MONTHYEARML17355A2312017-12-15015 December 2017 Areva, Inc. - Request for Review and Approval of ANP-10346P, Revision 0, ATWS-1 Analysis Methodology for BWRs Using RAMONAS-FA Project stage: Request ML18059A9542018-03-13013 March 2018 Acceptance Review Letter for Framatome Topical Report ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA Project stage: Acceptance Review ML18193A9862018-07-30030 July 2018 Transmittal of Regulatory Audit Plan for June 11-13, 2018, Audit for Topical Report ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA Project stage: Other ML18254A1352018-09-21021 September 2018 Request for Additional Information for ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA (Non-Proprietary) Project stage: RAI ML18228A8002018-09-21021 September 2018 Request for Additional Information Regarding Topical Report ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA Project stage: Request ML18228A8222018-09-21021 September 2018 Transmittal of Request for Additional Information Regarding Topical Report ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA Project stage: RAI ML18249A2252019-04-25025 April 2019 Audit Report for the June 11 - 13, 2018, Audits in Support of the Review of ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA Project stage: Request ML18249A2372019-04-25025 April 2019 Audit Report for the June 11 - 13, 2018, Audit in Support of the Review of ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA (Non-Proprietary Version) Project stage: Approval ML19078A0762019-04-25025 April 2019 Audit Report for the June 11 - 13, 2018, Audit in Support of the Review of ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA Project stage: Approval ML19276E4752019-10-30030 October 2019 Final Safety Evaluation for Framatome Inc. Topical Report ANP-10346, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA (Non-Prop Version) Project stage: Approval ML19276E5772019-10-30030 October 2019 Transmittal of Final Safety Evaluation for Framatome Inc. Topical Report ANP-10346, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA (Non-Proprietary Version) Project stage: Approval ML19276E4362019-10-30030 October 2019 Final Safety Evaluation for Framatome Inc. Topical Report ANP-10346, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA (Non-Proprietary Version) Project stage: Request ML20045C1902020-03-0202 March 2020 Verification Letter of the Approval Version of Framatome Inc. Topical Report ANP-10346P-A, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA Project stage: Other 2018-09-21
[Table View] |
Text
March 2, 2020 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome Inc.
3315 Old Forest Road Lynchburg, VA 24501
SUBJECT:
VERIFICATION LETTER OF THE APPROVAL VERSION OF FRAMATOME INC.
TOPICAL REPORT ANP-10346P-A, REVISION 0, ATWS-I ANALYSIS METHODOLOGY FOR BWRs USING RAMONA5-FA (EPID L-2017-TOP-0067)
Dear Mr. Peters:
By letter dated January 30, 2020 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML20034E886), Framatome Inc. (Framatome) submitted an approval
(-A) version of Topical Report (TR) ANP-10346P-A, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA, to the U.S. Nuclear Regulatory Commission (NRC) staff. Framatome has done so in accordance with our request to publish approval proprietary and non-proprietary versions of this TR, as detailed in the transmittal letter dated October 30, 2019, of the NRC staffs final safety evaluation (ADAMS Accession No. ML19276E577) for the original TR.
The NRC staff has completed its review of the approval version of the TR. The NRC staff verified that Framatome has met the requirements and determined that the submitted -A versions are acceptable for referencing in licensing applications for nuclear power plants to the extent specified and under the limitations delineated in the accepted versions of the TR. TR ANP-10346P-A, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA, is now approved for use in future licensing actions.
Please contact Jonathan G. Rowley of my staff at (301) 415-4053 if you have any questions on this subject.
Sincerely,
/RA/
Dennis C. Morey, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99902041
ML20044C190 *concurrence via e-mail OFFICE NRR/DORL/LLPB NRR/DORL/LLPB* NRR/DSS/SFNB NRR/DORL/LLPB NAME JRowley DHarrison RLukes DMorey DATE 02/14/2020 2/24/2020 02/25/2020 03/02/2020