05000369/LER-1981-137-03, /03L-0:on 810810,train B of Control Room Area Ventilation Sys Failed to Start & Declared Inoperable.Cause Unknown.Maint Completed Checkout of Sys Oil Levels & Pressures

From kanterella
(Redirected from ML20010G959)
Jump to navigation Jump to search
/03L-0:on 810810,train B of Control Room Area Ventilation Sys Failed to Start & Declared Inoperable.Cause Unknown.Maint Completed Checkout of Sys Oil Levels & Pressures
ML20010G959
Person / Time
Site: McGuire 
Issue date: 09/09/1981
From: Nardoci P
DUKE POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20010G954 List:
References
LER-81-137-03L, LER-81-137-3L, NUDOCS 8109220714
Download: ML20010G959 (1)


LER-1981-137, /03L-0:on 810810,train B of Control Room Area Ventilation Sys Failed to Start & Declared Inoperable.Cause Unknown.Maint Completed Checkout of Sys Oil Levels & Pressures
Event date:
Report date:
3691981137R03 - NRC Website

text

., bh.~

weeC FCA40 34 U.3.NUCLEAA aEcutATOnv Oceaneissacae Q '73 tJCENSEE EVENT REPCAT EXHIBIT A c:aTwet aLocx: I 1

l I I e@

tetaAss PatwT on Tvet att mEcumso pescauricasi i

is lil lN i C; MjG lS j 1 0l q -l 0[ 0l 0 l 0; 0l -l 0 1 O g 4l1llj 1[ Ig l Jg e e usaueceoe i.

s wcansa w-eam a

s uce.sa rves.a uw4
Cn=

laiti M lL @l 01 5101 Of 0131 6! 9 @l 01811101811 @l 0191019181 I f@

r a

m

.ac,,,,,

avtarsars rs aepear are 4.

EVENT OE$cAtmCN AMC pgCS A4L1 OCNSECUENCES Q 1 a 2 ! IWhile in Mode 2, Train "B" of the control room area ventilation system failed ;

,,,,,,to start. Train "B" was declared inoperable and an action statement initiated i o.. i I per T.S.3.7.6 which is reportable pursuant to T.S. 6.9.1.13(b). Since the re-9 g,,,,dundant Train "A" of the control room area ventilation system was available and

,2.,,

loperating during the time Train "B" would not start, r*..e health and safety of

,,,,,gthe public were not affected.

i24 t

I syTTtte

4use CALss
aea
watv, c :e

=os n.ac ce e

laise i S ; Gl@ gg l Zlg [Z l y-l Zl y l Z Q g g g.se:::g stecces n

?

4 s

24 ts 12 t2 s

as

Q

$.4.C,ggarvtag m getMct a gvassom.

as pc.s,ey

...,.a ear-s4 car e we.

w

,,a OJag, i 8f1 I l-l

! 11 31 71 1/l 1013 l IL l g

6 L2 a

=

a 27 s

=

a 2.

u

a l m

= a :-

n'= T.m r.:N.. r'=rgg lYlglZ l 9 l 9 9 gig r

a,=::,,

lX g [Z_fg l zig l,J @

(0 ;0 ! 0l-Ul l] g l

u

Ausa cescsimca Ano ecamsenvs Ac :c es @

4,,a,lThere is no apparent reason why train "B" would not start. After the system

,,,, failed to start, the preoperational checkout was verified, but it still failed,

,,,,,jto start. After checking the oil levels on the system and finding them suffi

,cient, another attempt to start was made which was successful, even though no,

,,; corrective action had been taken. Maintenance completed a checkout of the systpm

?

s e oil levels and pressures and und everything in order.

as

'sYT stSCOW97.Y 343Cp6pMCm @

fus s po.sem cTieeR f7ATUS

  • N Y

l1 !SI W h lOI OIO!hl Mode 2

I W@l Personnel observation I

t ag y

is is a.

as

.e so assou=7os.c tyvTv h l t.ocaTiose ca neLaAss h

.eLaAssa s.vtsass l i t o l Q,j 11Ql N/A l N/A I

l,1 o,e.'.o a

I i # 71 101 0 l 0@y@[ scmepftcah asunseep net

=e N/A l

O

'.uu2 a a

i,l,;[OU'j"Ogl*"*""*"

N/A l

7 se is 12 se esed h

d (,3_j @ l N/A l

r a e io so

"O7,',',,,,,,,, @

Nac use enLy 121st b.,61 N/A l

ll tI

i
ir l

l l

Ne.ansesenspAnsa Phillin B.

Nardoci p,.cu s. ( 7 nta q 71._7f, q 9 8109220714 810909 PDR ADOCK 05000369 S