Responds to NRC Re Violations Noted in IE Insp Repts 50-269/80-39,50-270/80-34 & 50-287/80-30.Corrective Actions:Reinspected Ref Welds Using Proper Calibr & Cautioned All B&W Inspectors to Document Calibr & Insps
ML19350C024
Person / Time
Site: Oconee  
Issue date: 03/06/1981
From: Parker W
DUKE POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19350C022 List:
References
NUDOCS 8103240712
Download: ML19350C024 (3)


Text

I

,e c

=

O DUKE POWER COMPAN Powra Dust.nixo 422 SouTa Cauncu SrazzT, CzuntoTTz, N. C. asa4a

,\\

WI L LI AM O. PA R M ER, J R.

Tetgewows:Anta 704 VH:t PatsiotNT March 6, 1981 32 3..o.3 sec. e oouctie.

i Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303 Re: RII:NE 50-269/80-39 50-270/80-34 50-287/80-30

Dear Sir:

With regard to C. E. Murphy's letter of February 10, 1981 which transmitted the subject inspection report, Duke Power Company does not consider the information contained therein to be proprietary.

Please find attached a response to the cited item of noncompliance.

Ver truly yours,

/

~s William O. Parker, Jr.

JLJ:pw Attachment

'B'1 0 3 2 4 0 4

4 Mr. James P. O'Reilly, Director March 6, 1981 Page Two WILLIAM 0. PARKER, JR., being duly sworn, states that he is Vice President of Duke Power Company; that he is authorized on the part of said Company to sign and file with the Nuclear Regulatory Commission this response to IE Inspection Report 50-269/80-39, 50-270/80-34, 50-287/80-30 with respect to Ocenee Nuclear Station; and that all statements and mattere set forth the in are true ando:orrect to the best of his knowledge.

6@

William O. Parker, Jr., VQresident Subscribed and sworn to before me this 6th day of March, 1981 L C. aU A Notary Public

~

i My Commission Expires:

September 20, 1984 t

t

DUKE POWER COMPANY OCONEE NUCLEAR STATION Response to I.E. Inspection Report 50-269/80-39, -270/80-34, -287/80-30 Violation 10 CFR 50, Appendix B, Criterion V as implemented by Topical Report Duke-1-A, Section 17, paragraph 17.1.5 requires in part that activities affecting quality shall be accomplished in accordance with the requirements Laposed by instructions procedures.and drawings. Paragraph 8 of procedure ISI-120 Re-vision 10, requires UT instruments to be calibrated on circumferential and axial holes of the calibration.. block. Also, that pipe welds be scanned in the circumferential and axial directions and the results documented accordingly.

Contrary to the above, activities affecting quality were not being accomplished in accordance with procedures in that examination records for pipe welds B4.5.71, B4.5.72 and B4.7.53 made no reference to axial or circumferential calibrations and weld examinations performed.

This is a Severity Level V Violation (Supplement I.E.).

Response

As stated in the above, a violation did result due to personnel error.ht that Procedure ISI-120 Revision 10 was not followed properly by the Babcock &1 Wilcox inspectors. The welds referenced in the above violation, figure numbers B4.5.71, B4.5.72,-and B4.5.73, were reinspected using-the proper calibration techniques on January 13, 1981.

Documentation for all other UT inspections

. performed prior to this data was reviewed to assure that the proper calibrations and scans had been performed. All Babcock & Wilcox inspectors at Oconee were cautioned to document all calibrations and inspections as required in Procedure ISI-120 Rev. 10.

Actions taken as a result of this item will be documented in the Inservice In -

spection Report for the Oconee 3 outage.