ML19344A444

From kanterella
Jump to navigation Jump to search
LER 80-028/03L-0:on 800718,during Setpoint Surveillance, Solenoid Valve for Torus to Reactor Bldg Vacuum Breaker 3-1601-20A Determined Inoperative,Preventing Valve from Opening.Caused by Mechanical Failure.Valve Replaced
ML19344A444
Person / Time
Site: Dresden Constellation icon.png
Issue date: 08/14/1980
From:
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17192A889 List:
References
LER-80-028-03L-01, LER-80-28-3L-1, NUDOCS 8008200322
Download: ML19344A444 (1)


Text

__ -. ._ - -

~

'WC PCHM 064 ~ ~ ^ ~~ * - - - - -- - -

U. S. NUCL5AR REGULATCAY CCMMISSICN

'. M /l

, LICENSEE EVENT REPORT CCNTRCL SLOCX: l l l l l l (PLEASE PRINT CR TYPE ALL REculRED INPCRMATICN) l l l .3 la 33 l lI uCessEE 7

l Ll D Cl ctR l S l 3 lgls0 l 0 iuCENsE i4  :

- l 0 Nbusta l 0 l 0 l 0 l0 l-a l0 2al0 Igl4l1l1l1l1[gl ucENsE Tvet ;o srarse@

CCN'T ~

l0!ti [,"e[ l L @l O i 5l0l0l0l2l419 gl0[769l1 18 64 18 10 !@l 0 l 3 AEPORT EVENT DATE 74 is i l l a3 ATE 181040j@

7 4 60 61 OoCKET NLMSER EVENT CESCRIPTICN AND PRCBA8LE CCNSECUENCES h i

l o ! 21 lDuring normal operation while performing set point surveillance, solenoid valve for [

,,3j georus to Reactor Building vacuum breaker 3-1601-20A was determined to be inoperative, l

. , a ,, j ; preventing the valve from opening. This event is of mini =al safety significance l lia , g ; gsince redundant valve 3-1601-203 was immediately tested and proven operable (T.S. 3.7. A. l

!,a g i ;3.b). This is the first event of this nature.  ;

l ll 0 i 7 l l .

ji a ii! I 30 I

i7 8 9 COMP.

SYSTEM CAUSE CALSE VALV E C ct CecE suscocE COMPCN ENT CODE SUICCCE SUSCOCE ll o-l 9 l' 7 3 lS lA lh l E lh l3 l@ lV lAlLlVl0l?l@ lEl@ lzl@

3 10 11 12 13 18 13 20 SECUENTIAL CCOUARENCE AEPCRT 8EVISION EVENT VEA A REPCRT No. COCE Tvpt N gaf ag

@ ;(Eg l_l l0 l2 l8 l jfl l0 l3 [ lLj l_l l .l l210 22l0 l 23 24 26 27 28 23 NPMCJ 30 741ME COMP.

31 32 COMPCNENT ACTtCN suTumE EpsEC* $MUTOCWN ATTACNMENT TAKEN ACTt CN CN PLANT METHCO MCURS SUSMmED PCMM WS. SU P*LI E9 iAANUFACTURER ..

Ic !gl: z lg lsz ig l:szj@ l0 10 l0 l l lsi N l@ l Y lg l42N I@ lV l0 l9 1547l@

22 4 a si 40 42 44

, CAUSE CESCRIPTICN AND CCARECTivE ACTCNC h llijallThe cause of this event is attributed to the mechanical failure of the solenoid valve. l r

li;t i (The entire solenoid valve was replaced and the vacuum breaker tested satisfactor11v. l

,, ,7, lNo further corrective action deemed necessary. l I'}3l l llitai3 l3 i7 30 I

47CWER QTHER$TATUS Cl RY OISCCVERY 0E3CRIP9CN l ST A Ii ! 5 l l E lg l 0 l 9 l 6 lgl N/A l [3(gl Surveillance DIS 1600-3 l 7 3 3 t 12 11 44 45 de 90

  • Wt. EASED Op aELEA3E AMCUNT OF AC 1VITY LOCAT!CN Cp mELEASE N/A I I N/A I i2 ! s4 1%/l E f @ 10l z !@lf1 F 44 45 to
  • tR$CNNET. EN9C$1JR E5 NUM8E4 OESCRI8SCN d 12 i l 101010 l@l*v*E  ! @l N/A I 30
  • EuSCNNE N;LpiES I NUMSE4 OE3C3189CN 41 ll1 { ; } l 010 l0 [gl 'J/A

'g l

,7 3 3 11 12

! LOSS CP OR OAMACE TO 54CluTV -

  • v*E 3ESCmsTtCN

!b l .. ._

h I3l4 3 to 30 l7 *tSLiCITY ^ NRC uss CutY ,

iss :EsCain,C.NQ.5)

N/A 80082003.2.2 i i iiriiriiiiI!'

lI:13I I qE3!6l i 68 $9 30. ;

U *