Training Material for E-111 Emergency Diesel Generator Course, Appendix a - References (3-16)
ML20043F650
Person / Time
Issue date: 02/12/2020
From:
Office of the Chief Human Capital Officer, Woodard Corp
To:
Gary Callaway
Shared Package
ML20043F634 List:
References
Download: ML20043F650 (6)


Text

Emergency Diesel Generator Appendix A - References APPENDIX A - REFERENCES Part A USNRC Regulatory Documents 1 Criteria and Regulations

  • Atomic Energy Commission General Design Criteria Criteria 38, 39, 49
  • U. S. Code of Federal Regulations Table 10 - Energy Part 50 - Domestic Licensing of Production Facilities Sections 10, 22, 23, 24, 36, 54, 55, 56, 57, 63, Appendix A & B Regulatory Guides 1.108 - Periodic Testing of Diesel Generator Units Used as Onsite Electric Power Systems at Nuclear Power Plants 1.118 - Periodic Testing of Electric Power and Power Protection Systems 1.137 - Fuel-Oil Systems for Standby Diesel Generators 1.155 - Station Blackout 1.160 - Monitoring the Effectiveness of Maintenance at Nuclear Power Plants 1.29 - Seismic Design Classification 1.32 - Criteria for Safety Related Electric Power Systems for Nuclear Power Plants 1.6 - Independence Between Redundant Standby (Onsite) Power Sources 1.75 - Physical Independence of Electric Systems 1.89 - Environment Qualifications of Certain Electric Equipment to Safety for Nuclear Power Plants 1.9 - Selection, Design, Qualification, and Testing of Emergency Diesel Generator Units 1.93 - Availability of Electric Power Sources Part B Categorical References and Case Histories
1. Diesel Engine - Mechanical Failures and Design Issues
  • 10CFR21-0095 Report, 2008-10-21 Defective Ingersol-Rand Series 89 Air Start Motors

Rev 3/16 1 USNRC HRTD

Emergency Diesel Generator Appendix A - References

  • 10CFR21 Report, 2007-04-09 FM OP Diesel Engine Cam Roller Bushing Failures (Incorrect Material Hardness)
  • 10CFR21 Reports, 2006-12-22 and 2007-01-08 New Woodward Governor Digital Reference Unit (DRU) Setup to Address Unevaluated Failure Mode
  • 10CFR21 Report, 2006-06-13 Defective Nordberg EDG Valve Seat Inserts (Improper Size Inserts May Drop from Head into Cylinder)
  • 10CFR21 Report, 2005-09-16 Falling Isoprene EDG Governor Drive Couplings on Transamerica DeLaval EDGs at 6 Nuclear Power Plants
2. Emergency Diesel Generator - Electrical and Controls Related Failures
  • 10CFR21 Report, 2006-12-16 EDG MCC Circuit Breaker Design Set Point Low (Loss of Cooling Fans, etc, for SACM EDG)

Rev 3/16 2 USNRC HRTD

Emergency Diesel Generator Appendix A - References

  • 10CFR21 Report, 2005-04-12 Defective Woodward Governor Compensating-Type EG Series Actuators (Null Voltage Shift)
  • 10CFR21 Report, 2004-04-23 and 2006-01-23 Defective IC Chips in Some Woodward Governor DRUs May Result in Erratic Speed Control
3. Emergency Diesel Generator Failures Resulting from Maintenance/ Painting/

Cleaning/ Miscellaneous

4. Site Switchyard, Electrical Distribution Issues (Including Aging)
5. Fires and Fire Protection Issues Potentially Affecting Emergency Systems

Emergency Diesel Generator Appendix A - References

6. Grid Reliability and Potential Impact on Nuclear Power Plants
  • Generic Letter 2006-02 Grid Reliability, Risk Assessment, NPP-TSO Communications, Maintenance Schedule Considerations
7. Fuel Oil and Lubricating Oil Issues

Emergency Diesel Generator Appendix A - References PART C U.S. Nuclear Regulation Commission Publications

1. Regulatory Guide 1.9, Rev. March 2007.
2. A Reliability Program for Emergency Diesel Generators at Nuclear Power Plants, NUREG/CR-5078, Vol. 2, Prepared by Science Applications International Corporation and Sandia National Laboratories, Pub. By USNRC.
3. NRC Inspection Manual, Part 9900, Technical Guidance Degraded Conditions, Operability, et.al; NUREG 0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants.
4. Performance of Emergency Diesel Generators in Restoring Power to Their Associated Safety Busses - A Review of Events Occurring at Power Plants, AEOD-591-01.
5. NRC Inspection Manual, Inspection Procedure 71707, Operational Safety Verification.
6. NRC Inspection Manual, Inspection Procedure 17710, Engineered Safety Feature Walkdown.
7. NRC Inspection Manual, Inspection Procedure 62703, Monthly Maintenance Observation.
8. NRC Inspection Manual, Inspection Procedure 61726, Surveillance Observation.
9. NRC Inspection Manual, Inspection Procedure 2515/93, Inspection for Verification of Quality Assurance Requests Regarding Diesel Generator Fuel Oil Multi-plant Action Item A-15.
10. Operating History Overview for Diesel Generators in Nuclear Service, USNRC Report AEOD/P401, February, 1984 PART D Commercial Codes, Standards, and Publications
1. IEEE Standard Criteria for Diesel Generator Units Applies as Standby Power Supplies for Nuclear Power Generating Stations, IEEE Standard 387-1995, Pub. By The Institute of Electrical Engineers, Inc., New York, NY 10017
2. IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations, IEEE Standard 323-1983. Pub. By The Institute of Electrical Engineers, Inc.,

New York, NY 10017.

3. Standard Fuel Specifications for Diesel Fuel Oils, ASTM Designation D 975-93, Pub. By American Society for Testing and Materials, Philadelphia, PA 19103.

Rev 3/16 5 USNRC HRTD

Emergency Diesel Generator Appendix A - References

4. Standard Test Method for Sulfur in Petroleum Products (High Temperature Method),

ASTM Designation D 1552-930 Pub. By American Society for Testing and Materials, Philadelphia, PA 19103.

Commercial codes / standards are available on the appropriate IEEE, ASTM, etc. web sites.

Part E Books and Manuals

1. Diesel Engineering Handbook, Karl W. Stinson, M.E.; Pub. by Business Journals Inc.,

Norwalk, CT 06855; 1980.

2. Fundamentals of Diesel Engines - U.S. Navy, NAVPERS; Pub. by Standards of Curriculum, Division Training, Bureau of Naval Personnel; 1951.
3. Diesel and High Compression Gas Engines, E. J. Kates and W. E. Luck, Pub. by American Technical Publishers, Inc., Alsip, IL 60658; 1974.
4. Principles of Energy Conversion, Archie W. Culp, Jr.; Pub. by McGraw-Hill Book Company; 1979.
5. Electric MACHINERY - The Dynamics and Statics of Electromechanical Energy Conversion, A. E. Fitzgerald and Charles Kingsley; Pub. by McGraw-Hill Book Company.
6. Standard Test Method for Particulate Contaminates in Aviation Fuel by Line Sampling, ASTM Designation D 2276-93; Pub by American Society for Testing and Materials, Philadelphia, PA 19103.
7. Standard Practice for Manual Sampling of Petroleum and Petroleum Products; ASTM Designation D 4057-88; Published by American Society for Testing and Materials, Philadelphia, PA 19103.
8. Standard Test Method for Free Water and Particulate Contamination in Distillate Fuels (Visual Inspection Procedures); ASTM Designation D 4176-93; Published by American Society for Testing and Materials, Philadelphia, PA 19103.
9. Guidelines for the Utilization of Commercial Grade Items in Nuclear Safety Related Applications (NCIG-07) EPRI Report NP-5652, Final Report, June 1988; Pub by Electric Power Research Institute, Palo Alto, CA 94304.
10. Diagnostic System Summary, Predictive Maintenance-Condition Monitoring Integration; Pub. by Electric Power Research, Eddystone, PA.
11. Woodward Controls for Generator Sets; Woodward Governor Company, Fort Collins, Co 80522; 1985.

Rev 3/16 6 USNRC HRTD