05000336/LER-1981-015-03, /03L-0:on 810402,outboard End Packing Showed Signs of Failure During Operability Testing of Turbine Driven Auxiliary Feedwater Pump.Caused by Packing Nearing Natural End of Life.Packing Gland Loosened & Packing Flushed

From kanterella
(Redirected from ML20003H346)
Jump to navigation Jump to search
/03L-0:on 810402,outboard End Packing Showed Signs of Failure During Operability Testing of Turbine Driven Auxiliary Feedwater Pump.Caused by Packing Nearing Natural End of Life.Packing Gland Loosened & Packing Flushed
ML20003H346
Person / Time
Site: Millstone 
Issue date: 05/01/1981
From: Blanchard R
NORTHEAST NUCLEAR ENERGY CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20003H344 List:
References
LER-81-015-03L-01, LER-81-15-3L-1, NUDOCS 8105050618
Download: ML20003H346 (1)


LER-1981-015, /03L-0:on 810402,outboard End Packing Showed Signs of Failure During Operability Testing of Turbine Driven Auxiliary Feedwater Pump.Caused by Packing Nearing Natural End of Life.Packing Gland Loosened & Packing Flushed
Event date:
Report date:
3361981015R03 - NRC Website

text

....

[

(NE A'.E I.It T CR ThPE ALL nEQU nED tJ Fort'* cts c'%;*.1848,it il CCP*

k..

3 GJ !c J TjnjN Jsj 2 Jg oj_oj -j o j o j_o j ojoj-Jo g j@L4 L 2h

?G t actt.st t y t t JO 57 CAT *a tsCENst Nur. ::LR 14 5

9 l.8f I M E E f.00E

~

l@

F (D"= LLj@lo l s Io lo_ Loll 313 I 6 J@l0J410 l_2l 811 j@Lo i s l_

oN T 80 C8 09 (VENT DATE 74 75 nEPORT DATE oTr1 OOCnET taur. uER 60 61 EVENT DESCRIPTION AND FROBA8tt.coZCOUENCES h 8

feedwater p_ ump _

1 During routine operability testing of the turbine driven auxiliary _

3 Til l_

Thus three auxiliary feedwater j

the outboard end packing showed signs of failure.

pumps were not operable as required by Technical Specification gL g;

i tion

[..

of the remaining two pumps was verified in accordance with Technical Spe j,g3, g Total time pump was out of service -

]

4.7.1.2 and plant operation continued.

4 g g;i j

1.s hours. 'Similar events LER 81-14 (4/16/81) g,q g 1

80 EDO I sVr C7/dE se'YsE

' SM"

'c^OiM

  1. 3sE CO.,PO~E~T CODE I c I H ]@ [E_J@ [2Fj @ IP l Ul Ml P I X l X j@ [_8J@ L C

20 18 19 REVISION o s 1

13 OCCURRENCE REFORT 9

to 13 NO.

7 8

SE QUE NTI At.

CODE TYPE

.@,a(j,'gjpg18111 l-j l o i l l's J [gj LoisJ LLJ L-J LoJ REPORT NO:

_. EVENT YE AR g

21 22 23 24 26 27 28 29 30 31 32

.=

MAN FA TURER HOURS 22 S B IT F

8.

5 PPLI lEJg[34A j g [35Z Jg [36Zj@

l 0 l010 l0 l

[ f]J@

[]j@

[ A J@

l1 10 l7 l s j@

K N A TC O PLANT ET 47 44 33_

37 40 41 42 43 CAUSE DESCalPTION AND CORRECTIVE ACTIONS h Packing is approximately five years old.

]

Nearing the natural end of packing life.

iO l Pump operability was J

Packing gland was loosened, packing flushed and readjusted.

Preventive Maintenance j verified in accordance with Technical Specification 4.7.1.2.

J

,, l schedule modified to replace packing at three year intervals. Initial replac l, 3 l j

will be done'as soon as packing is available, 80 i,,, ; ;

DISCOVERY DESCRIPTION Operator Observation J

i 8 9 OMR STATUS j Or hRY@l

% PO R 5b@ l l I l0jgl LOCATION OF RELEASE @

'5 t s J

@j A!TeviTY cO iENT AuOuuT Or ACrivirv l

NA r.etE AssO Cr RELE AsE l

NA li Is j [Z_J @ [Z_J@MEs

_J P:Rson~Et expos NUuS E R TYPE

DESCRIPTION

NA -

li l71 l0 l0 l Oj@[Z J@l J

ERsO~~Etiu2vk'itsDEscRwiiOs@

80 Nuv8tR NA li la l l0 l0 l Ol@l J

7 8 9 11 12 0

T PE DEsCR PT ON NA [Nj@l

" "' "S' i

2 9 810 5 0 5 0 (p /F

_j ((l11IIIIIil]

8 9

,0 I2lel @i @ EE7CR,,,0~ @

80" is NA J8 69 l

507

[

anchard. Jr-Psone M,,_MZ-1791 Fxt I

8 9 to