05000278/LER-1981-008-01, /01T-0:on 810211,main Isolation Valve on Loop B Mistakenly Isolated Instead of Loop a Valve During Installation of Test Connection to 1-inch Containment Atmospheric Dilution Line.Caused by Wrong Valve Designation

From kanterella
(Redirected from ML19347D252)
Jump to navigation Jump to search
/01T-0:on 810211,main Isolation Valve on Loop B Mistakenly Isolated Instead of Loop a Valve During Installation of Test Connection to 1-inch Containment Atmospheric Dilution Line.Caused by Wrong Valve Designation
ML19347D252
Person / Time
Site: Peach Bottom 
Issue date: 02/25/1981
From: Cooney M
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19347D251 List:
References
LER-81-008-01T, LER-81-8-1T, NUDOCS 8103110658
Download: ML19347D252 (1)


LER-1981-008, /01T-0:on 810211,main Isolation Valve on Loop B Mistakenly Isolated Instead of Loop a Valve During Installation of Test Connection to 1-inch Containment Atmospheric Dilution Line.Caused by Wrong Valve Designation
Event date:
Report date:
2781981008R01 - NRC Website

text

anc vCRu :ia um wuetsaa.ncut,a un e ::ce.u.sevN R Un!C 3 LICENSEE EVENT REPORT ReporC No. 3-81-OS/1T-0 TROL 8 LOCK: l l

l l

l l lh (PLE ASE PRINT OR TYPE ALL REQUIRED INFORMATION) 6 6

o l1l lP A lP lB lS l3 ! @l 0l 0l 10 l0l0l0lO!-l0lOl@l4l1l111l1l@l l

l@

s 9 LICEN5EE CoOE 14 IS LICEN5E NuwsER 26 M

LsCENSE Tvrt 40 S7 L A T 58 CON'T alil O'R" I L @l015 101 -l 012 17 18 GI O 1211 11181, @l 01212 !

! e 11 l@

8 60 6l DOCKET NUMSER 64 69 EVENT DATE 74 75 REPORT 0 ATE 83 EVENT DESCRIPTION AND PROSABLE CONSEQUENCES h o121l Vith the unit at full power. a 1" line en the ' A' loop of the CAD system I

oi3i l was blocked out to install a test connectien. A valve on the

'3' loop 1

o i4 l l was mistakenly isolated instead of the correct valve en the ' A' loop i

ois I resulting in a breach of primary centainment for about 00 minutes. The 1

016 l l error was discovered and the line isolated by closing the ' A' manual I

o;ll isolation valve. If a significant differential pressure developed, the I

o 1a, l line could have been isolated with this valve.

l

.0

'o*n" To'N su"E!!E suFo'of s M 'oE C

Cou,oscNTCoot olo!

I s i s l@ [Dj@ [ z_J@ l vl A l L i vi E l x l@ LF_j@ [D_j @

9 10 It 12 IJ 16 19 20 SfoUENTIAL OCCURRENCE REPORT REV'SioN LER/Ro EVENTYEAR REPORT No, Co0E TYPE No.

@,RE,y l2i8l1l

(--J l010I8l l.gj l 01 i l [T_j

[-j 10l 22 22 24 2s 21 a

n 20 si 22 TE N AC o P NT M N hours

$8 4 0

Po 3.

$UPPL R MANLFACTURER l G l@(J.j@

[3_j@

[z_J@

l0lol0l0l l Yl@

lNl@

(_Aj@

lR 13 !h 10 l@

33 34 3$

,)

37 40 44 43 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h iloll The event was caused by the i= proper designation of valve locatiens en I

iiii I a system check-off list resultirs in the valvirs error described above.

I

,i2i l When the valving error was discovered, the

'A' loop isolation valve was I

,i,il closed reestablisMy primary contain=ent integritf. The system cheek-l ip4l l off list has been corrected, and identification tars m2t en the valvea.

I e s 80 STA

% POWER oTHERSTATUS Das RY DISCoVERv QESCRIPTION i s I (,,E_j @ l 1 1 0 I Oj @ l N/A l

l A l@l Worker Observation l

' 87ivsTy i I o I LzJ @n o,o' STENT 4

C AMouMTo, ACT,vifv @ I toCuioN o, REu AsE @

REu AsE REuut lzl@l n/A I

N/A l

l PERSONNEL expos ES NUMSER TYPE DESCRIPTION 39 i I il l O I O I O l@L2Lj@l n_ i I

,ERsoN~EL mu'4Es otsCRiPrioN@

Nu.ER i la t 1010101@l n/A I

8 9 11 12 80 l

LOSS of oR oAwaCE To FACILITV TYPE DESCRIPTtoms i

i 19 I LzJ@l n/A I

G. 9 10 30 45$U DESCRIPTIONS 2iciudEet n/i -

i i i i i i i i i n ii ll

~b1 1

I9 h d2P f M M. J. Cooney (215) 841-5020 E OF PREPARER PHONE:

a