ML20041D020

From kanterella
Jump to navigation Jump to search

Notifies That plant-specific Ref to GE 810506 & 28 Position Is Acceptable Basis for Request to Extend Burnup for All Fuel Types.Limits Inherent in 10CFR51.20 Re Environ Effects from Transport of Irradiated Fuel Should Not Be Neglected
ML20041D020
Person / Time
Site: Hatch  
Issue date: 02/03/1982
From: Stolz J
Office of Nuclear Reactor Regulation
To: Beckham J
GEORGIA POWER CO.
References
TAC-51054, TAC-52448, NUDOCS 8203040072
Download: ML20041D020 (2)


Text

.

FEBRUARY (i $ 282 V(?

J DISTRIBUTION:

L PDR AE0D Docket File TERA IE-3 flRC PDR NSIC ACRS-10 Dockets Hos. 50-321 ORB #4 Rdg Gray File-2 LDsD in a

and 50-366 DEisenhut

't MFairtile im RIr. gram C

'C

}

y OELD C

@Bg IOS23

!!r. J. T. Beckhan, Jr.

[

Vice President - Engineering g7y,&

Georgia Power Company A

P. O. Box 4545 N

NiTTg' Atlanta, Georgia 30302

Dear Mr. Beckham:

The General Electric Company (GE) requested (Refs.1-2) that credit for approved, but unapplied ECCS evaluation model changes be used to i

offset MAPLHGR penalties on operating reactors due to high burnup fission gas release. Should you fin 6 the positions stated in those letters applicable to the llatch Nuclear Plant Units 1 and 2, and wish to apply the GE proposal to offset potential, or previously applied, ifAPLilGR penalties, we would find a plant-specific reference to the GE position an acceptable basis for a request to extend burnup for all fuel types. Itowever, do not neglect the linits on burnup inherent in 10 CFR Dart 51.20g(2)(iii) regarding the environnental effects from the transportation of irradiated fuel.

1.

R. E. Engel (GE) to T. A. Ippolito (fiRC) on " Extension of ECCS Performance Limits" dated May 6,1931.

2.

R. E. Engel (GE) to _T. A. Ippolito (llRC) on " Extension of ECCS Performance Limits" dated !!ay 28, 1981.

S Sincerely, aoaIGI:U.L 3:aa ar J0r n. m L4" John F. Stolz, Chief Operating Reactors Dranch #4 Division of Licensing cc:

See next page B203040072 820203 PDR ADOCK 05000321 f

P PDR

$ 1 mJ

" ORB #dDI

C f #4?OL o,nc,, lWsTRTTE~&"JE :""""'" ;""'"""""'""

" " " ~ " ' " " " " '

suRme >

2

..../../. 82 2

..../...l../.82 onre >

NRC FORM 318 0o-80) NRCM ovo OFFiClAL RECORD COPY usc : mi-m.co

~

Hatch 1/2 G:orgia Power Company 50-321/366 ccw/ enclosure (s):

Mr. James P. O'Reilly, Regional Administrator ha,

ots$ndTrowbridge R io I

II*

,,ho'rga b3 i g on 20036 3

Ruble A. Thomas Vice President P. O. Box 2625 Southern Services, Inc.

Birmingham, Alabama 35202 Ozen Batum Charles H. Badger P. O. Box 2625 Office of Planning and Budget Southern Services, Inc.

Room 610 Birmingham, Alabama 35202 270 Washington Street, S.W.

Atlanta, Georgia 30334 Appling County Commissioners County Courthouse Baxley, Georgia 31513 Mr. L. T. Gucwa Georgia Power Company

- Engineering Department P. O. Box 4545 Atlanta, Georgia 30302

.Mr. Max.Manry Georgia Power Company Edwin I. Hatch Plant P. O. Box 442 Baxley, Georgia 31513 a

Regional Radiation Representative EPA Region IV 345 Courtland Street, N.E.

Atlanta, Georgia 30308 Appling County Public Library 301 City Hall Drive Baxley, Georgia 31513 Mr. R. F. Rodgers.,

U.S. Nuclear Reaulatory Conmission Route 1, P. O. Box 279 Baxley, Georgia 31513

.