t DDQqC

$\\G ex

(,p

~Q

't -

4-o-

c, O

y M\\%

M O\\6 June 19, 1981 p

f k

6 Docket Nos. 50-266 f

. h_

and 50-301 O

Nf 8,

u,,, l 2 5 98k @,

FACILITY: Point Beach Nuclear Plant Units 1 + 2 1,,

LICENSEE: Wisconsin Electric Power Company 4

m

SUBJECT:

TRIP REPORT - Point Beach Masonry Wall Site Audit and Annual Plant Visit on June 8 - 12, 1981.

On June 8, 1981. Timothy G. Colburn, Point Beach Project Manager accompanied David Jeng, Nilesh Chokski and K.C. Leu from the Structural Engineering Branch and Howard Wong from IE Headquarters on a site audit and visit of the Point Beach Nuclear Plant. This audit was arranged at the request of the Structural Engineering Branch to help resolve the Masonry Wall Issue which was the subject of IE Bulletin 80-11.

(MP-B-59) thelicensee).

A conference call with Wisconsin Electric Power Company (m(asonry and Point Beach, Bechtel, (architect consultant) Computech Structural consultant) and the NRC staff was held prior to the visit to arrange for the availability of records and documentation needed during the review. The plans and purpose of the visit were discussed with the resident inspector. The audit started with a walk down inspection of the rste than 50 masonry walls in question. Bechtel and Computach then presented their design concepts, assumptions and calculations which formed the basis of their previous submittals. The next two days were spent discussing differencas between the Point Beach proposals and the NRC staff position, reviewing detailed calculations and data, and formulating a list of action items necessary to resolve the NRC staff's concerns.

A closing conference was held to discuss the proposed action iteas and:

~

their scheduling, both parties acknowledging that these items were subject to management approval. A list of attendees is attached.

This visit was extremely helpful in many ways.

(1) It allowed a first hand view of the existing structures at Point Beach - necessary in understanding the assumptions used in their previous submittals.

(2) It allowed for face-to-face contact and detailed data review -

necessary in understanding the development of the licensee's design criteria.

(3) It accomplished much more in a shorter period of time than could have been accomplished using conference calls and additional 8107070049 eiofg Ntion requests.

PDR ADOCK 05000 P

P DATEk unc ronu m oo,eoi nacu o24o OFFICIAL RECORD COPY w-2n24,

e,

,wm

%q;f

=

y

(

, I think a similar approach to the problem will help other project manager's solve this issue expeditiously.

While at the Point Beach plant, the project manager was able to discuss technical issues with the plant staff including the licensee's February 4,1981 Technical Specification change request and the content of inadvertent boron dilution training for control room operators. Operating philosophy was discussed with the plant superintendent.

In addition to helping resolve the Masonry Wall issue, this visit served as the annual site visit for the project manager allowing him to maintain familiarity with plant facilities and equipmaits and converse with various members of the plant staff and the Resident Inspector.

Original sigrwxt y T. G. Colburn Project Manager Operating Reactors Branch f3 Division of Licersing

Enclosure:

As stated cc: See next page

,k, om=> 0.RB 0RBf3 pl.

0

,,c

~ ~a 4...s... u,, z e r., Jcs.1

. /,ep,, R.

,,t,,,,,,,,

i

" " " > 6/./.9/.e.1........ 6/l.4/.81..... 6/.dI.81,,,,,,,

CdRC FORM 318110/8C, N RC' l O240 OFFICIAL RECORD COPY

  • " 'we % 32 u 24

,r.

1..

Wisconsin Electric Pctier Ccepany s e s t +.* C C

.. u,. +....,...r..,

e..,

u..

+ z..

,, c.... s.

sug ie, ec. a

.v.o...ouv..c s..:..

oi..,.

n, c

Cocket File i:R: PDR

,et,

...n,.

v I' nn F. r e. 0;... r s,.

.s.y

m. i.,,,.,.*., e.s.

s.. c.. t c...., r. r.,

a -

iu BGrices

..l ar.r.

Project Manager Licensing Assistant ACRE (10)

Mtg Su=ary Dist.

?!P.C Participants b

Wisconsin Electric Power Company cc:

Mr. Bruce Churchill, Esquire Mr. William Guldemond Shaw, Pittman, Potts and Trowbridge USNRC Resident Inspectors Office 1800 M Street, N. W.

6612 Nuclear Road Washington, D. C.

20036 Two Rivers, Wisconsin 54241 Joseph Mann Library 1516 Sixteenth Street Two Rivers, Wisconsin 54241 Mr. Glenn A. Reed, Manager Nuclear Operations Wisconsin Electric Power Company Point Beach Nuclear Plant 6610 Nuclear Road Two Rivers, Wisconsin 54241 Mr. Gordon Blaha Town Chairraan Town of Two Creeks Route 3 Two Rivers, Wisconsin 54241 Ms. Kathleen M. Falk General Counsel Wisconsin's Environmental Decade 302 E. Washington Avenue Madison, Wisconsin 53703 Director, Criteria and Standards Division Office of Radiation Programs (ANR-460)

U.S. Environmental Protection Agency Washington, D. C.

20460

~

U. S. Environmental Protection Agency Federal Activities Branch Region V Office ATTN: EIS C0ORDINATOR 230 S. Dearborn Street Chicago, Illinois 60604 cc w/ enclosure (s) and incoming dtd:

Chai rman Public Service Commission of Wisconsin Hills Farns State Office Building Madison, Wisconsin 53702

Ilb V3 WI C LIST OF ATTENDEES NRC WEPC0 Tim Colburn Glenn Reed Chuck Krause David Jeng Howard Wong Art Reimer Nib:h Chokshi Dave Zabransky K. C. Lev BECHTEL COMPUTECH Andy Matyas Ron Mayes Jye-Ming Liu t-

- - - -_- _ __-___