ML19345C893
| ML19345C893 | |
| Person / Time | |
|---|---|
| Site: | Sterling |
| Issue date: | 11/10/1980 |
| From: | Grier B NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Arthur J ROCHESTER GAS & ELECTRIC CORP. |
| References | |
| NUDOCS 8012080568 | |
| Download: ML19345C893 (1) | |
Text
_...
M4 FM
[
UNITED STATES
- NUCLEAR REGULATORY COMMISSION g
j REGION I O,
a 831 PARK AVENUE
% [ D
,o#
KtMo oF PRUSSIA. PENNSYLVANIA 19406 a
November 10, 1980 Docket No. 50-485
'{
Rochester Gas and Electric Corporation ATTN:
Mr. J. E. Arth'ur f
Chief Engineer
- I 89 East Avenue l;
7
]
Rochester, New York 14649 g
u E
a Gentlemen:
The enclosed IE Information Notice No. 80-41, " Failure of Swing Check Valve in the Decay Heat Res val Systes at Davis-Besse Unit No.1 " is forwarded to you for information.
No written response is required.
If you desire additional information regarding this matter, please contact this office.
Sincerely, Boyce H. Grier Director
Enclosures:
1.
IE Information Notice No. 80-41 2.
List of Recently Issued IE Information Notices CONTACT:
E. G. Greenman (215-337-5267) cc w/ enc 1s:
C. R. Anderson, Manager, QA Lex K. Larson, Esquire N. A. Petrick, Executive Director, SNUPPS Gerald Charnoff, Esquire 8012oso gg7
SSINS No.:
6835 Accession No.:
8008220260 UNITED STATES I 80-41 NUCLEAR REGULATORY C0994ISSION
(
OFFICE OF INSPECTION'AND ENFORCEMENT f-WASHINGTON, D.C.
20555
\\
November 10, 1980 IE Infomation Notice No. 80-41:
FAILURE OF SWING CHECK VALVE IN THE DECAY HEAT REMOVAL SYSTEM AT DAVIS-BESSE UNIT NO. 1 Description of Circumstances:
On October 9,1980 the resident inspector at the Davis-Besse facility was informed that the licensee had performed leak rate tests and identified exces-sive leakage through Decay Heat Removal System check valve CF-30.
Valve CF-30 is the inboard one of two in-series check valves that is used to isolate the reactor coolant system from the low pressure decay heat removal system.
On further investigation the licensee found that the valve disc and are had separated from the valve body and was lodged just under the valve cover plate.
The two 2 5/8 x 5/8 inch bolts and locking mechanism for the bolts that holds the are to the valve body were missing and have not been located.
The CF-30 valve is a 14-inch swing check valve manufactured by Velan Valve Corporation.
The cause of the failure has not been identified.
l' ducted in response to a letter from Darrell G. Eisenhut, Office of Nuclear The test that was in progress when the -failure was identified was being con.
Reactor Regulations to all Light Water Reactor Licensees, LWR Primary Coolant System Pressure Isolation Valves, February 23, 1980.
4 This IE Infomation Notice is provided as an early notification of a possibly significant matter that is still under review by the NRC staff.
It is expected that recipients will review the infomation for possible applicability to their facilities. No specific action or response is requested at this time.
If NRC evaluations so indicate, further ifcensee actions may be requasted or required.
No written response to this IE Infomation Notice is.equired.
If you have any questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.
J i
i
/
l
~
IE Information Notico No. 80-41 November 10, 1980 l
RECENTLY ISSUED IE INFORMATION NOTICES Information Subject Oate Issued to Notice No.
Issued 80-40 Excessive Nitrogen 11/f/80 All holders of Supply Pressure a power reactor OL Activates Safety-Relief or CP Valve Operation to Cause Reactor Oepressurization 80-38 Cracking in Charging 10/30/80 All holders of Pump Casing Ciudding a PWR power reactor OL or CP 80-37 Containment Cooler 10/24/80 All holders of a Leaks and Reactor power reactor OL Cavity Flooding at or CP Indian Point Unit 2 80-36 Failure of Steam 10/10/80 All holders of a Generator Support power reactor Bolting OL or CP.
80-35 Leaking and Dislodged 10/10/80 All holders of a Iodine-125 Implant Category G or G1 Seeds Medical License 80-34 Boron Dilution of 9/26/80 All holders of a Reactor Coolant During PWR Power Reactor OL Steam Generator Oecontamination 4
80-33 Determination of 9/15/80 All holders of Teletherapy Timer a teletherapy Accuracy license 80-32 Clarification of 9/12/80 All holders of Certain Requirements an NRC or Agreement for Exclusive-use State License Shipments of Radioactive Materials 80-31 Maloperation of Gould-8/27/80 All holders of Brown Boveri 480V-Type a power reactor K-6005 and K-Don 6005 OL or CP Circuit Breakers 1