Forwrds Info Re Environ Qualification Tests to Be Conducted within 2 Yrs on Equipment to Be Used at Facility in Response to NRC 801001 Request.Schedules Are Set by Vendors & Util Contact
ML19339A674
Person / Time
Site: Fort Calhoun Omaha Public Power District icon.png
Issue date: 10/31/1980
From: William Jones
OMAHA PUBLIC POWER DISTRICT
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
NUDOCS 8011040507
Download: ML19339A674 (2)


Text

._ ._ _ . _ . -

l ..

I *.

.s\ ... .

.___-L...

Omaha Public Power District 9 1623 HARNEY e O M AN A. NEERASMA 68102 TELEPHONE S36-4000 AREA CODE 402 October 31, 1980 Mr. Darrell G. Eisenhut, Director Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C. 20555

Reference:

Docket No. 50-285

Dear Mr. Eisenhut:

l Omaha Public Power District received the Commission's letter dated l October 1,1980, requesting information on environmental qualification l tests to be conducted within the next two (2) years on equipment to be l used at the Fort Calhoun Station. In response to your request, the attached information is provided. Please note that the District is not {

funding the tests; therefore, the schedules are set by the vendors and a District contact has not been designated.

1 Sincerely,  ;

'ftUO W. C. J6nes Division Manager Production Operations WCJ/KJM/TLP:jnin Attachment '

cc: NRC Regional Office LeBoeuf, Lamb, Leiby & MacRae l

l l

\

, l l

8011040509 [ . . .. -

Q TRANSAMERICA DELAVAL INC.

FOXBORO GEMS SENSORS DIVISION

1. Equipment (type, model, XHTR, E-10 series XMTR, Model XM-54852 manufacturer, etc.) and RE-36562
2. The system where the Containment Pressure at Contain Sump Level Monitor equipment is installed Fort Calhoun Power Station at Fort Calhoun Power Station
3. The test location and Contact The Foxboro Co. Contact Gems Sensors Division schedule
4. The cognizant licensee Contact The Foxboro Co. Contact Transanerica Delaval, Inc.

contact for the test 38 Neponset Avenue Gems Sensors Division Foxboro, MA 02035 Plainville, CT 06062 2

4