ML20035H692

From kanterella
Jump to navigation Jump to search
Addendum to Radioactive Effluent Rept for Second Half, 1991, Consisting of Listing of Liquid Effluents
ML20035H692
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 12/31/1991
From:
COMMONWEALTH EDISON CO.
To:
Shared Package
ML20035H690 List:
References
NUDOCS 9305060232
Download: ML20035H692 (2)


Text

i QCP 100-S25 i

Revision 5 l

2ND HALF - 1991 LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES i

Quarter Quarter Est. Total Unit Third Fourth Error. %

A.

FISSION & ACTIVATION PRODUCTS j

1.

Total release (not including i

tritium gases, alpha)

Ci ** 2.56E-03 9.67E-03 7.2 2.

Average diluted concentration during batch dischargest period uCi/ml 1.94E-09 5.35E-09 9.1/E-UJ J./4E-UZ 3.

Percent of applicable limit

  • 3.70E-03 1.69E-02 4.

Maximum diluted concentration durina batch discharces uC1/mi 1.94E-09 5.35E-09

    • Note:

Al, A3 and B1 for both quarters include activity B.

TRITIUM from U-l RHR Hx leak. All other values are for normal batch release.

1.

Total release C1 ** 2.20E-01 4.04E-01 6.1 2.

Average diluted concentration during batch discharaes uC1/ml 2.16E-07 7.50E-07 3.

Percent of applicable limit 1

7.19E-03 2.50E-02 C.

DISSOLVED AND ENTRAINED GASES 1.

Total release C1

<LLD

<LLD N/A 2.

Average diluted concentration durina batch discharces uC1/ml

<LLD

<LLD 3.

Percent of applicable limit 0

0 D.

GROSS ALPHA RADIOACTIVITY 1.

Total Release Ci

<LLD

<LLD N/A 2.

Average concentration released during batch discharges uC1/mj

<LLD

<LLD E.

VOLUME OF WASTE RELEASED (prior 1.28E+05 1.33E+05 to dilution Liters F.

VOLUME OF DILUTION HATER USED 1.02E+09 5.05E+08 DURING BATCH DISCHARGES Liters G.

TOTAL VOLUME OF DILUTION 4.90E+11 6.70E+11 APPROVED WATER DURING PERIOD (OVARTER)

Liters

  • HHOLE BODY /0RGAN 9/0295c JUN 121989 9305060232 930427 PDR ADOCK 05000254 C'.C.O.S.R.

PDR R

QCP 100-525 Revision 5 LIQUID EFFLUENTS Continuous Mode Batch Mode Quarter Quarter Quarter Quarter Nuclides Released Unit Third Fourth Third Fourth Sr-89 C1

<LLD

<LLD 2.20E-05 1.38E-04 Sr-90 C1

<LLD

<LLD 2.47E-06 1.09E-05 Cs-134 C1

<LLD

<LLD 1.llE-05

<LLD i

Cs-137 Cj

<LLD

<LLD 1.69E-04 7.72E-04 I-131 Cj

<LLD

<LLD

<LLD

<LLD Co-58 C1

<LLD

<LLD 2.43E-05 3.08E-04 Co-60 C1

<LLD

<LLD 2.00E-03 6.92E-03 Fe-59 C1

<LLD

<LLD

<LLD

<LLD Zn-65 C1

<LLD

<LLD 6.01E-05 3.65E-05 i

<LLD

<LLD 1.06E-04 7.58E-04 Mn-54 C1

<LLD (LLD

<LLD 1.87E-04 Cr-51 C1

< LI.D

< 1,1.D

<1.1.D

<uD Zr-95 C1 (I.I.D

< 1.1.D (I,1.D

< 1.1.D Nb-95 C1

<I'1.D

<1.1.D (1,1,D

<LI.D Mo-99 C1

<1'I'D

<I I.D

<1.1.D

<1.1.D i

Aa-110m C1

<uD

< 1.1.D

< 1.1.D

<1.1.D Ba-104 C1 1.1.D

<1.1 D

<1,1.D Cs-136 C1 D

MD MD

<un La-140 C1

<LLD

<LLD 1.70E-04 4.78E-04 Fe-55 Cl Ubi&htifA46' Na-24 C1 (LLD (LLD

<LLD 6.26E-05 1

Total for Period (above)

C1

<uD

<LLD 2.56E-03 9.67E-03 j

Xe-133 C1

<tLD (uD

<uD

<uD Xe-135

_C1

<LLD

<LLD (LLD

<LLD Prepared by h

e Approved by ad d b o y

. Chem.1stry Supervisor-(final)

APPROVED 9/0295c.JUN 121989 N

-