t 1

i t

Rev. 11 04/08/93 I

]

4/!/6/98 I

Effective Date-i p m - msmr~.

- w--+eT = *:mam 9

[

oxuns:u sc.cuan a

g 3:

N E: 0 R M A T t G N O l4 L C. R. Wclear i

f smanaanver,6 i

ANNUNCIATOR RESPONSE l

AR-504 i

l l

l FLORIDA POWER. CORPORATION l

l i

CRYSTAL RIVER UNIT 3 i

l l

ICS L ANNUNCIATOR RESPONSE l

l l

1 THIS PROCEDURE ADDRESSES SAFETY RELATED COMPONENTS APPROVED BY:

Interpretation Contact

  1. .!/V,,b3 DATE:

s INTERPRETATION CONTACT: Manager, Nuclear Plant Operations-9304220061 930414

-PDR ADOCK 05000302 P

PDR

. - * =, - - - -

eg y

w...

.w..t.

w-

I i

1 O

aev. >>

04 08eeS Effective Date-4/

6/98

~!

t e

pm smaerana-._ _. -.an-mecma=rumq Document Section q

g N F O R M A T I O N O N L h,,

[

l I

I C. R. Noc' ear

]

v

~

_gamgmw _

--~~~m I

ANNUNCIATOR RESPONSE AR-504 FLORIDA POWER' CORPORATION CRYSTAL RIVER UNIT 3 l

f l

ICS L ANNUNCIATOR RESPONSE i

i THIS PROCEDURE ADDRESSES SAFETY RELATED COMPONENTS.

l l

APPROVED BY:

Interpretation Contact-

//./N.[C3 DATE:

f INTERPRETATION CONTACT: Manager, Nuclear Plant Operations 9304220061 930414

^

PDR ADOCK 05000302 P

PDR

)

1 TABLE OF CONTENTS O

1 SECTION PAGE i

i 1.0 PURPOSE.............................

1 t

I

2.0 REFERENCES

2.1 INPLENENTING REFERENCES..............

1 2.2 DEVELOPNENTAL REFERENCES I

r i

3.0 PERSONNEL INDOCTRINATION 1

i 4.0 INSTRUCTIONS 1

5.0 FOLLOW-UP ACTIONS......................

1 i

t ENCLOSURES I

1 Annunciator Response.......................

2 i

t I

6 I

i t

i i

l l

l 1

l-l l

l

-AR-504-Rev. 11 Page i 1

i

,?

i i

1.0 ~

PURPOSE I

1.1 Establish a reference document for each Annunciator Window on the t

ICS-CY4 Lampbox.

l 1.2 Establish operator actions for valid Annunciator alarms on the ICS-

.l CY4 Lampbox.

1.3 Establish a reference to other procedures which address operator actions for valid Annunciator alarms on the ICS-CY4 Lampbox.

2.0 REFERENCES

j i

2.1 INPLENENTING REFERENCES 2.1.1 AP-545, " Plant Runback" 2.1.2 OP-605, "Feedwater System" 2.1.3 AP-450, " Emergency Feedwater Actuation" 2.2 DEVELOPNENTAL REFERENCES i

2.2.1 INP0 90-021, Good Practice OP-217, Alarm Response Procedures 2.2.2 Annunciator Window Engraving Drawing E-224-048 I

3.0 PERSONNEL INDOCTRINATION j

3.1 The Annunciator System is powered from VBDB-5 Breaker 28.

4.0 INSTRUCTIONS j

4.1 Respond to alarms on the ICS-CY4 Lampbox as indicated in Enclosure 1, Annunciator Response.

i 5.0 FOLLOW-UP ACTIONS None O

AR-504 Rev. 11 Page 1

I ENCLOSURE 1 O

(Page 1 of 73) 5 ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-01 L-01-01

)

h---

FWP A I

TRIP R

II l

l EVENT POINT 1455 1

INDICATED CONDITION:

o FEEDWATER PUMP 2A CONTROL OIL PRESSURE <55 PSIG AS SENSED BY FW-135-PS2.

l 1

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o CONTROL OIL PRESSURE INDICATION.

o RED TRIP INDICATING LIGHT IS ON.

o FEEDWATER PUMP SPEED INDICATOR.

OPERATOR ACTIONS FOR A VALID ALARM:

4 o IF REACTOR POWER >55% RTP, THEN REFER TO AP-545.

o IF ALL FEEDWATER HAS BEEN LOST, REFER TO AP-450.

l o VERIFY PROPER OPERATION OF_FEEDWATER BEARING / CONTROL OIL SYSTEMS.

DISCUSSION:

CONDITIONS THAT WILL TRIP A MAIN FEEDWATER PUMP:

TURBINE OVERSPEED (5,555 RPM)

_ LOSS OF TRIPPING POWER LOSS OF BOTH B0OSTER PUMPS LUBE OIL PRESS. <5 PSIG.

MISSING SPEED SIGNAL <100 RPM MAIN FEEDWATER ISO ACTUATION L

FEED PUMP SUCT. VALVES <25% OPEN MANUAL TURBINE TRIP.

REFERENCES:

DRAWING 20B-032 SHEET FW-45 SENSING ELEMENT:

FW-135-PS2 AR-504 Rev. 11 Page 2

I l

r

!I C ENCLOSURE I

(

(Page 2 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-01 L-01-01 i

i FWP A l

. TRIP I

ll ll EVENT POINT 1492 INDICATED CONDITION:

I o FEEDWATER PUMP 2A CONTROL OIL PRESSURE <55 PSIG AS SENSED BY FW-320-PS, i

FW-321-PS, FW-322-PS OR FW-323-PS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

( '^\\

o RPS CHANNEL A,B,C, OR D FEED PUMP TRIP AU.( RELAY MFP "A" INDICATION

(,/

IS BRIGHT.

o RED TRIP INDICATING LIGHT IS ON.

l o FEEDWATER PUMP SPEED INDICATOR.

OPERATOR ACTIONS FOR A VALID ALARM:

o IF REACTOR POWER >55% RTP, THEN REFER TO AP-545.

o IF ALL FEEDWATER HAS BEEN LOST, REFER TO AP-450.

i o VERIFY PROPER OPERATION OF FEEDWATER BEARING / CONTROL OIL SYSTEMS.

DISCUSSION:

THIS ALARM INDICATES THAT ONE OR MORE RPS CHANNELS HAS RECEIVED A FEED PUMP TRIP SIGNAL FROM THE CONTROL OIL PRESSURE SWITCHES ASSOCIATED WITH THAT FEED PUMP. THIS MAY NOT BE INDICATIVE OF AN ACTUAL FEED PUMP TRIP' CONDITION.

REFERENCES:

DRAWING 208-o32 SHEET FW-45 SENSING ELEMENT:

FW-320,321,322,3.23-PS AR-504 Rev. Il Page 3

ENCLOSURE I O

(Page 3 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-02 L-01-02 FWP A VIBRATION HIGH i

EVENT POINT 1464 INDICATED CONDITION:

o MAIN FEEDWATER PUMP 2A OUTBOARD PUMP BEARING VIBRATION IS EITHER:

>3.5 MILS, (ALERT) OR, >4 MILS, (DANGER) AS SENSED BY FW-269-MIS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATIONS.

o VIBRATION IS FELT AT FWP-2A.

l OPERATOR ACTIONS FOR A VALID ALARM:

i l

o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR 4

FURTHER PUMP OPERATION.

o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO REDUCING FLOW THROUGH THE PUMP UNTIL THE DANGER ALARM CAN BE CLEARED.

DISCUSSION:

REFER TO OP-605 FOR VIBRATION SETPOINTS.

THIS ALARM MUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

l

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-269-MIS

' O AR-504 Rev. II Page 4 r

l 1

O ENCLOSURE I (Page 4 of 73) l ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-02 L-01-02 FWP A VIBRATION HIGH EVENT POINT 1465 i

I i

l INDICATED CONDITION:

i o MAIN FEEDWATER PUMP 2A INBOARD TURBINE BEARING VIBRATION IS EITHER:

>2.4 MILS, (ALERT) OR, >3.5 MILS, (DANGER) AS SENSED BY FW-239-MIS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATIONS.

o VIBRATION IS FELT AT FWP-2A.

OPERATOR ACTIONS FOR A VALID ALARM:

o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR l

FURTHER PUMP OPERATION.

l o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO l

REDUCING FLOW THROUGH THE PUMP UNTIL THE DANGER ALARM CAN BE CLEARED.

i DISCUSSION:

l REFER TO OP-605 FOR VIBRATION SETPOINTS.

f THIS ALARM MUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

f i

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-239-MIS

~

AR-504 Rev. II Page 5 i

i ENCLOSURE 1 O

t (Page 5 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-02 L-01-02 i

FWP A l

VIBRATION HIGH l

l EVENT POINT 1466 l

INDICATED CONDITION:

o MAIN FEEDWATER PUMP 2A OUTBOARD TURBINE BEARING VIBRATION IS EITHER:

>2.4 MILS, (ALERT) OR, >3.5 MILS, (DANGER) AS SENSED BY FW-241-MISI.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l.

o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATI0:lS.

o VIBRATION IS FELT AT FWP-2A.

(

OPERATOR ACTIONS FOR A VALID ALARM:

l o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR i

FURTHER PUMP OPERATION.

i o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO REDUCING FLOW THROUGH THE PUMP UNTIL THE DANGER ALARM CAN BE CLEARED.

l i

DISCUSSION:

REFER TO OP-605 FOR VIBRATION SETPOINTS.

I THIS ALARM PUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT: FW-241-MIS 1 O

AR-504 Rev. 11 Page 6

"+1 e

i

~

ENCLOSURE I k

(Page 6 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-02 L-01-02

'l FWP A VIBRATION HIGH i

EVENT POINT 1469 INDICATED CONDITION:

o MAIN FEEDWATER PUMP 2A INBOARD PUMP BEARING VIBRATION IS EITHER:

>3.5 MILS, (ALERT) OR, >4.0 MILS, (DANGER) AS SENSED BY FW-267-MIS.

l REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATIONS.

o VIBRATION IS FELT AT FWP-2A.

OPERATOR ACTIONS FOR A VALID ALARM:

o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER PUMP OPERATION.

o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO REDUCING FLOW THROUGH THE PUMP UNTIL THE DANGER ALARM CAN BE CLEARED.

l DISCUSSION:

REFER TO OP-605 FOR VIBRATION SETPOINTS.

THIS ALAkM MUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION i

MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

I 1

REFERFNCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-267-MIS l

AR-504 Rev. II Page '7 l

l l

ENCLOSURE 1 O

(Page 7 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-03 L-01-03 i

FWP A OIL PRESS i

LOW f

EVENT POINT 1436 I

i INDICATED CONDITION:

i o FEEDWATER PUMP 2A LUBE OIL PRESSURE <18 PSIG AS SENSED BY FW-186-PS.

i i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

()

o FEEDWATER PUMP 2A LUBE OIL PRESSURE INDICATOR FW-203-PI.

o STANDBY LUBE OIL PUMP AUTO STARTS, FWP-3A, FWP-4A.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE STANDBY LUBE OIL PUMP AUTO STARTS.

o ENSURE PROPER FEED PUMP LUBE OIL RESERV0IR LEVEL.

l 0 ENSURE PROPER FEED PUMP LUBE OIL TEMPERATURE.

i l

DISCUSSION:

l l

FEED PUMP TRIPS AT LUBE OIL PRESSURE <5 PSIG.

l l

l i

REFERENCES:

DRAWING 208-032 SHEET FW-07 SENSING ELEMENT: FW-186-PS O-b l

AR-504 Rev. 11 Page 8

i i

l ENCLOSURE 1 (Page 8 of 73) l ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-03 L-01-03 l

FWP A i

OIL PRESS LOW l

f EVENT POINT 1437 INDICATED CONDITION:

l o FEEDWATER PUMP 2A CONTROL OIL PRESSURE <90 PSIG AS SENSED BY FW-195-PS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEEDWATER PUMP 2A CONTROL OIL PRESSURE INDICATOR FW-205-PI.

o STANDBY LUBE-0IL. PUMP AUTO STARTS, FWP-3A, FWP-4A.

4 OPERATOR ACTIONS FOR A VALID ALARM:

I o ENSURE STANDBY LUBE OIL PUMP AUTO STARTS.

i o ENSURE PROPER FEED PUMP LUBE OIL RESERV0IR LEVEL.

i o ENSURE PROPER FEED PUMP LUBE OIL TEMPERATURE.

DISCUSSION:

FEED PUMP CONTROL OIL SENDS A TRIP SIGNAL TO RPS WHEN CONTROL OIL PRESSURE IS <55 PSIG.

REFERENCES:

DRAWING 208-032 SHEET FW-07 SENSING ELEMENT:

FW-195-PS AR-504 Rev. 11 Page 9

t ENCLOSURE 1 O

(Page 9 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-03 L-01-03 i

I FWP A OIL PRESS LOW l

EVENT POINT 1448 INDICATED CONDITION:

o FEEDWATER PUMP 2A LUBE OIL PRESSURE <12 PSIG AS SENSED BY FW-187-PS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

i o FEEDWATER PUMP 2A LUBE OIL PRESSURE INDICATOR FW-203-PI.

o EMERGENCY LUBE OIL PUMP, FWP-5A STARTS.

o STANDBY LUBE OIL PUMP AUTO STARTS, FWP-3A, FWP-4A.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE STANDBY LUBE OIL PUMP AUTO STARTS.

I o VERIFY PROPER FEED PUMP LUBE OIL RESERVOIR LEVEL.

o VERIFY PROPER FEED PUMP LUBE OIL TEMPERATURE.

1 4

I l

DISCUSSION:

FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE <5 PSIG.

J

REFERENCES:

ORAWING 208-032 SHEET FW-34 SENSING ELEMENT: FW-187-PS O

l AR-504 Rev. 11 Page'10 l

c

O ENCLOSURE 1 (Page 10 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-04 L-01-04 j

F FWP A i

LUBE 0IL PUMP Z__Z TRIP i

EVENT POINT 1438 INDICATED CONDITION:

o FWP-3A BREAKER IS OPEN WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT IS ON waTH A RED FLAG ON FWP-3A CONTROL STATION.

o STANDBY FEEDWATER LUBE OIL PUMP AUTO STARTS.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE FWP-4A, BACKUP FEEDWATER LUBE OIL PUMP, IS RUNNING.

o INVESTIGATE CAUSE OF PUMP TRIP.

t DISCUSSION:

THIS PUMP SUPPLIES BOTH LUBE OIL AND CONTROL OIL TO THE FEED PUMP.

l

REFERENCES:

DRAWING 208-032 SHEET FW-07 j

SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS

>(

AR-504 Rev. 11 Page 11 l

l

ENCLOSURE I O

(Page II of 73)

{

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-04 L-01-04 l

i i

WP A LUBE OIL PUMP I

TRIP EVENT POINT 1444 INDICATED CONDITION:

o FWP-4A BREAKER IS OPEN WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

i REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

!()

o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-4A CONTROL STATION.

o FWP-3A, STANDBY FEEDWATER LUBE OIL PUMP, AUTO STARTS.

I l

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE FWP-3A, BACKUP FEEDWATER LUBE OIL PUMP IS RUNNING.

l o INVESTIGATE CAUSE OF PUMP TRIP.

i DISCUSSION:

THIS PUMP SUPPLIES BOTH LUBE OIL AND CONTROL OIL TO THE FEED PUMP.

i i

l

REFERENCES:

DRAWING 208-032 SHEET FW-09 SENSING ELEMENT: CONTROL SWITCH AND BREAKER. CONTACTS n

f AR-504 Rev. II Page 12 t

i e

l i

i l

l

\\

i i

iO ENCLOSURE 1 l

(Page 12 of 73)'

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-04 L-01-04

]

FWP A l

LUBE OIL PUMP i

ZZZ TRIP i

l i

EVENT POINT 1450 l

INDICATED CONDITION:

i l

0 FWP-5A BREAKER IS OPEN WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

l I

l REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-5A CONTROL STATION.

o FWP-3A, FWP-4A STANDBY FEEDWATER LUBE OIL PUMPS AUTO START.

i OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE BACKUP FEEDWATER LUBE OIL PUMP, FWP-3A IS RUNNING.

o IF NO LUBE DIL PUMPS ARE RUNNING, THEN VERIFY THAT FWP-2A IS NOT ROLLING.

i o INVESTIGATE CAUSE OF PUMP TRIP.

l l

DISCUSSION:

j THIS PUMP SUPPLIES ONLY BEARING LUBE OIL TO THE FEED PUMP, NOT CONTROL OIL.

I I

REFERENCES:

DRAWING 208-032 SHEET FW-34 SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS L

AR-504 Rev. 11 Page 13

I

/

ENCLOSURE 1 (Page 13 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-05 L-01-05 l

r FWP A EMERG OIL PP AUTO START EVENT POINT 1449

+

INDICATED CONDITION:

o FWP-5A BREAKER CLOSED WITH THE CONTROL HANDLE IN THE NORMAL AFTER STOP l

POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT IS ON WITH A GREEN FLAG ON FWP-5A CONTROL STATION.

i l

OPERATOR ACTIONS FOR A VALID ALARM:

I o INVESTIGATE CAUSE OF AUTO START.

l 0 VERIFY PROPER LUBE OIL SYSTEM OPERATION.

DISCUSSION:

FWP-5A WILL AUTO START WHEN LUBE OIL PRESSURE DROPS TO <12 PSIG.

FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE DROPS TO <5 PSIG.

l I

REFERENCES:

DRAWING 208-032 SHEET FW-034 SENSING ELEMENT:

CONTROL SWITCH AND BREAKER CONTACTS.

1 O

l l

AR-504 Rev. 11 Page L4

i l

'T ENCL 0SURE I (V

(Page 14 of 73)

^

i ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-05 L-01-05 1

FWP A l

EMERG OIL PP AUTO START i

EVENT POINT 1496 INDICATED CONDITION:

l o FWP-3A BREAKER CLOSED WITH THE CONTROL HANDLE IN THE NORMAL AFTER STOP POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l o RED LIGHT IS ON WITH A GREEN FLAG ON FWP-3A CONTROL STATION.

t I

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF AUTO START.

o VERIFY PROPER LUBE OIL SYSTEM OPERATION.

l DISCUSSION:

i FWP-3A WILL AUTO START WHEN LUBE OIL PRESSURE DROPS TO <I8 PSIG OR WHEN t

CONTROL OIL PRESSURE DROPS.T0.<90 PSIG.

FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE DROPS TO <5 PSIG.

l i

t

REFERENCES:

DRAWING 208-032 SHEET FW-007 l

SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS.

i AR-504.

Rev. II Page 15

i

)

O ENCLOSURE 1 (Page 15 of 73) j ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-05 L-01-05 FWP A EMERG OIL PP i

AUTO START f

EVENT POINT 1498 1

INDICATED CONDITION:

t o FWP-4A BREAKER CLOSED WITH THE CONTROL HANDLE IN THE NORMAL AFTER STOP i

POSITION.

l l

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT IS ON WITH A GREEN FLAG ON FWP-4A CONTROL STATION.

I I

i OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF AUTO START.

o VERIFY PROPER LUBE OIL SYSTEM OPERATION, i

f DISCUSSION:

FWP-4A WILL AUTO START WHEN LUBE OIL PRESSURE DROPS TO <I8 PSIG OR WHEN CONTROL OIL PRESSURE DROPS TO <90 PSIG.

l FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE DROPS TO <5 PSIG.

l l

1

REFERENCES:

DRAWING ?08-032 SHEET FW-009 SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS.

O AR-504 Rev. 11 Page 16 l

l f

ENCLOSURE I

\\

(Page 16 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-06 L-01-06 l

l FWP A LUBE OIL l

l RESVR LEVEL I

v HIGH/ LOW l

EVENT POINT 1460 INDICATED CONDITION:

t o FEEDWATER PUMP 2A LUBE OIL RESERVOIR LEVEL >33" AS SENSED BY FW-207-LS.

REDUNDANT. INDICATION WHICH WILL VERIFY ALARM:

i o LOCAL RESERVOIR SIGHT GLASS INDICATION.

1 o PUMP TRIP ALARM, PURIFIER TO FEEDWATER PUMP 2A RESERVOIR.

OPERATOR ACTIONS FOR A VALID ALARM:

o CHECK LUBE OIL FOR EVIDENCE OF WATER.

1

)

l DISCUSSION:

l IF LUBE OIL COOLER IS DETERMINED TO HAVE A SC LEAK, THEN CONSIDERATION l

SHOULD BE GIVEN TO SWAPPING THE FEED PUMP LUBE OIL COOLERS.

REFERENCES:

DRAWIi!G 208-032 SHEET FW95 SENSING ELEMENT:

FW-207-LS i

AR-504 Rev 11 Page 17 e

ENCLOSURE I O

(Page 17 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-01-06 L-01-06 FWP A LUBE OIL i

l RESVR LEVEL I

I HIGH/ LOW EVENT POINT 1461 l

l INDICATED CONDITION:

o FEEDWATER PUMP 2A LUBE OIL RESERVOIR LEVEL <18" AS SENSED BY FW-207-LS.

I i

t l

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LUBE OIL SYSTEM PRESSURE INDICATION.

o LOCAL RESERV0IR SIGHT GLASS INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

~

o CHECK LUBE OIL SYSTEM FOR EVIDENCE OF LEAKS.

o ADD OIL TO LUBE OIL RESERVOIR AS NECESSARY.

i DISCUSSION:

IF A LARGE LUBE OIL LEAK EXISTS, CONSIDERATION SHOULD BE GIVEN TO SHUTTING DOWN THE MAIN FEED PUMP.

i i

i h

l

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-207-LS i

l l

AR-504 Rev. 11 Page 18 i

l l

i

?

l l

ENCLOSURE 1 O

(Page 18 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-01 L-02-01 FWP B l

i TRIP I

I I

I I

I l

EVENT POINT 1471 l

INDICATED CONDITION:

l I

o FEEDWATER PUMP 2B CONTROL OIL PRESSURE <55 PSIG AS SENSED BY FW-136-PS2.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l o CONTROL OIL PRESSURE INDICATION.

o RED TRIP INDICATION.

o FEEDWATER PUMP SPEED INDICATOR.

OPERATOR ACTIONS FOR A VALID ALARM:

f o IF REACTOR POWER >55% RTP, THEN REFER TO AP-545.

l o IF ALL FEEDWATER HAS BEEN LOST, REFER TO AP-450.

o VERIFY PROPER OPERATION OF FEEDWATER BEARING / CONTROL OIL SYSTEMS.

j i

DISCUSSION:

[

CONDITIONS THAT WILL TRIP A MAIN FEE 0 WATER PUMP:

l TURBINE OVERSPEED (5,555 RPM)

LOSS OF TRIPPING POWER i

LOSS OF BOTH BOOSTER PUMPS LUBE OIL PRESS. <5 PSIG.

I MISSING SPEED SIGNAL <100 RPM MAIN FEEDWATER 150 ACTUATION FEED PUMP SUCT. VALVES <25% OPEN MANUAL TURBINE TRIP.

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-136-PS2 a

AR-504 Rev. 11 Page 19

ENCLOSURE 1 O.

(Page 19 of 73)

E ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-01 L-02-01 l

FWP-B TRIP l

J l

l EVENT-POINT 1493 INDICATED CONDITION:

o FEEDWATER PUMP 2B CONTROL OIL PRESSURE <55 PSIG AS SENSED BY FW-324-PS, FW-325-PS, FW-326-PS OR FW-327-PS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RPS CHANNEL A, B, C, OR D FEED PUMP TRIP AUX RELAY MFP "B" INDICATION IS l

BRIGHT.

y o RED TRIP IND!% TION.

o FEEDWATER PUMP SPEED INDICATOR.

OPERATOR ACTIONS FOR A VALID ALARM:

o IF REACTOR POWER >55% RTP, THEN REFER TO AP-545.

o IF ALL FEEDWATER HAS BEEN LOST, REFER TO AP-450..

o VERIFY PROPER OPERATION OF FEEDWATER BEARING / CONTROL OIL SYSTEMS.

DISCUSSION:

j l

THIS ALARM INDICATES THAT ONE OR MORE RPS CHANNELS HAS RECEIVED A FEED PUMP l

TRIP SIGNAL FROM THE CONTROL OIL PRESSURE SWITCHES ASSOCIATED WITH THAT FEED PUMP. THIS MAY NOT BE INDICATIVE OF AN ACTUAL FEED PUMP TRIP l

CONDITION.

i l.

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT: FW-324, 325, 326, 327-PS i.

l -

AR-504 Rev. Il Page 20 l

f ENCLOSURE 1 O

-(Page 20 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-02 L-02-02 FWP B VIBRATION HIGH EVENT POINT 1480 f

INDICATED CONDITION:

o MAIN FEEDWATER PUMP 2B OUTBOARD PUMP BEARING VIBRATION IS EITHER:

I

>3.5 MILS, (ALERT) OR, >4 MILS, (DANGER) AS SENSED BY FW-270-MIS r

REDUNDANT INDICATION WHICH WILL VERIFY ALARM-o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATIONS.

j o VIBRATION IS FELT AT FWP-28.

l OPERATOR ACTIONS FOR A VALID ALARM:

o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER PUMP OPERATION.

o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO l

REDUCING FLOW THROUGH THE PUMP UNTIL TH DANGER ALARM CAN BE CLEARED.

DISCUSSION:

i i

REFER TO OP-605 FOR V's !ATION SETPOINTS.

l THIS ALARM MUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

l t

l

REFERENCES:

DRAWING 208-032 SHEET FW-45 l

SENSING ELEMENT:

FW-270-MIS l

AR-504 Rev. II Page 21

i ENCLOSURE I ip (Page 21 of 73) v ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-02 L-02-02 i

i FWP B VIBRATION HIGH l

EVENT POINT 1481 i

INDICATED CONDITION:

o MAIN FEEDWATER PUMP 2B INBOARD TURBINE BEARING VIBRATION IS EITHER:

>2.4 MILS, (ALERT) OR, >3.5 MILS, (DANGER) AS SENSED BY FW-240-MIS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

i i

o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATIONS.

o VIBRATION IS FELT AT FWP-2B.

l I

l OPERATOR ACTIONS FOR A VALID ALARM.

o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER PUMP OPERATION.

o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO REDUCING FLOW THROUGH THE PUMP UNTIL THE DANGER ALARM CAN BE CLEARED.

l DISCUSSION:

REFER TO OP-605 FOR VIBRATION SETPOINTS.

THIS ALARM MUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION l

MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

l

REFERENCES:

DRAWING 208-032 SHEc.T FW-45 SENSING ELEMENT: FW-240-MIS O

l l

AR-504 Rev. Il Page 22 i

i

)

ENCLOSURE 1 g

(Page 22 of 73) f ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-02 L-02-02 FWP B VIBRATION HIGH

]

EVENT POINT 1482 i

INDICATED CONDITION:

o MAIN FEEDWATER PUMP 2B OUTBOARD TURBINE BEARING VIBRATION IS EITHER:

i

>2.4 MILS, (ALERT) OR, >3.5 MILS, (DANGER) AS SENSED BY FW-242-MISI.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

[

o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATIONS.

o VIBRATION IS FELT AT FWP-2B.

l OPERATOR ACTIONS FOR A VALID ALARM:

I o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER PUMP OPERATION.

o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO REDUCING FLOW THROUGH THE PUMP UNTIL THE DANGER ALARM CAN BE CLEARED.

l DISCUSSION:

1 REFER TO OP-605 FOR VIBRATION SETPOINTS.

THIS ALARM MUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

REFERENCES:

_ DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-242-MISI l

(

AR-504 Rev. II Page 23 i

i ENCLOSURE 1 O

(Page 23 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-02 L-02-02 P

FWP B VIBRATION HIGH EVENT POINT 1485 i

INDICATED CONDITION:

o MAIN FEEDWATER PUMP 2B INBOARD PUMP BEARING VIBRATION IS EITHER:

i

>3.5 MILS, (ALERT) OR, >4.0 MILS, (DANGER) AS SENSED BY FW-268-MIS.

+

1 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEEDWATER PUMP VIBRATION MONITORING PANEL INDICATIONS.

o VIBRATION IS FELT AT FWP-28.

OPERATOR ACTIONS FOR A VALID ALARM:

o IF VIBRATION IS IN " ALERT", CONTACT ENGINEERING FOR RECOMMENDATIONS FOR f

FURTHER PUMP OPERATION.

o IF VIBRATION IS IN " DANGER", THEN CONSIDERATION SHOULD BE GIVEN TO REDUCING FLOW THROUGH THE PUMP UNTIL THE DANGER ALARM CAN BE CLEARED.

I I

DISCUSSION:

t REFER TO OP-605 FOR VIBRATION SETPOINTS.

THIS ALARM MUST BE MANUALLY RESET AT THE FEEDWATER PUMP VIBRATION MONITORING PANEL WHEN THE VIBRATION CONDITION HAS CLEARED.

l

REFERENCES:

DRAWING 2n81-032 SHEET FW-45 SENSING ELEMENT:

FW-268-MIS AR-504 Rev. Il Pte 24

)

l ENCLOSURE I (Os (Page 24 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-03 L-02-03 l

FWP B OIL PRESS i

LOW i

i l

EVENT POINT 1439 l

INDICATED CONDITION:

o FEEDWATER PUMP 2B LUBE OIL PRESSURE <18 PSIG AS SENSED BY FW-191-PS.

I REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l I

i o FEEDWATER PUMP 2B LUBE OIL PRESSURE INDICATOR FW-204-PI.

J

(

o STANDBY LUBE OIL PUMP AUTO STARTS, FWP-38, FWP-48.

}

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE STANDBY LUBE OIL PUMP AUTO STARTS.

o VERIFY PROPER FEED PUMP LUBE OIL RESERVOIR LEVEL.

l o VERIFY PROPER FEED PUMP LUBE OIL TEMPERATURE.

DISCUSSION:

FEED PUMP TRIPS AT LUBE OIL PRESSURE <5 PSIG.

REFERENCES:

DRAWING 208-032 SHEET FW-08 SENSING ELEMENT: FW-191-PS

!O AR-504 Rev. 11 Page 25 w

g

6 ENCLOSURE 1

{

O (Page 25 of 73)

I ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-03 L-02-03 FWP B OIL PRESS LOW

{

i i

EVENT POINT 1440 1

INDICATED CONDITION:

5 o FEEDWATER PUMP 2B CONTROL OIL PRESSURE <90 PSIG AS SENSED BY FW-198-PS.

i REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEEDWATER PUMP 2B CONTROL OIL PRESSURE INDICATOR FW-206-PI.

o STANDBY LUBE OIL PUMP AUTO STARTi, FWP-38, FWP-48.

i OPERATOR ACTIONS FOR A VALID ALARM:

~

o ENSURE STANDBY LUBE OIL PUMP AUTO STARTS.

o VERIFY PROPER FEED PUMP LUBE OIL RESERVOIR LEVEL.

o VERIFY PROPER FEED PUMP LUBE OIL TEMPERATURE.

DISCUSSION:

l FEED PUMP CONTROL OIL SENDS A TRIP SIGNAL TO RPS WHEN CONTROL DIL PRESSURE j

IS <55 PSIG.

i

REFERENCES:

DRAWING 208-032 SHLET FW-08 SENSING ELEMENT:

FW-198-PS AR-SO4 Rev. 11 Page 26 1

ENCLOSURE 1 O

(Page 26 of 73)-

)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-03 L-02-03 i

FWP B OIL PRESS LOW EVENT POINT 1451 INDICATED CONDITION:

f 1

l o FEEDWATER PUMP 2B LUBE OIL PRESSURE <12 PSIG AS SENSED BY FW-192-PS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEEDWATER PUMP 2B LUBE OIL !?. ESSURE INDICATOR FW-204-PI.

l o EMERGENCY. LUBE OIL PUMP, FWP-5B STARTS.

o STANDBY LUBE OIL PUMP AUTO STARTS, FWP-38, FWP-4B.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE STANDBY LUBE OIL PUMP AUTO STARTS.

o VERIFY PROPER FEED PUMP LUBE OIL RESERVOIR LEVEL.

o VERIFY PROPER FEED PUMP LUBE OIL TEMPERATURE.

DISCUSSION:

FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE <5 PSIG.

l l

REFERENCES:

DRAWING 208-032 SHEET FW-35 SENSING ELEMENT:

FW-192-PS l

~

l AR-504 Rev. 11 Page 27

t i

ENCLOSURE I (Page 27 of 73) l ICS-L ANNUNCIATOR RESPONSE

.ICS-CY4-02-04 L-02-04 t

FWP B LUBE OIL PUMP ZZ TRIP l

I EVENT POINT 1441 i

INDICATED CONDITION:

o FWP-3B BREAKER IS OPEN WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

l REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-3B CONTROL STATION.

o STANDBY FEEDWATER LUBE OIL PUMP FWP-38, FWP-48, AUTO STAR.TS.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE BACKUP FEEDWATER LUBE DIL PUMP, FWP-4B IS RUNNING.

+

o INVESTIGATE CAUSE OF PUMP TRIP.

l DISCUSSION:

THIS PUMP SUPPLIES BOTH LUBE OIL AND CONTROL OIL TO THE FEED PUMP.

l l

REFERENCES:

DRAWING 208-032 SHEET FW-08 SENSING ELEMENT:

CONTROL SWITCH AND BREAKER CONTACTS AR-504 Rev. 11 Page 28 l

'O ENCLOSURE 1 O

(Page 28 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-04 L-02-04 FWP B LUBE DIL PUMP Z

Z__

TRIP EVENT POINT 1447 INDICATED CONDITION:

o FWP-4B BREAKER IS OPEN WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-4B CONTROL STATION.

i o STANDBY FEEDWATER LUBE OIL PUMP FWP-38, FWP-4B AUTO STARTS.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE BACKUP FEEDWATER LUBE OIL PUMP, FWP-3B IS RUNNING.

o INVESTIGATE CAUSE OF PUMP TRIP.

l l

DISCUSSION:

THIS PUMP SUPPLIES BOTH LUBE OIL AND CONTROL OIL TO THE FEED PUMP.

REFERENCES:

DRAWING 208-032 SHEET FW-10 l,-

SENSING ELEMENT:

CONTROL SWITCH AND BREAKER CONTACTS AR-504 Rev. II.

Page 29

1 l

ENCLOSURE 1 i

k (Page 29 of 73)

)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-04 L-02-04 i

i FWP B LUBE OIL PUMP Z

ZZ TRIP l

EVENT POINT-1453 INDICATED CONDITION:

o FWP-5B BREAKER IS OPEN WITH THE CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-5B CONTROL STATION.

o STANDBY FEEDWATER LUBE OIL PUMP FWP-3B, FWP-4B AUTO STARTS.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE BACKUP FEEDWATER LUBE OIL PUMP, FWP-3B IS RUNNING.

i o IF NO LUBE OIL PUMPS ARE RUNNING, THEN VERIFY THAT FWP-2B IS NOT ROLLING.

l o INVESTIGATE CAUSE OF PUMP-TRIP.

DISCUSSION:

r THIS PUMP SUPPLIES ONLY BEARING LUBE OIL TO THE FEED PUMP AND NOT CONTROL OIL.

l

REFERENCES:

DRAWING 20B-032 SHEET FW-35 SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS AR-504 Rev. Il P_ age 30

i 0

ENCLOSURE 1 (Page 30 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-05 L-02-05

)

FWP B EMERG OIL PP AUTO START l

l EVENT POINT 1452 I

INDICATED CONDITION:

)

o FWP-5B BREAKER CLOSED WITH THE CONTROL HANDLE IN THE NORf;AL AFTER STOP POSITION.

j REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT IS ON WITH A GREEN FLAG ON FWP-5B CONTROL STATION.

i OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF AUTO START.

o VERIFY PROPER LUBE OIL SYSTEM OPERATION.

DISCUSSION:

FWP-5B WILL AUTO START WHEN LUBE OIL PRESSURE DROPS 10 <I2 PSIG.

L FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE DROPS TO <5 PSIG.

REFERENCES:

ORAWING 20r-0V SHEET FW-035 l

SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS.

l AR-504 Rev. 11 Page 31 l

~

l l

i i

ENCLOSURE 1 t

l (Page 31 of 73) i l

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-05 L-02-05

{

WP B i

EMERG OIL PP AUTO START l

l l

EVENT POINT 1497 1

l IhDICATED CONDITION:

o FWP-3B BREAKER CLOSED WITH THE CONTROL HANDLE.IN THE NORMAL AFTER STOP POSITION.

t REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT IS ON WITH A GREEN FLAG ON FWP-3B CONTROL STATION.

i OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF AUTO START.

o VERIFY PROPER LUBE OIL SYSTEM OPERATION.

DISCUSSION:

FWP-3B WILL AUTO START WHEN LUBE OIL PRESSURE DROPS TO <I8 PSIG OR WHEN CONTROL OIL PRESSURE DROPS TO <90 PSIG.

FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE DROPS TO <5 PSIG.

REFERENCES:

DRAWING 208-032 SHEET FW-008 SENSING ELEMENT: CONTROL' SWITCH AND BREAKER CONTACTS.

Om AR-504 Rev. 11

.Page 32

ENCLOSURE 1 t '

(Page 32 of-73)

]

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-05 L-02-05 l

i FWP B EMERG OIL PP AUTO START r

EVENT POINT 1499 t

i INDICATED CONDITION:

o FWP-4B BREAKER CLOSED WITH THE CONTROL HANDLE IN THE NORMAL AFTER STOP POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT IS ON WITH A GREEN FLAG ON FWP-4B CONTROL STATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o INVESTIGATE CAUSE OF AUTO START.

o VERIFY PROPER LUBE OIL SYSTEM OPERATION.

DISCUSSION:

FWP-4B WILL AUTO START WHEN LUBE OIL PRESSURE DROPS TO <I8 PSIG OR WHEN CONTROL OIL PRESSURE DROPS TO <90 PSIG.

FEED PUMP WILL TRIP WHEN LUBE OIL PRESSURE DROPS TO <5 PSIG.

l

REFERENCES:

DRAWING 208-032 SHEET FW-010 SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS.

1 l

AR-504 Rev. II Page 33

l t

)

O ENCLOSURE'I (Page 33 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-06 L-02-06 l

l l

FWP B LUBE OIL l

RESVR LEVEL I-HIGH/ LOW 1

l l

EVENT POINT 1476 INDICATED CONDITION:

e o FEEDWATER PUMP 2B LUBE OIL RESERVOIR LEVEL >33 INCHES AS SENSED BY FW-208-LS.

t REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL RESERVOIR SIGHT GLASS INDICATION.

l 0 PUMP TRIP ALARM PURIFIER TO FEEDWATER PUMP 2B RESERVOIR.

OPERATOR ACTIONS FOR A VALID ALARM:

o CHECK LUBE OIL FOR EVIDENCE OF WATER.

l DISCUSSION:

IF LUBE OIL COOLER IS DETERMINED TO HAVE A SC LEAK, THEN CONSIDERATION SHOULD BE GIVEN TO SWAPPING THE FEED PUMP LUBE OIL COOLERS.

l l

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-208-LS i p) l Q' l

AR-504 Rev. 11 Page.34

ENCLOSURE I (Page 34 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-02-06 L-02-06 l

l 1

l FWP B LUBE OIL l

l RESVR LEVEL I

I HIGH/ LOW 2

~

EVENT POINT'1477 INDICATED CONDITION:

o FEEDWATER PUMP 2B LUBE OIL RESERVOIR LEVEL <18" AS SENSED BY FW-208-LS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL RESERVOIR SIGHT GLASS INDICATION.

o LUBE OIL SYSTEM PRESSURE INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o CHECK LUBE OIL SYSTEM FOR EVIDENCE OF LEAKS.

o ADD OIL TO LUBE OIL RESERVOIR AS NECESSARY.

DISCUSSION:

IF A LARGE LUBE OIL LEAK EXISTS, CONSIDERATION SHOULD BE GIVEN TO SHUTTING DOWN THE MAIN FEED PUMP.

I l

I

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-208-LS i

AR-504 Rev. 11 Page 35 i

l

]

i O-ENCLOSURE 1 (Page 35 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-01 L-03-01 FWBP A TRIP I

EVENT POINT 1424 r

INDICATED CONDITION:

o FWP-IA BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-IA CONTROL STATION.

o FEEDWATER FLOW INDICATION.

+

OPERATOR ACTIONS FOR A VALID ALARM:

i o IF PLANT IS >55% POWER, THEN REFER TO AP-545.

o INVESTIGATE CAUSE OF PUMP TRIP.

DISCUSSION:

THE FOLLOWING ARE B0OSTER PUMP TRIPS:

LUBE OIL PRESSURE <4 PSIG DEAERATOR LEVEL <2'10" ELECTRICAL FAULTS I

REFERENCES:

DRAWING 208-032 SHEET FW SENSING ELEMENT: CONTROL SWITCH AND BREAKER CONTACTS b

~

j

)

i AR-504 Rev. 11 Page 36

~

l

)

ENCLOSURE 1 O-(Page 36 of-73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03 j

'FWP TROUBLE l

r EVENT POINT 1434 INDICATED CONDITION:

o FEEDWATER PUMP 2A AT ZERO SPEED AND TURNING GEAR NOT ENGAGED.

~

I REDUNDANT INDI' CATION WHICH WILL VERIFY ALARM:

)

o FWP-2A SHAFT NOT TURNING.

o GREEN "NOT ENGAGED LIGHT" ON.

j OPERATOR ACTIONS FOR A VALID ALARM:

o ENGAGE FEED PUMP TURNING GEAR.

I i

I DISCUSSION:

l FWP-2A HAS NO AUTOMATIC ENGAGING FOR THE TURNING GEAR. THE TURNING GEAR l

MUST BE MANUALLY ENGAGED LOCALLY AT THE FEED PUMP.

ADMITTING GLAND STEAM TO A MAIN FEEDWATER PUMP TURBINE ROTOR WHILE IT IS STATIONARY MAY CAUSE BOWING OF THE SHAFT DUE TO UNEVEN HEATING.

REFEREyrESL DRAWING 208-032 SHEET FW-05 E

SENSING ELEMENT: TURNING GEAR ENGAGED SWITCH t

{

t AR-504 Rev. 11 Page 37 1

.I O-ENCLOSURE 1 (Page 37 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03 L-03-03 4

i FWP TROUBLE EVENT POINT 1435 i

i-i INDICATED CONDITION:

o FEEDWATER PUMP 2B AT ZERO SPEED AND TURNING GEAR NOT ENGAGED.

1 REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

i o FWP-2B SHAFT NOT TURNING.

j o GREEN "NOT ENGAGED LIGHT" IS ON.

l OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE THE FEED PUMP TURNING GEAR IS ENGAGED.

i DISCUSSION:

ADMITTING GLAND STEAM TO A MAIN FEEDWATER PUMP TURBINE ROTOR WHILE IT IS STATIONARY MAY CAUSE BOWING OF THE SHAFT DUE TO UNEVEN HEATING.

i

REFERENCES:

DRAWING 208-032 SHEET FW-06 SENSING ELEMENT: TURNING GEAR ENGAGED SWITCH O

I ll AR-504 Rev. 11 Page 38 l

3

ENCLOSURE I (Page 38 of 73) i ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE EVENT POINT 1443 INDICATED CONDITION:

o FEEDWATER PUMP 2B TURNING GEAR MOTOR AMPS >115% RATED LOAD.

f REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FWP-2B TURNING GEAR MOTOR RUNNING HOT.

OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY FWP-2B NOT RUBBING.

o CONTACT ELECTRIC SHOP.

DISCUSSION:

ADMITTING GLAND STEAM TO A MAIN FEEDWATER PUMP TURBINE ROTOR WHILE IT IS STATIONARY MAY CAUSE B0 WING 0F THE SHAFT DUE TO UNEVEN HEATING.

i i

l

REFERENCES:

DRAkING 208-032 SHEET l~J 66 l

SENSING ELEMENT: TURNING GEAR OVERLOAD CONTACT, 49-lO l

1 l

AR-504 Rev. II Page 39

ENCLOSURE 1 (Page 39 of 73) s_

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE EVENT POINT 1446 INDICATED CONDITION:

o FEEDWATER PUMP 2A TURNING GEAR MOTOR AMPS >115% RATED LOAD.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

)

o FWP-2A TURNING GEAR MOTOR HOT.

OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY FWP-2A NOT RUBBING.

o CONTACT ELECTRIC SHOP.

DISCUSSION:

ADMITTING GLAND STEAM TO A MAIN FEEDWATER PUMP TURBINE ROTOR THAT IS L

STATIONARY MAY CAUSE BOWING OF THE SHAFT DUE TO UNEVEN HEATING.

i

REFERENCES:

DRAWING 208-032 SHEET FW-05 SENSING ELEMENT: TURNING GEAR OVERLOAD CONTACT, 49 I

i AR-504 Rev. 11 Page 40

s)

ENCLOSURE 1

,(

(Page 40 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE EVENT POINT 1454 INDICATED CONDITION:

o FEEDWATER PUMP 2A TURBINE EXHAUST PRESSURE >0.0 PSIG AS SENSED BY FW-104-PS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

(' )

o MAIN TURBINE VACUUM RECORDER.

o COMPUTER POINT S-260.

o LOCAL FEED PUMP VACUUM INDICATOR.

OPERATOR ACTIONS FOR A VALID ALARM:

o CONSIDERATION SHOULD BE GIVEN TO TRIPPING THE FEED PUMP.

DISCUSSION:

OPERATION OF THE MAIN FEED PUMP AT LOW VACUUM CONDITIONS CAN CAUSE OVERHEATING 0F THE TURBINE ROTOR WHICH COULD CAUSE SUBSTANTIAL TURBINE DAMAGE, AND SO SHOULD BE MINIMIZED.

REFERENCES:

DRAWING 208-032 SHEET FW-045 7e")

SENSING ELEMENT:

FW-104-PS

\\ _.)

AR-504 Rev. 11 Page 41

l ENCLOSURE 1 i

O (Page 41 of 73)_

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 l

FWP f

TROUBLE i

r EVENT POINT 1458 INDICATED CONDITION:

i o FEEDWATER PUMP 2A TURBINE EXHAUST TEMPERATURE >230* F AS SENSED BY FW-102-TS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOW CONDENSER / FEED PUMP VACUUM.

o COMPUTER POINT S-260.

OPERATOR ACTIONS FOR A VALID ALARM:

o CONSIDERATION SHOULD BE GIVEN TO TRIPPING THE FEED PUMP.

DISCUSSION:

OPERATION OF THE MAIN FEED PUMP AT LOW VACUUM /HIGH EXHAUST TEMPERATURE CONDITIONS CAN CAUSE OVERHEATING 0F THE TURBINE ROTOR WHICH COULD CAUSE SUBSTANTIAL TURBINE DAMAGE, AND SO SHOULD BE MINIMIZED.

j i

h

REFERENCES:

DRAWING 208-032 SHEET FW-045 l

SENSING ELEMENT:

FW-102-TS O

l l.

AR-504 Rev. 11 Page 42

.I

ENCLOSURE 1 l

(s (Page 42 of 73) 1 1

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03

{

l FWP TROUBLE l

I EVENT POINT 1462 t

I l

INDICATED CONDITION:

o FEEDWATER PUMP 2A TURBINE SPEED >6,600 RPM AS SENSED BY 74-TT-AX OR 74-TT-BX, TURBINE SPEED SENSING DEVICES.

i REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

j i

o FWP-2A SPEED INDICATION.

i o FWP-2A LOCAL SPEED INDICATOR ON FEED PUMP CONTROL CONSOLE.

OPERATOR ACTIONS FOR A VALID ALARM:

o TRIP THE FEED PUMP MANUALLY.

i DISCUSSION:

OVERSPEED TRIP 0F THE FEED PUMP TURBINE SHOULD OCCUR AT 5,500 RPM.

i i

REFERENCES:

DRAWING 708-032 SHEET FW-045-SENSING ELEMENT: 74-TT-AX, 74-TT-BX AR-504 Rev. 11 Page 43

i

~

ENCLOSURE 1

(}

(Page 43 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03

+

FWP TROUBLE

{

EVENT POINT 1463 INDICATED CONDITION:

j o FEEDWATER PUMP 2A TURBINE SPEED <100 RPM AS SENSED BY 74-TM-AX OR i

74-TM-BX, TURBINE SPEED SENSING DEVICES.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

(--

o FWP-2A SPEED INDICATION.

o FWP-2A TRIP o FWP-2A LOCAL SPEED INDICATOR ON FEED PUMP CONTROL CONSOLE.

OPERATOR ACTIONS FOR A VALID ALARM.

o INCREASE TURBINE SPEED PRIOR TO RELEASING MISSING SPEED SIGNAL BYPASS START PUSHBUTTON.

DISCUSSION:

THE FEED PUMP WILL TRIP IF TURBINE SPEED DROPS TO LESS THAN 100 RPM.

1 l

i

REFERENCES:

DRAWING 208-032 SHEET FW-045

'g SENSING ELEMENT:

74-TM-AX, 74-TM-BX

, - (Q AR-504 Rev. 11 Page 44 1.

ENCLOSURE 1 O

(Page 44 of 73) g ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE EVENT POINT 1467 INDICATED CONDITION:

o FEEDWATER PUMP 2A TURBINE SHAFT ECCENTRICITY >2.4 MILS (ALERT) OR

>3.5 MILS (DANGER) AS SENSED BY FW-241-MIS 2.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEED' PUMP VIBRATION PANEL INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o IF IN ALERT, THEN CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER PUMP OPERATION.

o IF IN DANGER, THEN REDUCE TURBINE LOAD UNTIL ALARM CLEARS.

IF ALARM WILL NOT CLEAR,'THEN CONSIDERATION SHOULD BE GIVEN TO SHUTTING DOWN THE PUMP.

o MONITOR FEED PUMP BEARING TEMPERATURES ON PLANT COMPUTER.

DISCUSSION:

i SHAFT ECCENTRICITY IS THE RADIAL MOVEMENT OF THE TURBINE SHAFT CENTERLINE.

LARGE MOVEMENTS CAN CAUSE TURBINE BEARING DAMAGE DUE TO METAL TO METAL CONTACT BETWEEN THE TURBINE SHAFT AND THE BEARING SURFACE.

REFERENCES:

, DRAWING 208-032 SHEET FW-045 SENSING ELEMENT:

FW-241-MIS 2 AR-504 Rev. Il Page 45 i

i l

O ENCLOSURE 1 (Page 45 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 i

FWP 1

TROUBLE EVENT POINT 1468 i

i INDICATED CONDITION:

o FEEDWATER PUMP 2A TURBINE THRUST BEARING POSITION >10 MILS (ALERT) OR i

>20 MILS (DANGER) AS SENSED BY FW-237-KIS, REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

I

(

o FEED PUMP VIBRATION PANEL INDICATION.

OPERATOR ACTIONS FOR A VALID ALARM:

j t

o IF IN ALERT, THEN CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER PUMP OPERATION.

o IF IN DANGER, THEN REDUCE TURBINE LOAD UNTIL ALARM CLEARS.

IF ALARM WILL NOT CLEAR, THEN CONSIDERATION SHOULD BE GIVEN TO SHUTTING DOWN THE PUMP.

o MONITOR FEED PUMP BEARING TEMPERATURES ON THE PLANT COMPUTER.

DISCUSSION:

J LARGE THRUST BEARING DISPLACEMENT READINGS CAN CAUSE THRUST BEARING DAMAGE.

REFERENCES:

DRAWING 200.-032 SHEET FW-045 SENSING ELEMENT:

FW-237-KIS AR-504 Rev. 11 Page 46-l

l ENCLOSURE 1 (Page 46 of 73)-

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-S3-03 L-03-03 l

i i

FWP TROUBLE l

i EVENT POINT 1470 INDICA 7ED CCNDITION.

o FEdDi41ER f0MP-2B TURBINE EXHAUST PRESSURE >0.0 PSIG AS SENSED BY i

'Fiv-105-PS.

l REDUNDANTINDICATIONWHICHWIL[VERIFYALARM:

o MAIN TURBINE VACUUM RECOR ER.

A o COMPUTER POINT S-282.

o LOCAL FEED PUMP VACUUM INDICATOR.

f OPERATOR ACTIONS FOR A VALID ALARM:

o CONSIDERATION SHOULD BE GIVEN TO TRIPPING THE FEED PUMP.

DISCUSSION:

j OPERATION OF THE MAIN FEED PUMP AT LOW VACUUM CONDITIONS CAN CAUSE OVERHEATING OF THE TURBINE ROTOR WHICH COULD CAUSE SUBSTANTIAL TURBINE i

DAMAGE, AND SO SHOULD BE MINIMIZED.

REFERENCES:

DRAWING 208-032 SHEET FW-OtS SENSING ELEMENT:

FW-105-PS AR-504 Rev. 11 Page 47

~

i

l i

/'~')

ENCLOSURE I i

(sj/

(Page 47 of 73) i t

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 l

FWP TROUBLE EVENT POINT 1474 INDICATED CONDITION:

o FEEDWATER PUMP 2B TURBINE EXHAUST TEMPERATURE >230 F AS SENSED BY FW-103-TS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l

()

o LOW CONDENSER / FEED PUMP VACUUM.

o COMPUTER POINT S-282.

1 OPERATOR ACTIO.;S FOR A VALID ALARM:

o CONSIDERATION SHOULD BE GIVEN TO TRIPPING THE FEED PUMP.

f i

t DISCUSSION:

i OPERATION OF THE MAIN FEED PUMP AT LOW VACUUM /HIGH EXHAJ(T TEMPERATURE i

CONDITIONS CAN CAUSE OVERHEATING OF THE TURBINE ROTOR WHICH COULD CAUSE SUBSTANTIAL DAMAGE TO THE TURBINE AND S0, SHOULD BE MINIMIZED.

REFERENCES:

DRAWING 208-032 SHEET FW-045 SENSING ELEMENT: FW-103-TS AR-504 Rev. 11 Page 48

t O-ENCLOSURE 1

.i

(Page 48 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03 L-03-03 i

l I

FWP TROUBLE l

1 i

EVENT POINT 1478 INDICATED CONDITION:

l 0 FEEDWATER PUMP 2B TURBINE SPEED >6,600 RPM AS SENSED BY 74-TT-AX OR I

74-TT-BX, TURBINE SPEED SENSING DEVICES.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM.

o FWP-2B SPEED INDICATION.

o FWP-2B LOCAL SPEED INDICATOR ON FEED PUMP CONTROL CONSOLE.

l OPERATOR ACTIONS FOR A VALID ALARM-i l

0 TRIP THE FEED PUMP MANUALLY.

l l

l DISCUSSION:

9VERSPEED TRIP OF THE FEED PUMP TURBINE SHOULD OCCUR AT S,500 RPM.

i l

REFERENCES:

DRAWING 208-032 SHEET FW-045 SENSING ELEMENT: 74-TT-AX, 74-TT-BX O

~

I AR'-504 Rev. 11

_Page.49

4 ENCLOSURE I i

(Page 49 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE l

i

~

EVENT POINT 1479 l

INDICATED CONDITION:

l l

o FEEDWATER PUMP 2B TURBINE SPEED <100 RPM AS SENSED BY 74-TM-AX OR l

74-TM-BX, TURBINE SPEED SENSING DEVICES.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FWP-2B SPEED INDICATION.

o FWP-2B TRIP.

o FWP-2B LOCAL SPEED INDICATOR ON FEED P' UMP CONTROL CONSOLE.

i l

OPERATOR ACTIONS FOR A VALID ALARM:

i i

o INCREASE TURBINE SPEED PRIOR TO RELEASING MISSING SPEED SIGNAL' BYPASS START PUSHBUTTON.

l DISCUSSION:

THE FEED PUMP WILL TRIP IF TURBINE SPFED OROPS TO LESS THAN 100 RPM.

REFERENCES:

DRAWING 208-032 SHEET FW-045 C

SENSING ELEMENT:

74-TM-AX, 74-TM-BX

-(

AR-504 Rev. 11 Page 50 i

e I

l ENCLOSURE 1 I

(Page 50 of 73) s l

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 l

FWP TROUBLE I

l EVENT POINT 1483 i

i INDICATED CONDITION:

o FEEDWATER PUMP 2B TURBINE SHAFT ECCENTRICITY >2.4 MILS (ALERT) OR

>3.5 MILS (DANGER) AS SENSED BY FW-242-MIS 2.

l l

REDUNDANTINDICATIONWHICHWILLVERIF[ ALARM:

o FEED PUMP VIBRATION PANEL INDICATION.

l l

OPERATOR ACTIONS FOR A VALID ALARM:

l o IF IN ALERT, THEN CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER i

PUMP OPERATION.

l o IF IN DANGER, THEN REDUCE TURBINE LOAD UNTIL ALARM CLEARS.

IF ALARM l

WILL NOT CLEAR, THEN CONSIDERATION SHOUID BE GIVEN TO SHUTTING DOWN THE i

PUMP.

o MONITOR FEED PUMP BEARING TEMPERATURES ON THE PLANT COMPUTER.

DISCUSSION:

SHAFT ECCENTRICITY IS THE RADIAL MOVEMENT OF THE TURBINE SHAFT CENTERLINE.

LARGE MOVEMENTS CAN CAUSE TURBINE BEARING DAMAGE DUE TO METAL TO METAL CONTACT BETWEEN THE TURBINE SHAFT AND THE BEARING SURFACE.

REFERENCES:

DRAWING 208-032 SHEET FW-045 SENSING ELEMENT:

FW-242-MIS 2 O

AR-504 Rev. 11 Page 51 t

~-

ENCLOSURE I O

(Page 51 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE I

EVENT POINT 1484 i

I INDICATED CONDITION:

o FEEDWATER PUMP 2B TURBINE THRUST BEARING POSITION >IO MILS (ALERT) OR i

>20 MILS (DANGER) AS SENSED BY FW-238-KIS.

t REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FEED PUMP VIBRATION PANEL INDICATION.

l OPERATOR ACTIONS FOR A VALID ALARM:

0 IF IN ALERT, THEN CONTACT ENGINEERING FOR RECOMMENDATIONS FOR FURTHER i

PUMP OPERATION.

o IF IN DANGER, THEN REDUCE TURBINE LOAD UNTIL ALARM CLEARS.

IF ALARM i

WILL NOT CLEAR, THEN CONSIDERATION SHOULD BE GIVEN TO SHUTTING DOWN THE i

PUMP.

o MONITOR FEED PUMP BEARING TEMPERATURES ON PLANT COMPUTER.

i DISCUSSION:

(

I LARGE THRUST BEARING DISPLACEMENT READINGS CAN CAUSE THRUST BEARING DAMAGE.

REFERENCES:

DRAWING 208-032 SHEET FW-045 l

l SENSING ELEMENT:

FW-238-KIS l

l0 i

AR-504 Rev. 11 Page 52 j

e

9 i

ENCLOSURE 1

(]j

(

(Page 52 of 73) j ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE EVENT POINT 1488

(

-]

INDICATED CONDITION:

o FWP-5A MOTOR AMPS >115% RATED LOAD.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FWP-5A RUNNING HOT.

i OPERATOR ACTIONS FOR A VALID ALARM:

o START NORMAL DUTY LUBE OIL PUMP, FWP-3A OR FWP-4A, AND SECURE FWP-5A.

l DISCUSSION:

EMERGENCY LUBE OIL PUMP, FWP-5A SUPPLIES SEARING LUBE-OIL ONLY AND NOT CONTROL OIL.

r

REFERENCES:

DRAWING 208-032 SHEET FW-034 SENSING ELEMENT:

FWP-5A OVERLOAD RELAY, 49 l

AR-504 Rev. Il Page 53

i ENCLOSURE 1 (Page 53 of 73) l ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE EVENT POINT 1489 i

INDICATED CONDITION:

o FWP-58 MOTOR AMPS >115% RATED LOAD.

j l

i REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o FWP-5B RUNNING HOT.

i i

1 OPERATOR ACTIONS FOR A VALID ALARM:

j o START NORMAL DUTY LUBE OIL PUMP, FWP-3B OR FWP-48 AND SECURE FWP-5B.

l l

l DISCUSSION:

EMERGENCY LUBE OIL PUMP, FWP-5B SUPPLIES BEARING OIL ONLY AND NOT CONTROL OIL.

REFERENCES:

DRAWING 208-032 SHEET FW-035 SENSING ELEMENT:

FWP-5B OVERLOAD RELAY, 49-O l

AR-504 Rev. 11 Page 54 1

m o

nr-+

ENCLOSURE 1-(Page 54 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE 1

EVENT POINT 1490 INDICATED CONDITION:

o FEEDWATER PUMP 2A TACH 0 METER SELECT AND TEST SWITCH NOT IN NORMAL i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o WHITE TRIP " BLOCK" LIGHT IS ON, LOCATED ON THE FWP-2A LOCAL CONTROL PANEL ON.

l l

OPERATOR ACTIONS FOR A VALID ALARM:

i o VERIFY FEEDWATER PUMP TESTING IS IN PROGRESS.

o PLACE " TACHOMETER SELECT AND TEST" SWITCH BACK TO NORMAL.

l

[

DISCUSSION:

THIS ALARM INDICATES THAT THE FEED PUMP TEST SWITCH IS IN THE TEST POSITION. THIS BLOCKS ALL TRIPS TO THE MAIN FEED PUMP.

1

REFERENCES:

DRAWING 208-032 SHEET FW-045 _

SENSING ELEMENT:

FW-139-PS AND FW-141-PS O

AR-504 Rev. 11

.Page 55 j

il-

1 O'

ENCLOSURE I (Page 55 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 i

FWP TROUBLE l

EVENT-POINT 1491 INDICATED CONDITION:

o FEEDWATER PUMP 2B TACHOMETER SELECT AND TEST SWITCH NOT_IN NORMAL l

l REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o WHITE TRIP " BLOCK" LIGHT IS ON, LOCATED ON THE FWP-28 LOCAL CONTROL PANEL ON.

l OPERATOR ACTIONS FOR A VALID ALARM:

l o VERIFY FEEDWATER PUMP TESTING IS IN PROGRESS.

l o PLACE " TACHOMETER SELECT AND TEST" SWITCH BACK TO NORMAL.

l DISCUSSION:

i THIS ALARM INDICATES THAT THE FEED PUMP TEST SWITCH IS IN THE TEST POSITION. THIS BLOCKS ALL TRIPS TO THE MAIN FEED PUMP.

1

REFERENCES:

DRAWING 208-032 SHEET FW-045 SENSING ELEMENT:

FW-140-PS AND FW-142-PS lO l

l AR-SO4 Rev. II Page 56

P

(~

ENCLOSURE 1 1

(Page 56 of 73)

C ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP TROUBLE t

EVENT POINT 1494 i

l INDICATED CONDITION:

o FEEDWATER PUMP 2A LUBE OIL FILTER DIFFERENTIAL PRESSURE >20 PSID AS SENSED BY FW-201-PS.

l REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL DIFFERENTIAL PRESSURE INDICATOR.

o LUBE OIL PRESSURE LOW.

i OPERATOR ACTIONS FOR A VALID ALARM:

o SWAP FWP-2A LUBE OIL FILTERS.

j DISCUSSION:

MAXIMUM DIFFERENTIAL PRESSURE ACROSS FEEDWATER PUMP LUBE OIL FILTER IS 20 PSID. THIS IS TO PROTECT THE FILTERS FROM MECHANICAL DAMAGE DUE'T0'HIGH DIFFERENTIAL PRESSURES.

INTERNAL RELIEF VALVE LIFTS AT 20 PSID.

l

REFERENCES:

DRAWING 208-032 SHEET FW-045 SENSING ELEMENT:

FW-201-PS 1

AR-504 Rev. 11 Page 57

i i

O ENCLOSURE 1 (Page 57 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-03 L-03-03 FWP-TROUBLE EVENT POINT 1495 INDICATED CONDITION:

o FEEDWATER PUMP 2B LUBE OIL FILTER DIFFERENTIAL PRESSURE >20 PSID AS-SENSED BY FW-201-PS.

l 1

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL DIFFERENTIAL PRESSURE INDICATOR.

o LUBE OIL PRESSURE LOW.

l OPERATOR ACTIONS FOR A VALID ALARM:

l l

o SWAP FWP-2B LUBE OIL FILTERS.

l l

l DISCUSSION:

[

MAXIMUM DIFFERENTIAL PRESSURE ACROSS FEEDWATER PUMP LUBE OIL FILTER IS 20 PSID. THIS IS TO PROTECT THE FILTERS FROM MECHANICAL DAMAGE DUE TO HIGH DIFFERENTIAL PRESSURES.

INTERNAL RELIEF VALVE LIFTS AT 20 PSID.

l I

REFERENCES:

DRAWING 208-032 SHEET FW-045 SENSING ELEMENT:

FW-202-PS s

l AR-504 Rev. 11 Page 58

ENCLOSURE I O

(Page 58 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-04 L-03-04 FWP BRG OIL DRAIN TEMP ZZ HIGH-EVENT POINT 1456 l

INDICATED CONDITION:

o FEEDWATER PUMP 2A TURBINE BEARING #1 LUBE OIL DRAIN TEMPERATURE >I70' F.

AS SENSED BY FW-143-TS.

REDUNDANT INDICATION WHICH WILL VERI'FY ALARM:

o LOCAL FEEDWATER PUMP BEARING TEMPERATURE INDICATORS.

o FEEDWATER PUMP 2A COMPUTER GROUP 89.

OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY PROPER COOLING WATER FLOW.

o CONTACT ENGINEERING CONCERNING CONTINUED FEEDWATER PUMP OPERATION.

o CONSIDERATION SHOULD BE GIVEN TO REDUCING FEEDWATER PUMP LOAD.

l l

DISCUSSION:

MAXIMUM BEARING OIL OUTLET TEMPERATURE IS 175' F TO PREVENT BREAKDOWN IN LUBE OIL VISCOSITY THAT COULD LEAD TO BEARING DAMAGE.

MAXIMUM BEARING TEMPERATURE IS 200' F.

REFERENCES:

DRAWING 208-032 SHEET FW-45 l

SENSING ELEMENT:

FW-143-TS lO l

l AR-504 Rev. 11 Page 59 l

(

l l

l O

ENCLOSURE I (Page 59 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-04 L-03-04 i

FWP BRG OIL DRAIN TEMP i

HIGH i

EVENT POINT 1457 l

i INDICATED CONDITION:

o FEEDWATER PUMP 2A TURBINE BEARING #2 LUBE OIL DRAIN TEMPERATURE >170 F.

AS SENSED BY FW-144-TS.

l REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL FEEDWATER PUMP BEARING TEMPERATURE INDICATORS.

i o FEEDWATER PUMP 2A COMPUTER GROUP 89.

i OPERATOR ACTIONS FOR A VALID ALARM:

l o ENSURE PROPER COOLING WATER FLOW.

o CONTACT ENGINEERING CONCERNING CONTINUED FEEDWATER PUMP OPERATION.

o CONSIDERATION SHOULD BE GIVEN TO REDUCING FEEDWATER PUMP LOAD.

DISCUSSION:

l MAXIMUM BEARING OIL OUTLET TEMPERATURE IS 175* F TO PREVENT BREAKDOWN IN LUBE OIL VISCOSITY-THAT COULD LEAD TO BEARING DAMAGE.

MAXIMUM BEARING TEMPERATURE IS 200* F.

l

REFERENCES:

DRAWING 208-032 SHEET FW-45 l SENSING ELEMENT:

FW-144-TS AR-504 Rev. 11 Page 60-

ENCLOSURE 1 (Page 60 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-04 L-03-04 FWP BRG OIL i

DRAIN TEMP Z

HIGH

-o 3

y EVENT POINT 1472 1

I INDICATED CONDITION:

o FEEDWATER PUMP 2B TURBINE BEARING #1 LUBE OIL DRAIN TEMPERATURE >170* F.

AS SENSED BY FW-145-TS.

t i

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l o LOCAL FEEDWATER PUMP BEARING TEMPERATURE INDICATORS.

i j

o FEEDWATER PUMP 2B COMPUTER GROUP 90.

l l

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE PROPER COOLING WATER FLOW.

o CONTACT ENGINEERING CONCERNING CONTINUED FEEDWATER PUMP OPERATION.

o CONSIDERATION SHOULD BE GIVEN TO REDUCING FEEDWATER PUMP LOAD.

l DISCUSSION:

MAXIMUM BEARING OIL OUTLET TEMPERATURE IS 175* F TO PREVENT BREAKDOWN IN I

LUBE OIL VISCOSITY THAT COULD LEAD TO BEARING DAMAGE.

l MAXIMUM BEARING TEMPERATURE IS 200* F.

l

REFERENCES:

DRAWING 208-032 SHEET FW-45 SENSING ELEMENT:

FW-145-TS 7

, (V l

AR-504 Rev. II Page 61

l l

ENCLOSURE 1 (Page 61 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-04 L-03-04 FWP BRG OIL DRAIN TEMP HIGH l

EVENT POINT 1473 1

INDICATED CONDITION:

o FEEDWATER PUMP 2B TURBINE BEARING #2 LUBE OIL DRAIN-TEMPERATURE >I70 F.

AS SENSED BY-FW-146-TS.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l o LOCAL FEEDWATER PUMP BEARING TEMPERATURE INDICATORS.

j o FEEDWATER PUMP 2B COMPUTER GROUP 90.

l OPERATOR ACTIONS FOR A VALID ALARM:

I o VERIFY PROPER COOLING WATER FLOW.

o CONTACT ENGINEERING CONCERNING CONTINUED FEEDWATER PUMP OPERATION.

o CONSIDERATION SHOULD BE GIVEN TO REDUCING FEEDWATER PUMP LOAD.

i DISCUSSION:

j MAXIMUM BEARING OIL OUTLET TEMPERATURE IS 175 F TO PREVENT BREAKDOWN IN LUBE OIL VISCOSITY THAT COULD LEAD TO BEARING DAMAGE.

MAXIMUM BEARING TEMPERATURE IS 200* F.

REFERENCES:

DRAWING 208-0",, SHEET FW-45 SENSING ELEMENT:

FW-146-TS O

l f

AR-504 Rev. 11 Page 62 I

l

I ENCLOSUR O (Page 62 of-73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-05 L-03-05 FWP OIL CLR OUTLET TEMP HIGH EVENT POINT 1459 l

INDICATED CONDITION:

o FEEDWATER FUMP 2A LUBE OIL COOLER OUTLET -TEMPERATURE >I40* F. AS SENSED BY FW-211-TS.

j REDUNDANT INDICATION WHICH WILL VERIFY ALARM-o LOCAL FEEDWATER PUMP LUBE OIL COOLER OUTLET TEMPERATURE. INDICATORS.

o FEEDWATER PUMP 2A COMPUTER GROUP 89.

OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY PROPER COOLING WATER FLOW.

o CONTACT ENGINEERING CONCERNING CONTINUED FEEDWATER PUMP OPERATION.

o CONSIDERATION SHOULD BE GIVEN TO REDUCING FEEDWATER PUMP LOAD.

DISCUSSION:

MAXIMUM BEARING OIL OUTLET TEMPERATURE IS 175* F TO PREVENT BREAKDOWN IN LUBE OIL VISCOSITY THAT COULD LEAD TO BEARING DAMAGE.

MAXIMUM BEARING TEMPERATURE IS 200* F.

REFERENCES:

DRAWING 208-032' SHEET FW-45 SENSING ELEMENT:

FW-211-TS AR-504 Rev. 11 Page 63

I O

ENCLOSURE I (Page 63 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-05 L-03-05 l

FWP OIL CLR OUTLET TEMP l

HIGH l

EVENT POINT 1475 INDICATED CONDITION:

o FEEDWATER PUMP 2B LUBE OIL COOLER OUTLET TEMPERATURE >I40* F. AS SENSED l

BY FW-212-TS.

i

~

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o LOCAL FEEDWATER PUMP LUBE OIL COOLER OUTLET TEMPERATURE INDICATORS.

o FEEDWATER PUMP 2B COMPUTER GROUP 90.

OPERATOR ACTIONS FOR A VALID ALARM:

1 o VERIFY PROPER COOLING WATER FLOW.

o CONTACT ENGINEERING CONCERNING CONTINUED FEEDWATER PUMP OPERATION.

o CONSIDERATION SHOULD BE GIVEN TO REDUCING FEEDWATER PUMP LOAD.

l DISCUSSION:

MAXIMUM BEARING OIL OUTLET TEMPERATURE IS 175* F TO PREVENT BREAKDOWN IN LUBE OIL VISCOSITY THAT COULD LEAD TO BEARING DAMAGE.

MAXIMUM BEARING TEMPERATURE IS 200* F.

l

REFERENCES:

DRAWING 208-032 SHEET FL'-45 SENSING ELEMENT:

FW-212-TS

.AR-504 Rev. II Page 64 l

O' ENCLOSURE 1 (Page 64 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-06 L-03-06 l

l (MSV-53/

I l

MSV-54)

I I

NOT FULL OPEN l

Z EVENT POINT 0941 t

INDICATED CONDITION:

o TURBINE BYPASS ISOLATION VALVE MSV-53, NOT' FULL OPEN.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o MSV-53 POSITION INDICATION.

o LOCAL POSITION.

OPERATOR ACTIONS FOR A VALID ALARM:

o DETERMINE REQUIREMENT FOR MSV-53 NOT BEING FULL OPEN.

o OPEN MSV-53.

i DISCUSSION:

l l

MSV-53 ISOLATES STEAM GENERATOR "A" TURBINE BYPASS VALVES (MSV-9, MSV-10) i AND THE FWP-2A HP STEAM SUPPLY.

REFERENCES:

DRAWING 208-039 SHEET MS-01 SENSING ELEMENT:

33 0 VALVE OPEN CONTACT AR-504 Rev. II Page 65

i ENCLOSURE I (Page 65 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-03-06 L-03-06 I

l l

l l

l (MSV-53/

l l

MSV-54)

I I

NOT FULL OPEN I

EVENT POINT 0942 I

INDICATED CONDITION:

j l

o TURBINE BYPASS ISOLATION VALVE MSV-54, NOT FULL OPEN.

f REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l l

o MSV-54 POSITION INDICATION.

o LOCAL POSITION.

OPERATOR ACTIONS FOR A VALID ALARM:

i o DETERMINE REQUIREMENT FOR MSV-54 NOT BEING FULL OPEN.

o OPEN MSV-54.

DISCUSSION:

MSV-54 ISOLATES STEAM GENERATOR "B" TURBINE BYPASS VALVES (MSV-11, MSV-14)

AND THE FWP-28 HP STEAM SUPPLY.

REFERENCES:

DRAWING 208-039 SHEET MS-02 SENSING ELEMENT: 33 0 VALVE OPEN CONTACT l

(

AR-504 Rev. 11 Page 66 l-

/

ENCLOSURE 1 (Page 66 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-01 L-04-01 i

FWBP B TRIP EVENT POINT 1425 l

INDICATED CONDITION:

I o FWP-1B BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START l

POSITION.

REDUNDANTINDICATIONWHICHWILLV5RIFYALARM:

o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-1B CONTROL STATION.

j o FEEDWATER FLOW INDICATION.

I OPERATOR ACTIONS FOR A VALID ALARM:

l o IF REACTOR POWER IS >55% RTP, THEN REFER TO AP-545.

c INVESTIGATE CAUSE OF PUMP TRIP.

l l

DISCUSSION:

THE FOLLOWING ARE B0OSTER PUMP TRIPS:

LUBE OIL PRESSURE <4 PSIG DEAERATOR LEVEL <2'10" ELECTRICAL FAULTS-

REFERENCES:

DRAWING 208-032 SHEET FW-02 SENSING ELEMENT:

CONTROL SWITCH AND BREAKER CONTACTS

!~

AR-504 Rev. 11 Page 67 i

i i

ENCLOSURE I O

(Page 67 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-02 L-04-02 FEP MOTOR OVERLOAD EVENT POINT 1486 INDICATED CONDITION:

o FWP-1A MOTOR AMPS >115% RATED LOAD.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

l()

o FWP-1A CURRENT INDICATOR.

o FEEDWATER FLOW INDICATION.

o FWP-1A TRIPS.

OPERATOR ACTIONS FOR A VALID ALARM:

o REDUCE FEEDWATER FLOW.

o HAVE BREAKER CHECKED FOR DROPPED TARGETS.

i DISCUSSION:

l THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR THE INSTANTANE0US OVERCURRENT PROTECTIVE DEVICES HAVE ACTUATED.

INSTANTANEOUS OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.

IT IS POSSIBLE TO HAVE THIS ALARM PRIOR TO THE BREAKER TRIP.

l RCCFRENCES: DRAWING 208-032 SHEET FW-01 i

[}

_ SENSING ELEMENT: BREAKER OVER CURRENT RELAYS AR-504 Rev. 11 Page 68

i ENCLOSURE 1 O

(Page 68 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-02 L-04-02 FWBP MOTOR OVERLOAD EVENT POINT 1487 INDICATED CONDITION:

o FWP-1B MOTOR AMPS >115% RATED LOAD.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

i

.o FWP-1B CURRENT INDICATOR.

o FEEDWATER FLOW INDICATION.

o FWP-1B TRIPS.

i OPERATOR ACTIONS FOR A VALID ALARM:

o REDUCE FEEDWATER FLOW.

o HAVE BREAKER CHECKED FOR DROPPED TARGETS.

DISCUSSION:

THIS ALARM INDICATES THAT EITHER THE TIMED OVERCURRENT OR THE INSTANTANE0US l

0VERCURRENT PROTECTIVE DEVICES HAVE ACTUATED.

INSTANTANE0US OVERCURRENT PROTECTIVE RELAY ACTUATION WILL TRIP THE BREAKER.

IT IS POSSIBLE TO HAVE THIS ALARM PRIOR TO THE BREAKER. TRIP.

REFERENCES:

DRAW W.~. 208-032 SHEET FW-02 SENSING ELEMENT:

BREAKER OVER CURRENT RELAYS i

AR-504 Rev. 11 Page 69

i 7

O ENCLOSURE I (Page 69 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-03 L-04-03 FWBP LUBE OIL PUMP i

TRIP EVENT POINT 1426 1

INDICATED CONDITION:

o FWP-6A BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-6A CONTROL STATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE FWP-IA LUBE OIL PRESSURE NORMAL.

o INVESTIGATE CAUSE OF PUMP TRIP.

l i

l i

l DISCUSSION:

THE BOOSTER PUMP HAS A SHAFT DRIVEN LUBE OIL PUMP THAT SUPPLIES OIL PRESSURE WHILE THE B00 STER PUMP IS RUNNING.

l

REFERENCES:

DRAWING 208-032 SufET FW-03 SENSING ELEMENT:

BREAKER AND CONTROL SWITCH CONTACTS.

lO.

I AR-504 Rev. 11 Page 70 l

! ('~

ENCLOSURE I l(

(Page 70 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-03 L-04-03 i

FWBP LUBE OIL PUMP TRIP EVENT POINT 1427 l

INDICATED CONDITION:

I o FWP-6B BREAKER OPEN WITH CONTROL HANDLE IN THE NORMAL AFTER START POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

V o GREEN LIGHT IS ON WITH A RED FLAG ON FWP-6B CONTROL STATION.

OPERATOR ACTIONS FOR A VALID ALARM:

o ENSURE FWP-IB LUBE OIL PRESSURE NORMAL.

o INVESTIGATE CAUSE OF PUMP TRIP.

DISCUSSION:

THE B00 STER PUMP HAS A SHAFT DRIVEN LUBE OIL PUMP THAT SUPPLIES OIL PRESSURE WHILE THE B0OSTER PUMP IS RUNNING.

REFERENCES:

DRAWING 208-032 SHEET FW 04 es SENSING ELEMENT: BREAKER AND CONTROL SWITCH CONTACTS.

b AR-504 Rev. II Page 71

~

ENCLOSURE I (Page 71 of 73)

ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-04 L-04-04 i

FWBP i

LUBE OIL PUMP Z____

AUTO START EVENT POINT 1428 l

INDICATED CONDITION:

l o FWP-6A BREAKER CLOSED WITH THE CONTROL STATION IN THE NORMAL-AFTER STOP POSITION.

~

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT IS ON WITH A GREEN FLAG ON THE FWP-6A CONTROL STATION.

{

l OPERATOR ACTIONS FOR A VALID ALARM:

l o VERIFY PROPER FEEDWATER B00 STER PUMP OIL PRESSURE.

i o VERIFY PROPER FEEDWATER B00 STER PUMP LUBE OIL RESERVOIR LEVEL.

DISCUSSION:

FWP-6A WILL AUTO START IF FWP-IA LUBE OIL PRESSURE DROPS TO <5 PSIG.

REFERENCES:

DRAWING 208-032 SHEET FW-03 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS O

AR-504 Rev. 11 Page 72

6

('

ENCLOSURE I

(

(Page 72 of 73) i ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-04 L-04-04 FWBP LUBE OIL PUMP ZZZ AUTO START j

I EVENT POINT 1429 i

INDICATED CONDITION:

i I

l o FWP-6B BREAKER CLOSED WITH THE CONTROL STATION IN THE NORMAL AFTER STOP POSITION.

REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

o RED LIGHT IS ON WITH A GREEN FLAG ON THE FWP-6B CONTROL STATION.

l OPERATOR ACTIONS FOR A VALID ALARM:

o VERIFY PROPER FEEDWATER B00 STER PUMP OIL PRESSURE.

o VERIFY PROPER FEEDWATER B0OSTER PUMP LUBE OIL RESERVOIR LEVEL.

I l

DISCUSSION:

FWP-6B WILL AUTO START IF FWP-IB LUBE OIL PRESSURE DROPS TO <5 PSIG.

REFERENCES:

DRAWING 208-032 SHEET FW-04 SENSING ELEMENT: CONTROL STATION AND BREAKER CONTACTS AR-504 Rev. II Page 73

l 1

ENCLOSURE I

(

(Page 73 of 73) t ICS-L ANNUNCIATOR RESPONSE ICS-CY4-04-05 L-04-05 a

FWP SEAL POT LEVEL r

LOW l

[

EVENT POINT 1252 INDICATED CONDITION:

l 0 MAIN FEEDWATER PUMP SEAL DRAIN RETURN POT LEVEL <7 3/8" AS SENSED BY GW-36-LS REDUNDANT INDICATION WHICH WILL VERIFY ALARM:

j o LOCAL DRAIN POT SIGHTGLASS.

i OPERATOR ACTIONS FOR A VALID ALARM:

I o VERIFY DRAIN POT LEVEL CONTROL VALVE, GWV-6 IS CLOSED, IF NOT, l

CONSIDERATION SHOULD BE GIVEN TO ISOLATING GWV-6 BY CLOSING EITHER d

GWV-33 OR GWV-34 AND CONTROLLING DRAIN POT LEVEL USING GWV-6 BYPASS VALVE GWV-35.

DISCUSSION:

l A LOSS OF LEVEL IN THE DRAIN POT CAN LEAD TO A LOSS OF MAIN CONDENSER VACUUM.

REFERENCES:

DRAWING 208-034 SHEET GW-04 SENSING ELEMENT: GW-36-LS O

{

j AR-504 Rev. II Page 74 (LAST PAGE)