TECHNICAL SPECIFICATION CHANGE REOUEST 162 SAFETY EVALUATION INTRODUCTION Wisconsin Electric Power Company (Licensee) is applying for amendments to Facility Operating License DPR-24 and DPR-27 for Point Beach Nuclear Plant, Units 1 and 2.
The requested amend-ments propose changes to Technical Specification 15.3.1.A.3,
" Components Required For Redundant Decay Heat Removal Capa-bility," and its associated bases.
The requested amendments are in response to the NRC Notice of Violation included in an NRC letter from Mr. A.
Bert Davis, dated August 4, 1992.
Our response to the Notice of Violation, contained in our letter to the NRC dated September 3, 1992, contained a commitment to propose amendments to the Technical Specifications relative to decay heat removal (DHR) operation with reactor coolant system temperature less than 350*F.
EVALUATION l
The proposed changes will clarify the wording of Technical i
Specification 15.3.1.A.3.a.(3) by deleting words which were open to interpretation, and rewrite the specification in a manner consistent with NRC guidance and with Westinghouse Standard Technical Specifications (STS).
The words proposed in this amendments request were previously recommended by the NRC in a letter to licensees of all PWRs dated June 11, 1980, requesting amendment of Technical Specifications to ensure redundancy of DHR capability in all modes of operation.
The June 11, 1980, NRC letter transmitted model Technical Specifications which the NRC staff believed would provide adequate measures to ensure redundancy of DHR capability.
l The proposed changes clarify the " testing" exemption of Technical l
Specification 15.3.1.A.3.a.(3) by adopting STS terminology which states:
"All reactor coolant pumps and residual heat removal pumps may be deenergized up to one hour provided:
- 1) no operations are permitted that would cause the dilution of reactor coolant system boron concentration, and 2) core outlet temperature is maintained at least 10*F below saturation temperature."
The exemption pointedly addresses the two concerns which exist when all circulation, via either the reactor coolant pumps or residual heat removal loops, are secured:
- 1) that no operations 1
9303040320 930226 PDR ADOCK 05000266 P
be allowed which could affect reactivity changes in the form of boron concentration changes, and 2) that conditions are main-tained such that boiling will not occur in the reactor core as monitored by core outlet temperature in comparison to saturation temperature.
In addition, wording has been added to the PBNP Technical Specification Basis (taken from Westinghouse Standard Technical Specifications) which discuss the mixing function of the reactor coolant pumps or RHR pumps in the shutdown configuration as being instrumental in preventing boron stratification as well as producing gradual reactivity changes during boron concentration reductions in the reactor coolant system.
We have also added an additional restriction to require the l
1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> exemption to be take place only within any 8 hour9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> period.
1 1
1
-1 CONCLUSIONS l
I In summary, the proposed changed to the PBNP Technical Speci-I fications will provide clarity regarding decay heat removal system operation with the reactor in the shutdown configuration, and reactor coolant system temperature less than 350*F, by clearly stating the conditions under which all coolant recir-culation pumps (reactor coolant pumps and residual heat removal pumps) may be secured.
The proposed changes are consistent with published NRC guidance and with Westinghouse Standard Technical Specifications.
Therefore, the proposed revisions will ensure and enhance the continued safe operation of the Point Beach Nuclear Plant.
1 1
2
l.
IECHNICAL SPECIFICATION CHANGE RE0 DEST 162 "NO SIGNIFICANT HAZARDS CONSIDERATION" l
In accordance with the requirements of 10 CFR 50.91(a), Wisconsin Electric Power Company (Licensee) has evaluated the proposed changes against the standards of 10 CFR 50.92 and has determined that the operation of Point Beach Nuclear Plant, Units 1 and 2, l
in accordance with the proposed amendments, does not present a significant hazards consideration.
A proposed facility operating license amendment does not present a significant hazards consideration if operation of the fac.llity in accordance with the proposed amendment will not:
1.
Create a significant increase in the probability or consequences of an accident previously evaluated; or l
2.
Create the possibility of a new or different kind of accident from any accident previously evaluated; or 3.
Will no'. Create a significant reduction in a margir. of safety.
Criterion 1 The residual heat removal (RHR) system at PBNP serves two purposes to the shutdown reactor:
l 1.
The system removes decay heat from the reactor core to l
allow cooldown of a subcritical unit once reactor i
coolant system temperature is less than 350*F.
2.
Provides a system to ensure mixing of the reactor coolant system volume when the reactor coolant pumps are secured.
The system is not involved in the initiation of any analyzed accidents as documented in the PBNP FSAR.
Hence, the changes proposed cannot create an increase in the probability of such events.
However, the system is involved in mitigating the consequences of evaluated accidents through the removal of decay heat.
The proposed changes will introduce and allow a short time period (1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />) during normal shutdown operations when all reactor coolant pumps and residual heat removal pumps may be de-energized.
While this relaxation is significant, the provisions for this relaxation, as well as the short period of time allowed, sufficiently address the functions which the RHR system (or operable reactor coolant systec J oop) provide to a 1
shutdown reactor core when temperature is less than 350:?; that is:
- 1) no operations are permitted which could cause a dilution of reactor coolant system boron concentration (thus inserting positive reactivity), and 2) maintenance of reactor coolant system temperature such that subcooling of at least 10*F exists, ensuring boiling does not occur in the shutdown core.
The brevity of the relaxation, combined with the two restrictive provisions cited, is sufficient to maintain the probability or consequences of previously analyzed accidents as being unaffected.
Criterion 2 The relaxation of the requirement to have one decay heat removal method in operntion in no way introduces any new criteria to system operation s0ch that any new or different kind of' accident from any accident previously evaluated is created.
Securing of the decay heat removai. methods under the tight provisions allowed cannot create the possibility of a new or different accident because reactor reactivity remains unaffected and the reactor coolant system is maintained in a subcooled configuration during the brief time allowed.
Criterion 3 As stated above, both the brevity of the relaxation as well as the strict provisions which must be in effect during the brief period of relaxation, support the fact that a significant reduction in a margin of safety will not be introduced.
The NRC has previously analyzed and accepted the proposed wording in its generic documents.
Operation of PBNP in accordance with these proposed amendments cannot create an increase in the probability or consequences of an accident previously evaluated, create a new or different kind of accident, or result in a significant reduction in a margin of safety.
Therefore, the proposed changes do not present a significant hazards consideration.
I 2
15.3 LIMITING CONDITIONS FOR OPERATION 15.3.1 REACTOR COOLANT SYSTEM i
Apolicability Applies to the operating status of the Reactor Coolani System.
i Obiective To specify those limiting conditions for operation of the Reactor Coolant System which must be met to ensure safe reactor operation.
Specification I
A.
OPERATIONAL COMPONENTS 1.
Coolant Pumps
- i a.
When the reactor is critical, except for tests, at least one reactor coolant pump shall be in operation.
(1) Reactor power shall not be maintained above 3.5% of rated power unless both reactor coolant pumps are in operation.
(2)
If either reactor coolant pump ceases operating, immediate power reduction shall be initiated under aiministrative control as necessary to reduce power to less than 3.5% of rated power.
(3)
If both reactor coolant rumps cease operating and power is greater than 3.5% of rated power, but less than 10% of rated power, reactor shutdown will commence immediately and verify the reactor trip breakers are opened within one hour.
b.
When the reactor is subcritical and the average reactor coolant temperature is greater than 350*F, except for tests, at least one reactor coolant pump shall be in operation.
(1) Both reactor coolant pumps may be deenergized provided.
a.
No operations are permitted that would cause dilution of the reactor coolynt system boron concentration, b.
Core outlet temperature is maintained at least 10*F below saturation temperature, and c.
The reactor trip breakers are open.
c.
At least one reactor coolant pump or residual heat removal system shall be in operation when a reduction is made in the boron con-centration of the reactor coolant.
2.
- a.
One steam generator shall be operable whenever the average reactor i
coolant temperature is above 350*F.
3.
Components Required for Redundant Decay Heat Removal Capability
- l a.
Reactor coolant temperature less than 350*F and greater than 140*F.
(1) At least two of the decay heat removal methods listed shall be operable.
(a) Reactor Caolant Loop A, its associated steam generator dnd either reactor coolant pump (b) Reactor Coolant Loop B, its associated steam generator and either reactor coolant pump
- Applica!,le only when one or more fuel assemblics are in the reactor vessel.
{
Unis 1 - Amendment No.103 15.3.1-1 July 23, 1986 Unit 2 - Amendment No. 106
l k
i (c) Residual Heat Removal Loop (A)*
(d) Residual Heat Removal loop (m *
(2)
If the conditions of specification (1) above cannot be met, corrective action to return a second decay heat removal method to operable status as soon as possible shall be initiated immediately.
(4)(3)l If no decay heat removal method is in operation, _xce_ptVa_s e
perniittedjbfi(4){bsloy all operations causing an~iiicr,Fii6 in the reactor decay heat load or a reduction in reactor coolant system boron concentration shall be suspended. Corrective actions to return a decay heat removal method to operation i
shall be initiated immediately.
I t3)(4)_
At least one of the above decay heat removal methods shall be in operation. cxcept when required to be secured for testing.
~(a)RAll?FiscthRsislidtTp'iiiiiiiTEd7Fssidus14sitTFum691@shijis mayj beTdeenergized)forJupito:11 houri (l_)hNoioperationnaFe(pefmittedfth)provid tswciuld ron concentratibnhand-
~ ~ ~ ~ ~ " ^ "
- (2)][ Core-out1et]temperiJEFe y si(ATh iGi3}iQlEi W N y bel.ow saturat.ionjtemperature b.
Reactor Coolant Temperature Less Than 140*F (1) Beth residual heat removal loops shall be operable except as l
permitted in items (3) or (4) below.
~
(2)
If no residual heat removal loop is in operation, all operations causing an increase in the reactor decay heat load or a reduction in reactor coolant system boron concentration i
shall be suspended. Corrective actions to return a decay heat removal method to operation shall be initiated immediately.
(3) One residual heat removal loop may be out of service when the i
reactor vessel head is removed and the refueling cavity flooded.
(4) One of the two residual heat removal loops may be temporarily out of service to meet surveillance requirements.
4.
Pressurizer Safety Valves I
a.
At least one pressurizer safety valve shall be operable whenever the reactor head is on the vessel.
b.
Both pressurizer safety valves shall be operable whenever the reactor is critical.
i
- Mechanical design provisions of the residual heat removal system afford the necessary flexibility to allow an operable residual heat removal loop to con-sist of the RHR pump from one loop coupled with the RHR heat exchanger from i
the other loop.
Electrical design provisions of the residual heat removal l
system afford the necessary flexibility to allow the normal or emergency power i
source to be inoperable or tied together when the reactor coolant temperature is less than 200*F.
Unit 1 Amendmertt-94 15.3.1-2 April 28,1985 Unit 2 Amendment 95 I
5.
Pressurizer Power-0perated Relief Valves (PORV) and PORV Block Valves a.
Two PORVs and their associated block valves shall be operable.
(1)
If a PORV is inoperable due to leakage in excess of that allowed in Specification 15.3.1.D, the PORV shall be restored to an operable condition within one hour or the associated block valve shall be closed.
l (2)
If a PORV is inoperable due to a channel functional test i
failure, the associated PORY control switch shall be placed and maintained in the closed position or the associated block valve shall be closed within one hour.
(3)
If a PORV block valve is int,perable, the ble'k solve shall be restored to an operable condition within one hour or the block valve shall be closed with power removed from the block valve; otherwise, the unit shall be in hot shutdown within the next six hours.
2 6.
The pressurizer shall be operable with at least 100 KW of pressurizer heaters available and a water level greater than 10% and less than 95%
during steady-state power operation. At least one bank of pressurizer heaters shall be supplied by an emergency bus power supply.
7.
Reactor Coolant Gas Vent System These Specifications are not applicable during cold or refueling shut-down conditions:
a.
At least one Reactor Coolant Gas Vent System vent path.to the pressurizer relief tank (PRT, or containment atmosphere shall be operable from each of the following locations:
(1) Reactor vessel head (2)
Pressurizer Each vent path from these locations to the common header includes two closed valves in parallel powered from emergency buses. The l
common header vents to the PRT and the containment atmosphere each contain a closed valve powered from an emergency bus which provides series isolation.
Unit 1 Amendment 93 15.3.1-3 August II, 1985 Unit 2 - Amendment 97
I b.
When unable to vent from the common header to the PRT or the contain-ment atmosphere, reactor startup and/or power operations may continue provided that the series isolation valve in the inoperable vent path is maintained closed with power removed from the valve actuator.
c.
If a vent path from the reactor vessel head or the pressurizer to the common header becomes inoperable, reactor startup and/or power opera-
~
tions may continue provided that the paralleled isolation valves in the inoperable vent path from that location to the common header are maintained closed with power removed from the valve actuator. This does not necessitate removing power from the PRT or containment atmosphere isolation valves. The inoperable vent path shall be restored to operable status within thirty days, or the reactor shall be placed in hot shutdown within six hours and in cold shutdown within the following thirty hours.
d.
If the vent paths from both the reactor vessel head and the pressurizer to the common header are inoperable or the vent paths from the common header to both the PRT and the containment atmosphere are j
inoperable, then maintain all the inoperable vent path valves closed with power removed from the valve actuators of all the valves in the inoperable vent paths.
Restore at least one of the vent paths from the reactor vessel head or pressurizer to the containment atmosphere or the PRT to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in hot shutdown within six hours and in cold shutdown within the following thirty
- hours, j
Basis When the boron concentration of the reactor coolant system is to be reduced, the i
process must be uniform to prevent sudden reactivity changes in the reactor.
0 Mixing of the reactor coolant will be sufficient to maintain a uniform boron concentration if at least one reactor coolant pump or one residual heat removal pump is running while the change is taking place. The residual heat removal pump will circulate the primary system volume in approximately one-half hour.
]
The pressurizer is of little concern because of the lower pressurizer volume and because pressurizer boron concentration normally will be higher than that of the rest of the reactor coolant.
Unit 1 - Amendment No. 93 15.3.1-3a August 11, 1985 Unit 2 - Amendment No. 97
Specification 15.3.1. A.1 requires that at least one reactor coolant pump must be operating whenever the average reactor coolant temperature is above 350*F unless the listed restrictions are established. This is required so that the FSAR zero power transients (rod withdrawal from subcritical and rod ejection) are addressed from conservative conditions. With the reactor subcritical, with required shutdown margin, and with the trip breakers open, a single rod ejection will not result in criticality being reached. With the reactor subcritical and the average reactor coolant temperature atove 350*F, a single reactor coolant pump provides sufficient decay heat removal capability. Heat transfer analyses") show that reactor heat equivalent to 3.5% of the rated power can be removed with natural circulation only.
}
i Items 15.3.1. A.I.a.(2) permits an orderly reduction in power if a reactor coolant pump is lost during operation between 3.5% and 50% of rated power.
Above 50% power, an automatic reactor trip will occur if either pump is lost.
The power-to-flow ratio will be maintained equal to or less than 1.0, which 1
ensures that the minimum DNB ratio increases at lower flow since the maximum l
enthalpy rise does not increase above its normal full-flow maximum value.")
l Specification 15.3.1.A.3 provides limiting conditions for operation to ensure that redundancy in decay heat removal methods is provided.
A single reactor coolant loop with its associated steam generator and a reactor cooltat pump or a single residual heat removal loop provides sufficient heat removal capacity for removing the reactor core decay heat; however, single failure considerations require that at least two decay heat removal methods be avail-able. Operability of a steam generator for decay heat removal includes two sources of water, water level indication in the steam generator, a vent path to atmosphere, and the Reactor Coolant System filled and vented so thermal convection cooling of the core is possible.
If the steam generators are not available for decay heat removal, this Specification requires both residual heat removal loops to be operable unless the reactor system is in the refueling shutdown condition with the refueling cavity flooded and no operations in progress which could cause an increase in reactor decay heat load or a decrease in boron concentration.
In this condition, the reactor vessel is essentially a fuel storage pool and removing a RHR loop from service provides conservative Unit 1 - Amendment No. 103 15.3.1-3b July 23, 1986 Unit 2 - Amendment No. 106 j
conditions should operability problems develop in the other RHR loop. Also, one residual heat removal loop may be temporarily out of service due to surveillance testing, calibration, or inspection requirements. The surveil-lance procedures follow administrative controls which allow for timely restoration of the residual heat removal loop to service if required.
6ddi;tibha;119dsith?Ead.tHF3661 int [ tim;iEFafuFsysts^6shl350 F23Hdll30Qll; U Efat.1hg;~dedaf hiat;}em6Va136 nip ~s](if thsMsidt3Dualihfjumiis[6Mi)Jd6sl P
hiat[Fimoyalyp; umps)TifeTi,ll okedi;t61tisTdsidsfyifsd 3f6FJa'3hbFi[t i;sieI([ h6Erf ki thithh3ti pulhtijonIthatl60rohJi10t id[sEffvli tTs@fsEsbtis1 Tuiisdish{ihit
^
cof;si 60t1;st[t6 nip'eFitUrifsmiin;30$6hl 6s]i;itLFif{6s'l The speratjon;fsfibns7eact6ric6olant pump]6FJ6ns1RHRydmpipr6videsisdsqhsti fl6W't.6f6nssfelisivi;6 @sventTstfatifiEat.ioniand[pf6dd#s)gE;addslifeIc~tljity 9
changesid6r(Wb6 r6;hTcoscentf afiinTridUdt 16n"s3FihEMsinthr@o61i6tisysfimy TheTreicti vi tEchinbe!'rifs fis soci alt;s;dTW1 thib6rbn'VidUcti onisil lf th"efs f6 Fey b6 Wi t h i ni theTaip;abi l. i ti? 6 f fope rstirf recogn i ti s#L ahd Tab 6t foli Each of the pressurizer safety valves is designed to relieve 288,000 lbs per hour of saturated steam at setpoint.
If no residual heat is removed by any of the means available, the amount of steam which could be generated at safety valve relief pressure would be less than half the valves' capacity.
One valve, therefore, provide adequate defense against overpressurization.
Below 350*F and 400 psig in the Reactor Coolant System, the residual heat removal system can remove decay heat and thereby control system temperature and pressure.
A PORV is defined as OPERABLE if leakage past the valve is less than that allowed in Specification 15.3.1.0 and the PORV has met its most recent channel test as specified in Table 15.4.1-1.
The PORVs operate to relieve, in a con-trolled manner, reactor coolant system pressure increases below the setting of the pressurizer safety valves. These PORVs have remotely operated block valves 1
i to provide a positive shutoff capability should a PORV become inoperable.
i Unu-l faendment-No-93 15.3.1-3c August 11, 1985 UnM 2 faendment-Hfh--97
1 The requirement that 100 KW of pressurizer heaters and their associated controls be capable of being supplied electrical power from an emergency bus provides assurance that these heaters can be energized during a loss of offsite power condition to maintain pressure control and natural circulation at hot shutdown.
l The requirement to have a reactor coolant system gas vent operable from the reactor vessel or the pressurizer steam space assures that non-condensible gases can be released from the Reactor Coolant System if necessary.
The Reactor Coolant Gas Vent System (RCGVS) provides an orificed vent path from s
the pressurizer steam space and an orificed vent path from the reactor vessel.
Both vent paths include two parallel solenoid-operated isolation valves which t
are powered from emergency buses and vent to a common header.
From the common header, ga es may be vented via separate lines, each with a single solenoid operated isolation valve powered from the emergency bus to the pressurizer relief tank or containment atmosphere. The orifice in these vent lines restricts leakage so that, in the event of a pipe break or isolation valve failure, makeup water for the leakage can be provided by a single coolant charging pump.
If a RCGVS vent path from either the pressurizer or reactor vessel head is inoperable, Specification 15.3.1. A.7.c requires the remotely
[
operable valves in that inoperable path to be shut with power removed.
If a j
vent path from the common header to the pressurizer relief tank or containment atmosphere is inoperable, the isolation valve in that path must be shut but reactor operations may continue.
If both vent paths to or both vent paths from the common header are inoperable, the RCGVS is inoperable and the steps in specification 15.3.1.A.7.d must be taken.
f i
FSAR Section 15.1.11.
l m
f FSAR Section 7.2.3.
)
Unit 1 - Amendment No. 103 15.3.1-3d July 23, 1986 Unit 2 - Amendment No. 106