Notice of Violation from Insp on 810826-0925
ML20039A004
Person / Time
Site: Catawba  
Issue date: 10/26/1981
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20038D148 List:
References
50-413-81-22, 50-414-81-22, NUDOCS 8112160127
Download: ML20039A004 (2)


Text

.

L.

APPENDIX A 1

NOTICE OF VIOLATION Duke Power Company Docket Nos. 50-413 h 50-414 Catawba 1 and 2 License Nos. CPPR-116 & CPPR-117 As a result of the inspection conducted on August 26 - September 25, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7,1980),

the following violations were identified:

A.

10 CFR 50, Appendix B, Criterion V, as implemented by Topical Report Duke i

1-A, Section 17, paragraph 17.1.5 requires that instructions include appropriate quantitative acceptance criteria for detenaining that important activities have been satisfactorily accomplished.

Contrary to the above,' instructions did not contain appropriate quantitative-acceptance criteria on June 9,1981, in that the specification for installation of electrical power cables, Specification No. 1390.01-00-0022, did not clearly delineate requirements for separation between adjacent power cables.

This resulted in numerous power cables being installed in contact for a greater length than that which was later determined to be acceptable.

This is a Severity Level VI Violation (Supplement II.F.).

-B.

10 CFR 50, Appendix B, Criterion V, as implemented by Topical Report Duke 1-A, Section 17, paragraph 17.1.5 requires that instructions include appropriate qualitative acceptance criteria for determining that important activities have been satisfactorily accomplished.

The applicable code for Class B safety-related piping; ASHE,Section III, paragraph NC-2539.4; requires liquid penetrant inspection of base metal weld repairs.

Contrary to the above, instructions did not contain appropriate qualitative acceptance criteria on September 18, 1981, in that instructions provided on Nonconformir.g Item Report No.12454 for weld repair of piping adjacent to i

Class B weld no.1FW22-6 did not require liquid penetrant inspection of the weld repair.

1 This is a Severity Level VI Violation (Supplement II.F.) applicable to Unit 1 only.

C.

10 CFR 50, Appendix B, Criterion V, as inplemented by Topical Report Duke 1-A, Section 17, paragraph 17.1.5 requires that activities affecting quality be accomplished in accordance with established procedures.

Licensee ~

procedure CP-479, Rev. 4 prohibits masking tape from being applied to the surface of safety-related stainless steel piping.

Contrary to the above, activities were not accomplished in accordance with established procedures on September 17, 1981 in that Shufords Shurtape General Purpose Crepe Paper Tape (A brand of masking tape) was applied to

'8112160127 811200

~

PDR ADOCK 05000413 G-PDR

a Duke Power Company 2

Docket Nos. 50-413 & 50-414 Notice of Violation License Nos. CPPR-116 & 117 masking tape) was applied to stainless steel piping associated with Class B weld Nos. 1BB52-13 and IBB52-14.

This is a Severity Level VI Violation (Supplement II.F.) applicable to Unit 1 only.

Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit to this office within thirty days of the date of this flotice, a written statement or explanation in reply, including:

(1) admission or denial of the alleged viola-tions; (2) the reasons for the violations if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved. Consideration may be given to extending your response time for good cause shown. Under the authority of Section 182 of the Atomic Energy Act of 1954, as amended, this response shall be submitted under oath or affirmation.

The responses directed by this flotice are not subject to the clearance procedures of the Office of flanagement and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

Date: OCT 2 61981