ML20010A648

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violation Noted in IE Insp Rept 50-302/81-07.Corrective Actions:Procedural & Surveillance Testing Program Changes Made.Personnel Retrained
ML20010A648
Person / Time
Site: Crystal River 
Issue date: 07/15/1981
From: Baynard P
FLORIDA POWER CORP.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20010A647 List:
References
CS-81-157, NUDOCS 8108110633
Download: ML20010A648 (3)


Text

--.

oco i

' v ;;: 0 p : q -

o a

e o

eOQ :.G a

~

s eo see

. I.! t ' P0 23 40 j

Floricia July 15,1981 MT 3-0-3-a-2 c "'""'*

CS-81-157

  1. 3-071 -20 Mr. J. P. O'Reilly, Director Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission 101 Marietta St., Suite 3100 Atlanta, GA 30303

Subject:

b

'.et No. 50-302 License No. DPR-72

Reference:

RII:TFS 50-302/81-07

Dear Mr. O'Reilly:

We offer the following response to the violation listed in the referenced inspection report.

NOTICE OF VIOLATION Technical Specification 3.7.8.1 requires the auxiliary building ventilation exhaust system to be operable with four filter systems. The action state-ment for Technical Specification 3.7.8.1 allows continued operation for up to seven days with one filter system inoperable.

Contrary to the above, during the period of 1200 hours0.0139 days <br />0.333 hours <br />0.00198 weeks <br />4.566e-4 months <br /> on May 5, 1981 through 1554 hours0.018 days <br />0.432 hours <br />0.00257 weeks <br />5.91297e-4 months <br /> on May 9, 1981 power operations continued with three of the four required filter systems inoperable due to maintenance activities being conducted on the filter system.

Response: Florida Power Corporation concurs with the vio?.ation,and we offer the following:

-We find the reason for violation was the lack of complete under-standing of Technical Specification 3.7.8.1 by personnel involved with testing the filter system while in Mode 1.

The Surveillance Procedure and the Maintenance Procedure did not contain any caution notes to warn personnel of the ramifications for multiple filter removal. Procedure changes have been made to rectify this. 'SP-187, Auxiliary Building Ventilation Exhaust System Testing, and MP-106, HEPA and Charcoal Filter Removal and Replacement,were both amended on 6/2/81.

8108110633 810804

?,

05000302)l PDR ADOCK G

PDR General Offic'e 3201 Tnirty-fourtn stre-t soutn. P O Box 14042 St Petersburg, Florida 33733 e 813-866-5151

r_

+

  • *~

Notice'of Violation Responne Ref: RII:TFS 50-302/81-07 Page 2

-On May 15, 1981, the Technical Specifications Coordinator conducted training for all Technical Services Engineers on Technical Specifica-tion requirements with respect to LIMITING CONDITIONS FOR OPERA 110N and SURVEILLANCE REQUIREMENTS. As a result of the instruction and procedure changes, we have administrative 1y altered our surveillance testing program; wherein, only one filter will be tested at a time.

In addition to this, "e have been seeking relief from STS 3.7.8.1 for filter testing.

Furthermorc, a Request for Engineering Information has been generated that would install a new refueling area filter system separate from the Auxillary Building filter system and thus relax the Limiting Cenditions for Operation for this Specification.

We are, at this time, in full compliance wit:i this Specification.

Should there be further questions, please contact us.

Very truly yours, FLORIDA POWER CORPORATION k.' B ard Nuclear Plant Manager lianager -

Nuclear Support iServices JC/rc t

l I

~

r r

STATE OF FLORIDA COUNTY OF PINELLAS 1

P.

Y.

Baynard states that she is the Manager, Nuclear Support Services, of Florida Power Corporation; that she is authorized on i

the part of said cornany to sign and file with the Nuclear Regulatory Comission. the information attached hereto; and that all such - statements made and matters set forth therein are true and correct to the best of his knowleQe, information, and belief.

TW u-c2<n,as d -

~

l P()T. Bayyard Subscribed and sworn to before me, c Notary Public in and for the Stute and County above named, this 14th day of July,1981.

t4%4>

y Notary Public Notary Public, State of Florida at Large, My Comission Expires:

May 29,1984 P

,,,.1-,.-#

-.w..,

m,e c,,es.,,