ML20031F069

From kanterella
Jump to navigation Jump to search
Requests 2-month Extension to Respond to Request for Technical Assistance Re Review of Westinghouse Preliminary Evaluation of Steam Generator Tube Denting Phenomenon Rept
ML20031F069
Person / Time
Issue date: 05/04/1976
From: Shao L
Office of Nuclear Reactor Regulation
To: Ross W
Office of Nuclear Reactor Regulation
Shared Package
ML13319A640 List: ... further results
References
FOIA-81-313 NUDOCS 8110190125
Download: ML20031F069 (1)


Text

'

t-

8 1

UNIT [D f.s ATES

[,

1 NUCLEAH REGULATORY COMMISSION g,tf.);riv)(, j wAsmoron. o. c. 20sss w.1 g,..vQ' /

y MAY 0 41976

. >. =

e William J. Ross Operating Reactors Branch #4 Division of Operating Reactors TECHNICAL ASSISTANCE REQUEST NO. ORB-4-39 Generic Concern:

Potential Mechanical Damage, " Denting", to Steam Generator Tubing at Operating PWR Plants The Engineering Branch, Division of Operating Ret.ctors has reviewed the Westinghouse " Preliminary Evaluation of the Steam Generator Tube l

Denting Phenomenon Report" dated December 1975.

We find the report i

incomplete and we have discussed specific areas with Westinghouse.

Westinghouse has agreed to address our areas of concern in the report and they have committed to supply us with additional test data by May 10, 1976.

In order to evaluate the additional test results from Westinghouse, we request an extension, at least two months, for our response to l

your TAR No. ORB-4-39.

l s.A.o L. C. Shao, Chief Engineering Branch Division of Operating Reactors cc:

V. Stello, DOR D. G. Eisenhut, DOR I

l K. R. Goller, DOR R. R. Maccary, DSS i

-l R. W. Reid, DOR M. Fairtile, DOR W. S. Hazelton, DOR i

R. J. Stuart, DOR i

B. D. Liaw, DOR l

l F. M. Almeter, DOR l

r i

t i

p 08110190125 810827 f"PDR FOIA UDE1.L81-313 PDR<

~r

,-,.,.=,,c---.

- - - -