ML20034F290

From kanterella
Jump to navigation Jump to search
Rev 1 to 1992 Semiannual Effluent Rept for Jan-June 1992
ML20034F290
Person / Time
Site: Prairie Island  
Issue date: 06/30/1992
From:
NORTHERN STATES POWER CO.
To:
Shared Package
ML20034F288 List:
References
NUDOCS 9303020562
Download: ML20034F290 (10)


Text

_._

1992 Effluent Semiannual Report REV. 1 Page 1 of 8 Retention: Lifetime 1

l EFFLUENT SEMIANNUAL REPORT

{

06-JAN-92 THROUGH 05-JUL-92 1

SUPPLEMENTAL INFORMATION

\\

l Facility:

Prairie Island Nuclear Generating Plant

)

i Licensee:

Northern States Power Company License Numbers: DPR-42 & DPR-60 i

i l

A.

Regulatory Limits l.

Liquid Effluents:

l a.

The dose or dose commitment to an individual from radioactive materials in liquid effluents released from the site shall be

]

limited to:

J l

for the quarter 3.0 mrem to the total body 10.0 mrem to any organ i

for the year 6.0 mrem to the total body 20.0 mrem to any organ 2.

Gaseous Effluents:

a.

The dose rate due to radioactive materials released in gaseous effluents from the site shall be limited to:

noble gases 4500 mrem / year total body 43000 mrem / year skin I-131, H-3, LLP (1500 mrem / year to any organ b.

The dose due to radioactive gaseous effluents shall be limited to:

noble gases 410 mrad / quarter gamma 420 mrad / quarter beta 420 mrad / year gamma 440 mrad / year beta I-131, H-3, LLP 415 mrem / quarter to any organ 430 mrem / year to any organ 9303020562 930226 PDR ADOCK 05000282 R

PDR

1992 EFFLUENT SEMIANNUAL REPORT REV. 1 PAGE 2 B.

Maximum Permissible Concentration l

1.

Fission and activation gases in gaseous releases:

l l

10 CFR 20, Appendix B, Table 2, Column 1 2.

Iodine and particulates with halflives greater than 8 days in gaseous releases:

10 CFR 20, Appendix B, Table 2, Column 1 3.

Liquid effluents for radionuclides other than dissolved or entrained gases:

l 10 CFR 20, Appendix B, Table 2, Column 2 l

l 4.

Liquid effluent dissolved and entrained gases:

2.0E-04 uCi/ml Total Activity l

C.

Average Energy Not applicable to Prairie Island regulatory limits.

l D.

Measurements and approximations of total activity i

1.

Fission and activation gases Total GeLi 25%

l in gaseous releases:

Nuclide GeLi 2.

Iodines in gaseous releases:

Total GeLi 125%

Nuclide GeLi 3.

Particulates in gaseous releases:

Total GeLi 125%

Nuclide GeLi 4.

Liquid effluents Total GeLi 25%

l Nuclide GeLi l

E.

Manual Revisions 1.

Offsite Dose Calculations Manual latest Revision number:

12 Revision date 30 JUN 91 2.

Process Control Program Manual latest Revision number:

4 Revision date 23-APR-91 I

I i

1992 EFFLUENT SEMIANNUAL REPORT REV. 1 PAGE 3 1.0 BATCH RELEASES (LIQUID)

QTR: 01 QTR: 02 1.1 NUMBER OF BATCH RELEASES 4.40E+01 1.60E+01 1.2 TOTAL TIME PERIOD (HRS) 6.67E+01 5.97E+01 1.3 MAXIMUM TIME PERIOD (HRS) 2.33E+00 7.75E+00 1.4 AVERAGE TIME PERIOD (HRS) 1.52E+00 3.73E+00

)

l 1.5 MINIMUM TIME PERIOD (HRS) 1.22E+00 1.17E+00 1.6 AVERAGE MISSISSIPPI RIVER FLOW (CFS) 1.42E+04 3.49E+04 I

l i

2.0 BATCH RELEASES (GASEOUS)

QTR: 01 QTR: 02 i

2.1 NUMBER OF BATCH RELEASES 1.80E+01 1.00E+00 f

2.2 TOTAL TIME PERIOD (HRS) 1.93E+02 2.20E+00 2.3 MAXIMUM TIME PERIOD (HRS) 2.40E+01 2.20E+00 2.4 AVERAGE TIME PERIOD (HRS) 1.07E+01 2.20E+00 2.5 MINIMUM TIME PERIOD (HRS) 3.30E-01 2.20E+00 i

3.0 ABNORMAL RELEASES (LIQUID)

QTR: 01 QTR: 02 3.1 NUMBER OF RELEASES 1.00E+00 0.00E+00 3.2 TOTAL ACTIVITY RELEASED (CI) 1.38E-03 0.00E+00 l

3.3 TOTAL TRITIUM RELEASED (CI) 9.46E-01 0.00E+00 4.0 ABNORMAL RELEASES (GASEOUS)

QTR: 01 QTR: 02 i

4.1 NUMBER OF RELEASES 0.00E+00 0.00E+00 4.2 TOTAL ACTIVITY RELEASED (CI) 0.00E+00 0.00E+00

l l

1992 EFFLUENT SEMIANNUAL REPORT REV. 1 PAGE 4 TABLE LA GKSEOUS EFFLUENTS - SUMMATION OF ALL RELEASES QTR: 01 QTR: 02 5.0 FISSION AND ACTIVATION GASES 5.1 TOTAL RELEASE (CI) 1.03E-01 4.40E+00 i

5.2 AVERAGE RELEASE RATE (UCI/SEC) 1.31E-02 5.60E-01

)

\\

5.3 GAMMA DOSE (MRAD) 1.52E-05 1.59E-03 l

l 5.4 BETA DOSE (MRAD) 2.25E-04 6.59E-03 5.5 PERCENT OF GAMMA TECH SPEC (%)

1.52E-04 1.59E-02 5.6 PERCENT OF BETA TECH SPEC (%)

1.13E-03 3.30E-02 6.0 IODINES 6.1 TOTAL I-131 (CI) 9.70E-07 0.00E+00 6.2 AVERAGE RELEASE RATE (UCI/SEC) 1.23E-07 0.00E+00 l

7.0 PARTICULATES 7.1 TOTAL RELEASE (CI) 2.67E-05 2.33E-05 7.2 AVERAGE RELEASE RATE (UCI/SEC) 3.39E-06 2.96E-06 8.0 TRITIUM 8.1 TOTAL RELEASE (CI) 8.22E+00 8.44E+00 8.2 AVERAGE RELEASE RATE (UCI/SEC) 1.05E+00 1.07E+00 9.0 TOTAL IODINE, PARTICULATE AND TRITIUM (UCI/SEC) 1.05E+00 1.07E+00 10.0 DOSE (MREM) 2.03E-02 1.52E-02 11.0 PERCENT OF TECH SPEC (%)

1.35E-01 1.01E-01 12.0 GROSS ALPHA (CI) 0.00E+00 0.00E+00 i

1992 EFFLUENT SEMIANNUAL REPORT REV. 1 PAGE 5 TABLE 1C GnSEOUS EFFLUENTS - GROUND LEVEL RELEASES 13.0 FISSION AND ACTIVATION GASES CONTINUOUS MODE BATCH MODE NUCLIDE UNITS QTR: 01 QTR: 02 QTR: 01 QTR: 02 KR-85 CI 8.87E-02 2.33E-01 XE-133 CI 7.51E-03 4.17E+00 7.25E-03 2.64E-04 1.40E-05 XE-135 CI TOTAL CI 9.62E-02 4.17E+00 7.26E-03 2.33E-01 l

i 14.0 IODINES CONTINUOUS MODE BATCH MODE NUCLIDE UNITS QTR: 01 QTR: 02 QTR: 01 QTR: 02 I-131 CI 9.70E-07 TOTAL CI 9.70E-07 0.00E+00 0.00E+00 0.00E+00 i

15.0 PARTICULATES CONTINUOUS MODE BATCH MODE NUCLIDE UNITS QTR: 01 QTR: 02 QTR: 01 QTR: 02 BR-82 CI 3.07E-06 6.72E-10 NB-97 CI 2.33E-05 SR-89 CI 5.26E-07 2.31E-05 TOTAL CI 3.60E-06 2.33E-05 2.31E-05 0.00E+00

1992 EFFLUENT SEMIANNUAL REPORT REV. 1 PAGE 6 TABLE 2A LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES QTR: 01 QTR: 02 16.0 VOLUME OF WASTE PRIOR TO DILUTION (LITERS) 4.21E+07 4.12E+07 17.0 VOLUME OF DILUTION WATER (LITERS) 1.57E+11 8.70E+10 18.0 FISSION AND ACTIVATION PRODUCTS 18.1 TOTAL RELEA6E W/O H-3, RADGAS, ALPHA (CI) 1.78E-01 1.50E-01 18.2 AVERAGE DILUTED CONCENTRATION (UCI/ML) 1.13E-09 1.72E-09 19.0 TRITIUM 19.1 TOTAL RELEASE (CI) 1.18E+02 1.05E+02 19.2 AVERAGE DILUTED CONCENTRATION (UCI/ML) 7.52E-07 1.21E-06 20.0 DISSOLVED AND ENTRAINED GASES 20.1 TOTAL RELEASE (CI) 1.90E-03 1.52E-03 20.2 AVERAGE DILUTED CONCENTRATION (UCI/ML) 1.21E-11 1.75E-11 21.0 GROSS ALPHA (CI) 0.00E+00 0.00E+00 22.0 TOTAL TRITIUM, FISSION AND ACTIVATION PRODUCTS (UCI/ML) 7.53E-07 1.21E-06 23.0 TOTAL BODY DOSE (MREM) 1.58E-03 4.63E-04 24.0 CRITICAL ORGAN 24.1 DOSE (MREM) 1.58E-03 1.86E-03 24.2 ORGAN TTL BODY GI TRACT 25.0 PERCENT OF TOTAL BODY TECH SPEC LIMIT (%)

5.27E-02 1.54E-02 26.0 PERCENT OF CRITICAL ORGAN TECH SPEC LIMIT (%)

5.27E-02 1.86E-02 1

l

r c

h l

\\

Subject:

Northern States Power, Prairie Island, Abnormal Liquid Release first quarter 1992 Normal radioactive liquid waste is released to the river through an underground eight and twelve inch cast iron pipe to the discharge canal.

The cast iron pipe connects to a twelve inch polypropylene pipe which extends to nea the sluice gates at the end of the discharge canal.

The radwaste discharge l

pipe was designed to transfer liquid radioactive waste from the auxiliary building to the discharge canal where it is combined with cooling tower blowdown water.

Tritium was detected in on-site test wells located southwest of the radwaste pipe.

Based on the anticipated groundwater flow direction, a hydrostatic test of the underground portion of the liquid radwaste discharge pipe was conducted on April 30, 1992.

This test showed the pipe to be leaking slightly.

Immediately after the hydro, the liquid waste discharge pipe was isolated and all subsequent radioactive releases were completed to the discharge canal via a temporary, above-ground l

discharge line.

Some accessible sections of the old discharge pipe were excavated and examined.

No leakage point was found.

Work is in progress to install a new underground discharge pipe.

Without confirming that a leak existed under release conditions, it is our assumption that a leak existed in l

some section of the pipe.

Given the normal discharge flow rate (less than 100 gpm) which results in the pipe being only partially filled, the release to the soil has l

been conservatively calculated at less than 0.5 gallons l

per minute.

The leak would have occurred in the l

unsaturated zone above the groundwater and flowed down until it is entrained in the groundwater.

All radionuclides except for tritium would have been removed soon after the liquid enters the soil.

Soil is an excellent filter for ionic molecules as well as particulate material.

No radionuclides other than tritium (and naturally-occurring uranium decay products) have been found in the test wells.

The released radioactivity would form a

plume in the groundwater.

This plume would have been diluted as it fanned f

out in the crossflow direction and as it moved in the direction of flow.

Radioactive decay also would serve to reduce the concentration.

Groundwater flow estimates indicated that a release may take from 10 to 70 years to l

l l

I

g.

Page 2 travel from the Mississippi River to the well distances in the direction of the vermillion River.

This would translate into significant dilution as well as decay for tritium which has a radioactive half-life of 12.3 years.

Sampling of surface and groundwater sources by the Radiological and Environmental Monitoring Program (REMP) identified some areas on site which may have been affected by the discharge pipe leak.

Sample results have shown tritium slightly higher than normal background levels.

Besides

tritium, no other isotopes other than normal background nuclides have been detected.

Test well P-10 showed the highest tritium concentrations at 1.5E-6 Ci/ml.

The most recent results are about 6.5E-07 pCi/ml.

The EPA drinking water limit is 2E-5 vCi/ml.

It is possible that the activity seen in P-10 is from past releases to the head of the discharge canal before we added the polypropylene extension to i

the discharge line.

For the semi-annual period of 06-Jan-92 to 05-Jul-92, there were 47 liquid waste discharges up until 30-Apr-92.

The duration of these releases totaled 71.45 hours5.208333e-4 days <br />0.0125 hours <br />7.440476e-5 weeks <br />1.71225e-5 months <br />.

Assuming the leak existed throughout the entire reporting period at the conservative leak rate of 0.5 gpm, a total volume of 8.12E+06 mis would have been released to the soil in the area surrounding the leak. Using the concentration and nuclide mix of the waste tanks released during the period, a

total activity (excluding tritium) of 1.38E+03 Ci and 9.46E+05 pci of tritium would have been released.

This activity has been reported as a single abnormal release in the first quarter of the semi-annual report.

I i

i l

1992 EFFLUENT SEMIANNUAL REPORT REV. 1 PAGE 7 TABLE 2A LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES 27.0 INDIVIDUAL LIQUID EFFLUENT 1

CONTINUOUS MODE BATCH MODE NUCLIDE UNITS QTR: 01 QTR: 02 QTR: 01 QTR: 02 i

AG-110M CI 1.68E-02 1.32E-02 i

BE-7 CI 1.15E-03 4.14E-05 1

CO-57 CI 6.88E-05 1.10E-04 CO-58 CI 2.82E-02 3.18E-02 CO-60 CI 1.19E-02 6.62E-03 CR-51 CI 6.44E-03 9.85E-04 CS-134 CI 6.54E-06 3.44E-06 CS-137 CI 2.20E-04 CU-64 CI 1.56E-03 FE-55 CI 2.26E-03 2.55E-02 7.62E-02 6.10E-02

)

FE-59 CI 6.63E-03 1.55E-03 I-133 CI 4.81E-06 l

I-134 CI 4.97E-06 LA-140 CI 7.04E-06 MN-54 CI 7.34E-04 3.02E-04 NA-24 CI 1.71E-05 NB-95 CI 1.45E-04 2.00E-05 NB-97 CI 6.37E-06 RH-105 CI 3.32E-05 SB-122 CI 2.51E-03 SB-124 CI 1.29E-02 4.74E-03 SB-125 CI 1.03E-02 4.75E-03 SB-126 CI 6.25E-05 CONTINUED

1992 EFFLUENT SEMIANNUAL REPORT REV. 1 PAGE 8 TA'BLE 2A LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES l

27.0 INDIVIDUAL LIQUID EFFLUENT (CONTINUED) i SC-47 CI 4.28E-04 1.29E-05 l

SN-113 CI 1.30E-03 5.67E-04 SR-92 CI 1.22E-05 W-187 CI 1.58E-05 4.78E-06 Y-93 CI 3.42E-05 ZN-65 CI 1.53E-05 ZR-95 CI 1.65E-04 8.65E-05

\\

l ZR-97 CI 3.88E-06 i

TOTAL CI 2.26E-03 2.55E-02 1.76E-01 1.24E-01 l

28.0 DISSOLVED AND ENTRAINED GASES i

i CONTINUOUS MODE BATCH MODE NUCLIDE UNITS QTR: 01 QTR: 02 QTR: 01 QTR: 02 XE-133 CI 1.88E-03 1.52E-03 XE-135 CI 2.15E-05 TOTAL CI 0.00E+00 0.00E+00 1.90E-03 1.52E-03 l

l

_