Responds to NRC Re Violations Noted in IE Insp Rept 50-029/76-10.Corrective Actions:Plant Personnel Responsible for Source Checks Have Been Instructed to Perform Checks at Intervals Not to Exceed Six Months
ML19339B396
Person / Time
Site: Yankee Rowe
Issue date: 06/07/1976
From: French J
YANKEE ATOMIC ELECTRIC CO.
To: Nelson P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19339B392 List:
References
WYR-76-66, NUDOCS 8011060845
Download: ML19339B396 (2)


Text

.___

e-.d f it C h Y t G A N Y4 i,

,% ne (..

p Telephone cl7 366-90ll

  • 9 7tO-3 90 0739 YANKEE ATOIAIC ELECRIC 00lAPANY 20 Turnpoke Road Westborough, Massachusetts 01381 Yauxes June 7, 1976 United States Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 Attention:

Mr. Paul R. Nelson, Chief, Fuel Facility and Materials Safety Branch

Reference:

1.

License No. DPR-3 (Docket No. 50-29) 2.

USNRC Inspection Report No. 76-10, May 19,1976.

Dear Sir This letter is in response to your report, Reference 2, concerning a deficiency reported by your inspector.

Deficiency License Conditien 15A of Byproduct Material License 20-06216-01 requires that each ' sealed source centaining byproduct material, other than Hydrogen-3, with a half life greater than thirty days and in any form other than gas, shall be tested for leakage and/or contamination at intervals not to exceed six months.

Contrary to this requirement, four Co-60 sources of 1 millicurie, 1.71 millicuries, 35 19 millicuries and 115.9 millicuries, and one Cs-137 source of 50 curies were not tested between June 4, 1975 and February 1, 1976, an interval of eight months.

Response

Due to a misinterpretation of a letter from the AEC dated March 1,1974, it was assumed that all plant surveillance intervals could be adjusted

+25%.

Using this assumption and other operational considerations a source check war perfo med in June, 1975, approximately 25% earlier than scl.eduled.

Likewise, the January 1976 source check was approximately 255 later than the date of the surveillance schedule.