05000302/LER-1981-054-03, /03L-0:on 810806,over Past Several Yrs,Various Hydraulic Snubbers Had Been Repaired for Causes Not Attributable to Specific Shutdown Activity.Caused by Cracked Aluminum Bushings.Bushings Replaced

From kanterella
(Redirected from ML20010F811)
Jump to navigation Jump to search
/03L-0:on 810806,over Past Several Yrs,Various Hydraulic Snubbers Had Been Repaired for Causes Not Attributable to Specific Shutdown Activity.Caused by Cracked Aluminum Bushings.Bushings Replaced
ML20010F811
Person / Time
Site: Crystal River 
Issue date: 09/04/1981
From: Hernandz V
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20010F807 List:
References
LER-81-054-03L, LER-81-54-3L, NUDOCS 8109110364
Download: ML20010F811 (2)


LER-1981-054, /03L-0:on 810806,over Past Several Yrs,Various Hydraulic Snubbers Had Been Repaired for Causes Not Attributable to Specific Shutdown Activity.Caused by Cracked Aluminum Bushings.Bushings Replaced
Event date:
Report date:
3021981054R03 - NRC Website

text

(7 77)

LICENSEE EVENT REPORT

' hot 4TRUL BLOCX: !

l l

l l

l l

(PLE ASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

j o l t l l F l L l C l R l P l 3 jgl 0 l0 l-j.0 l0 l0 l0 l0 l -l 0l0 lgl 4l 1l 1l 1l 1l@l l

lg 1

8 9 LICENSEE CODE 14 15 LICENSE NUMBER 26 26 LICENSE TYPE 40 57 CAT 68 l

t 3[RC lLl@] q 5 l 0 l - l 0 l 3 l 0 12 @l n l 9 l n l r I e l, l@l0 19 10 I4 I 8 l1 l@

7 8

60 61 DOCKET NUVBER 68 69 EVENT DATE 71 75 REPORT DATE 80 l

EVENT DESCRIPTION AND PROBABLE CONSEQUENCES h l

10121 l At 0930 during normal operation, it was discovered that during shutdown maintenance I

activities over the past several years, various hydraulic snubbers had been repaired l

,g,3, g

for causes not attributed to specific shutdown activity and, therefore, are reportable l

,g,,,

g

, as contrary to T.S.3.7.9.1.

There seas no effect upon the health or safety of the l

g,

l 0 lG l l is the fifth event reported under this Specification.

l gg,,,

g 10181 l 80 SYSTEM

CAUSE

CAUSE COMP.

VALVE CODE CODE SUBCODE COv80NENT CODE SUBCODE SU8 CODE loisi IZ IZ l@ W@ l c l@ l si el vi al al r1@ W@ U @

7 8

9 10 11 12 13 14 is 20 SE QUE NTI AL OCCURRENCE REPORT REVISION

,_ EVENT YE AR REPORT NO.

CODE TYPE N O.

@;LERRO l218111 l-l l o I s 14 I Lc]

Inl3I W

I-l Lal g,g 22 23 24 26 27 28 29 30 31 32 TA EN A C

ON PL NT VE HOURS SB IT FOR B.

SUPPLIER MAN FACT RER I of of ol ol LrJ@

W@

W@

l_el,li 17 l@

f' l Al@l x l@

lZl@

l'l@

33 34 35 36 J/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS l 1 { 0 l l The cause of this event is attributed en c rn ckca n 1 n-f rm-bushines in the nnnhhorn.

I

,,,l The bushings were replaced with stainless steel bushings. An Engineerine Investication!

3 g (REI 80-12-11) is being condue.ted to investigate snubber failures. Approximate 1v 25%

l

,,7 of Containment Building snubber bushings vill be replaced during the next refueling.

I g

All accessible snubbers have been inspected.

l g

7 8 9 STA 5

% POWER OTHER STATUS IS O RY DISCOVERY DESCRIPTION 1

l1 l 5 l l El@ l 1 l 0 l 0 l@l N/A l

1Bl@l Encineer Observation ACTIVITY CC TENT LOCATION OF RELE ASE RELEASEC OF FELE ASE AYOUNT OF ACTIVITY l

lil6j l Zl @ l Z l@l N/A I

I N/A E X POSN ES PEPSO M E NUVEEP TYPE

DESCRIPTION

I lil71 l olo d @WS

- is PwSO.. d',mu'R,ES oESCRiPriON@

1 Nu..s g li 181 I ol ol ol@l yn 7

8 9 11 12 LOSS OF CR D A'.' AGE TO F ACILITY TYPE

DESCRIPTION

N/

~

l l_Zj@l ~

N/A LIPTiO,@

Soflo8Sfo$o8$o2 NRc USe ONLv S

PDR l

j llll;;;;;jly

, sue @l un 2 o 7

8 9 10 j* ((MW hg-,

68 69 80 5 904/795-6486 o

PHONE:

NA*'E OF PREPARER GNURPMqHED SUPPLEMENTARY IWORMATION SHEET)

L

f. -

SUPPLEMENTARY INFORMATION REPORT:

  1. 50-302/81-054/03L-0 FACILITY: Crystal River Unit 3 REPORT DATE: September 4,1981 Occurrence: August 6,1981 IDENTIFICATION OF OCCURRENCE:

Various hydraulic snubbers were discovered to have been inoperable during shutdown maintenance activities conducted over the past several years.

This created events not attributed to specific shutdown activities as required by Regulatory Guide 1.16 and, therefore, is reportable as being contrary to Technical Specification 3.7.9.1.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 1 Power Operation (100%).

DESCRIPTION OF OCCURRENCE:

At 0930, during normal operation, it was discovered that during shut-down maintenance activities over the past sever 2.

years, various hydraulic snubbers had been repaired as follows:

Five snubbers have been found with cracked bushings and ware subsequently found inoperable:

RCH-63, RCH-69, RCH-90 all found during July, 1979 Inspection RCH-70 was found during March,1980 Inspection RCH-74 was found during March, 1981 Inspection DESIGNATION OF APPARENT CAUSE:

The cause of this event is attributed to cracked altininum bushings in the power piping snubbers.

An engineering investigation (REI 80 11) is being conducted to investigate snubber failures.

ANALYSIS OF OCCURRENCE:

There was no effect upon the health er safety of the general public.

CORRECTIVE ACTION

The bushings were replaced with stainless steel bushings.

Approxi-mately 25 percent of Containment Building snubbers bushings will be replaced during the Refueling Outage.

All accessible snubbers have been inspected.

FAILURE DATA:

There were five snubbers discovered to have been inoperable,and this is the fifth event reported under this Specification.