PSIg 66 PSIg 1
2 Type Test NONE Manufacturer: Raychem Relative Model No.: Raychem Breakout Humidity %
100%
100%
1 2
Type Test NONE kits Function: Splices for Inter-Chemical 1700 ppm 6200 ppm
?
facing in all Systems Spray Boron Boron 1
2 Type Test N0hI 8
7 Accuracy - Spec: N/A Worst Case 7
8 Demon: N/A Radiation 2x10 Rads 2.9x10 1
2 Type Test NONE Service: All Systems Location: Containment Aging 40 yrs 40 yrs 1
2 Type Test NONE Flood Level Elev:
1000.9' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Enclosure #1.
- 2) Environmental Qualification Test Report of Raychem WCSF-N Nuclear In-Line Cable Splice Assemblies for Raychem Corporation 5/15/80 Present Qualification IEEE 323-1974 4574/d-1/s a
Facility: Fort Calhoun 1 Docket No.: 50-285 S-301 SYSTEM COMPONENT EVALUATION WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUISTANi)-
CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD IIT16 Pa rameter cation cation cation cation
~ System: Electrical Equipment Operating Time Continuous Continuous 2
1 Type Test NONE Item No.: N/A Tempera-Rm 21 & 22 ture *F 109*F 385*F 2
1 Type Test NONE Component: Splices Pressure PSIg N/A 66 PSIg N/A 1
Type Test NONE Manufacturer: Raychem Relative Rm 21 & 22
-Model No.: Raychem Breakout Humidity %
100%
100%
2 1
Type Test NONE kits Function: Splices for Inter-Chemical 7'
facing in all Systems Spray N/A N/A N/A 1
Type Test NONE 03 Accuracy - Spec: N/A 1
8 Demon: N/A Radiation Note 1 2.9x10 3
1 Type Test NONE Se rvice: All Systems Location: Balance of Aux Bldg Aging N/A N/A N/A N/A N/A N/A Flood Level Elev: N/A Submer-l Above Flood Level:
gence N/A N/A N/A N/A N/A N/A Documentation'
References:
Notes:
5
- 1) Environmental Qualification Test Report
- 1) Rm 69 2.5x10 R of Raychem WCSF-N Nuclear In-Line Cable Ras 21 & 22 - 7x10 R
(
6 8
Splice-Assemblies for Raychem Corporation 5/15/80 Rm 13
- 4x10 R 5
- 2) Combustion Engineering Study " Evaluation of Fort Calhoun Rm 60
- 6x10 R 5
Safety Injection Pump Room Temperature following a loss Rm 59
- 8x10 R of coolant accident" See OPPD letter to the NRC dated 9/6/79.
- 3) "Inapienentation Methods and Schedules for NUREG-0578" Section 2.1.6b, Pages 16-19 Figures 4.2-1, 4.2, 4.2.3 & 4.2.4-(December 1979)
Present Qualification IEFJ. 323-1974
I Fccility: Fort Calhoun 1 Dock t No.: 50-285 S-302 SYSTEM COMPONENT EVALUATION WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Electrical Equipment Operating j
Time Continuous Continuous 1
2 Type Test NONE Item No.: N/A Tempera-ture 'F 216*F 385 F 1
2 Type Test NONE Component: Splices Pressure PSIg 1.2 PSIg 66 PSIg 1
2 Type Test NONE Manufacturer: Raychem Relative Model No.: Raychem Breakout Humidity %
100%
100%
1 2
Type Test NONE l
kits Function: Splices for Inter-Chemical facing in all Systems Spray N/A N/A N/A N/A N/A NONE y,
. a, l g Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service:- All Systems Location: Room 81 Aging N/A N/A N/A N/A N/A NONE Flood Level Elev:
1037.4' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Reference Enclosure #2.
- 2) Environmental Qualification Test Report of Raychem WCSF-N Nuclear In-Line Cable Splice Assemblies for Raychem Corporation 5/15/80 Present Qualification IEEE 323-1974 4574/d-2/s
Fccility: Fort Calhoun 1 Dock t No.: 50-285 S-303 SYSTEM COMPONEhT EVALUATION WORK SHEET ENVIRONMEhT DOCUMENTATON REF.
QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Electrical Equipment Operating Time Continuous Continuous 1
3 Type Test NONE Item No.: N/A Tempe ra-Rm 21 & 22 ture *F 109 F 346 F 1
3 Type Test NONE Component: Cable Pressure PSIg N/A N/A N/A N/A N/A NONE Manufacturer: Rockbestos Relative Rm 21 & 22 Model No.: Fire Wall III Humidity %
100%
100%
1 3
Type Test NONE Function: Interconnecting -
Chemical T'
cables for all Systems Spray N/A N/A N/A N/A N/A NONE 05 Accuracy - Spec: N/A Demon: N/A Radiation Note 1 2x108 2
3 Type Test NONE Service: All Systems Location: Balance of Aux Bldg Aging N/A N/A N/A N/A N/A NONE Flood Level Elev: N/A Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
5
- 1) Combustion Engineering Study " Evaluation of Fort Calhoun
- 1) Rm 69
- 2.5x10 R 8
Safety Injection Pump Room Temperature following a Loss Rms 21 & 22 - 7x10 R 8
of Coolant Accident" See OPPD letter to the NRC dated Rm 13
- 4x10 R 9/6/79.
Rm 60
- 6x10sR 5
- 2) " Implementation Methods and Schedules for NUREG-0578" Section Rm 59
- 8x10 R 2.1,6b, Pages 16-19 Figures 4.2-1, 4.2-2, 4.2-3 & 4.2-4 (December 1979)
- 3) Qualification of Fire Wall III, Class IE Electric Cables 2/1/77 Present Qualification IEEE 323-1974
Fccility: Fort Calhoua 1 Dock 2t No.:
50-285 C-250 SYSTEM COMPONENT EVALUATION VORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Ppecifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter kation cation cation cation System: Electrical Equipment Operating Time Continuous Continuous 1
2 Type Test NONE Item No.: N/A Tempera-ture *F 305 F 346*F 1
2 Type Test NONE Component: Cables Pressure PSIg 60 PSIg 113 PSIg 1
2 Type Test NONE Manufacturer: Rockbestos Relative Model No.: Fire Wall III Humidity %
100%
100%
1 2
Type Test NONE Function: Interconnecting Chemical 1700 ppm 3000 ppm O'
Cables for all Systems Spray Boren Boron 1
2 Type Test NONE E'
Accuracy - Spec: N/A Worst Case 2x10 Rads 2x108 7
Demon: N/A Radiation 1
2 Type Test NONE Se rvice: All Systems Location: Room 81 Aging 40 yrs 40 yrs 1
2 Type Test NONE Flood Level Elev:
1000.9' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Enclosure #1.
- 2) Qualification of Fire Wall III Class IE Electric Cable 2/1/77 Present Qualification IEEE 323-1974 4574/d-4/s
Fccility: Fort Calbrun 1 Docket No.: 50-285 S-304 SYSTEM COMPONENT EVALUATION M)RK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIF7.-
OUTSTANI)-
CATION It'~
EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter ration cation cation cation System: Electrical Equipment Operating Time
- ontinuous Coctinuous 1
2 Type Test N0hI Item No.: N/A Tempera-ture F 216*F 346*F 1
2 Type Test NONE Component: Cables Pressure PSIg 1.2 PSIg 113 PSIg 1
2 Type Test NONE Manufacturer: Rockbestos Relative Model No.: Fire Wall III Humidity %
100%
100%
1 2
Type Test NONE Function: Interconnecting unemical y
Cables for all Systems Spray N/A N/A N/A N/A N/A N0hT g.
c7 Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service:.All Systems.
Location: Room 81 Aging N/A N/A N/A N/A N/A N0hT Flood Level Elev:
1037.4' Submer-Above Flood Level:
gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Enclosure #2.
- 2) Qualification of Fire Wall III Class IE Electric Cable 2/1/77 Present Qualification IEEE 323-1974 4574/d-6/s F
4
Fccility: Fort Calhoun 1 Docket No.:
50-285 C-200 SYSTEM COMPONFET EVALUATON KORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-MFTHOD ITEMS Parameter cation cation cation cation System: Radiation Monitoring Operating Time Note 1 Note 2 2
3 Type Test NONE Item No.: RM-091A RM-091B Tempera-ture *F 305 F 357 F 1
3 Type Test NONE Component: Detector Pressure PSIg 60 PSIg Note 2 1
3 Type Test NONE Manufacturer: Victoreen Relative Model No.: 878 Humidity %
100%
100%
1 3
Type Test NONE Function: High range containment Chemical Radiation Area Monitor Spray 1700 ppm 3000 ppm 1
3 Type Test NONE i
E; Accuracy - Spec:
Note 3 6
7 j3 Demon:
Radiation 1x10 R 1x10 R 1
3 Type Test NONE Service:
Location: Containment Aging N/A 40 yrs N/A 3
Type Test NONE Flood Level Elev:
1001.0' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) IE Bulletin 79-01B submittal Enclosure #1.
- 1) During and continuously after DBA.
- 2) NUREG 0737
- 2) 1 year under accident environment.
7,
- 3) Qualification Type Test Data Report for
- 3) See Enclosure 13 item 16.
Class IE Victoreen High Range Containment u,
?3 Radiation Area Monitor System
. R3 Present Qualification IEEE 323-1974 4574/b-9/s
Fccility: Fort Calhoun 1 Docket No..
50-285 S-6 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OITISTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Note 1 1000 hrs Note 1 2
Type Test NONE Item Nc.: HCV-1101u & 1108B Tempera-ture F 216 F 346 F 1
2 Type Test NONE Component: Solenoid Valve #1 Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP 8320A175E Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical St/ Gen RC-2A & RC-2B Aux FW Spray N/A N/A N/A N/A N/A NONE 7'
inlet valves Accuracy - Spec: N/A u)
Demon: N/A Radiation N/A N/t.
N/A N/A N/A NONE Service: Isolation of Aux FW Lines Location: Room 81 Aging N/A 10 yrs N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE-Documentation
References:
Notes:
- 1) See Enclosure #2.
- 1) Valves are locked open and do not operate during an
- 2) ASCO Test Report Model AQS 21678/TR event.
Ed Present Qualification g;
IEEE 323-1974 I3 m
4574/b-6/s
Fccility: Fort C:1houn 1 Docket No.:
50-285 S-7 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMEhT DOCUMEhTATON REF.
QUALIFI-OLTISTAND-CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rame ter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Note 1 1000 hrs Note 1 2
Type Test NONE Item No.: HCV-1107B & 1108B Tempera-ture F 216 F 346 F 1
2 Type Test NONE Component: Solenoid Valve #2 Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP 8314C29E Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical St/ Gen RC-2A & RC-2B Aux FW Spray N/A N/A N/A N/A N/A NONE T'
inlet valves g;
j Accuracy - Spec:
N/A c)
Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation of Aux FW Lines Location: Room 81 Aging N/A 10 yrs N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) See Enclosure #2.
- 1) Valves are locked open and do not operate during an
- 2) ASCO Test Report Model AQS 21678/TR event.
Present Qualification n3 22 IEEE 323-1974 2
l R$
4574/b-5/s
Fccility: Fort Calhoun 1 Dockst No.:
50-285 S-201 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND.
CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator,.
Operating Feedwater & Blowdown Time Intermitter t 1000 hrs.
1 l 2 Type Test NONE Item No.: FCV-1368, 1369 Tempera-ture F 216 F 346 F 1
2 Type Test N0hI Component: Solenoid Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP8314C29E Humidity %
100%
100%
1 2
Type Test NONE Functica: Valve Actuators for Chemical Aux. Feedwater Valves Spray N/A N/A N/A N/A N/A NONE T
G Accuracy - Spec: N/A Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation of Aux.
Feedwater Line Location: Room 81 Aging N/A 10 yrs.
N/A 2
T3Te Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE t
Documentation
References:
Notes:
- 1) Enclosure #2.
- 2) ASCO Test Report Model AQS 21678/TR
.R Present Qualification IEEE 323-1974 1N 4574/b-7/s
[
1
'Fecility:. Fort Calhoun'1 Docket No.: 50-285 S-200 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTMD<
CATION ING
-EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter cation cation cation cation
)
System: Steam Generator, Operating Feedwater & Blowdown Time Intermitte it 1000 hrs.
I 2
Type Test NONE Item No.: FCV-1368, 1369 Tempera-ture *F 216 F 346*F 1
2 Type Test NONE
\\
Component: Solenoid Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP8314C29E Humidity %
100%
100%
1 2
Type Test NONE Function:' Valve Actuators for Chemical Aux..Feedwater Valves Spray N/A N/A N/A N/A N/A NONE os.
g3 Accuracy - Spec: N/A
@j Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation & Control of Aux. Feedwater Lines Location: Room'81 Aging N/A 10 yrs.
N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes gence N/A N/A N/A N/A N/A NONE Documentation
References:
Notes:
- 1) Enclosure #2.
- 2) ASCO Test Report Model AQS 21678/TR Present Qualification fw IEEE 323-1974 A4
-l$
4574/b-4/s
~
1
Fecility: Fort Celhoun 1 Docket No.:
50-285 S-202 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTANDi CATION ING EQUIPMENT DF.SCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Inte rmitte it 1000 hrs.
1 2
Type Test NONE Item No.: YCV-1045 Tempera-ture F 216*F 346 F 1
2 Type Test NONE 4~
Component: Solenoid Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE f'
Manufacturer: ASCO Relative Model No.: NP8314C29E Ilumidity %
100%
100%
1 2
Type Test NONE Function: Valve Actuators for Chemical Aux. Feedwater Valves Spray N/A N/A N/A N/A N/A NONE i
,j Accuracy - Spec:
N/A cq Demon: N/A Radiation N/A N/A N/A N/A N/A NCNE Se rvice : Isolation & Control of Aux. Feedwater Line
{
Location: Room 81 Aging N/A 10 yrs.
N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-Above Flood Level: Yes ge'nce N/A N/A N/A N/A N/A NONE f
Documentation
References:
Notes:
- 1) Enclosure #2.
- 2) ASCO Test Report Model AQS 21678/TR i,
Present Qualification IEEE 323-1974 4574/b-2/s
Facility: Fort Calhoun 1 Docket No.: 50-285 S-203 SYSTEM COMPONENT EVALUATON WRK SHEET t
ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTAND <
CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Pa rameter cation cation cation
' cation System: Steam Generator, Operating Feedwater & Blowdown Time Intermitteat 1000 hrs.
1 2
Type Test NONE Item No.: YCV-1045A, 1045B Tempera-ture F 216 F 346 F 1
2 Type Test NONE Component: Solenoid Pressure PSIg 1.2 PSIg 110 PSIg 1
2 Type Test NONE Manufacturer: ASCO Relative Model No.: NP8320A185V Humidity %
100%
100%
1 1
Type Test NONE Function: Valve Actuators for Chemical Aux. Feedwater Valves Spray N/A N/A N/A N/A N/A NONE i
g; Accuracy - Spec: N/A E3 Demon: N/A Radiation N/A N/A N/A N/A N/A NONE Service: Isolation & Control of Aux. Feedwater Line Location: Room 81 Aging N/A 10 yrs.
N/A 2
Type Test NONE Flood Level Elev:
1037.4' Submer-ge'ce N/A N/A N/A N/A N/A NONE Above Flood Level: Yes n
Documentation
References:
Notes:
- 1) Enclosure #2.
- 2) ASCO Test Report Model AQS 21678/TR Present Qualification IEEE 323-1974 4574/b-3/s o
Fecility: Fort Calhoun 1 Docket No.: 50-285 S-204 SYSTEM COMPONENT EVALUATON WORK SHEET ENVIRONMENT DOCUMENTATON REF.
QUALIFI-OUTSTANDa CATION ING EQUIPMENT DESCRIPTION Specifi-Qualif-Specifi-Qualifi-METHOD ITEMS Parameter cation cation cation cation System: Steam Generator, Operating Feedwater & Blowdown Time Continuous Continuou s 1
2 Type Test NONE Item No.: YCV-1045, YCV-1045A, YCV-1045B, FCV-1368, FCV-1369 Tempera-HCV-1107B, 1108B Solenoids #1&2 ture F 216 F 340*F 1
2 Type Test NONE Component: Limit Switch Pressure PSIg 1.2 PSIg 70 PSIg 1
2 Type Test NONE Manufacturer: NAMCO Relative Model No.: EA 180-11302 Humidity %
100%
100%
1 2
Type Test NONE Function: Valve Position Chemical PH 10-11 Indicators Spray N/A Boron 1
2 Type Test NONE il e
s' Accuracy - Spec: N/A 8
gj Demon: N/A Radiation N/A 2x4x10 R 1
2 Type Test NONE Service:
Location: Room 81 Aging N/A Note 2 Note 2 Note 2 Type Test NONE Flood Level Elev:
1037.4' Submer-Type Test
~
Above Flood Level: Yes gence Note 1 Note 1 N/A N/A Note 1 NONE Documentation
References:
Notes:
- 1) Enclosure #2.
- 1) The switches were sealed and tested to 70 PSIg. The District
- 2) NAMCO Test Report Model EA180 9/5/78 considers them capable of withstanding submergence.
7o
- 2) Switches qualified for 40 years using NAMCO recommended cg Present Qualification maintenance. NANCO letter dated 7/16/80.
?3 IEEE 323-1974-A l0 4574/b-1/s 4