05000265/LER-1980-022, Forwards LER 80-022/03L-0

From kanterella
(Redirected from ML19336A669)
Jump to navigation Jump to search
Forwards LER 80-022/03L-0
ML19336A669
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 10/15/1980
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19336A670 List:
References
NJK-80-412, NUDOCS 8010300441
Download: ML19336A669 (1)


LER-1980-022, Forwards LER 80-022/03L-0
Event date:
Report date:
2651980022R00 - NRC Website

text

O Commonwealth Edison Quad C; ties Nuclear Power Station 22710 206 Avenue North Coroova, lilinois 61242 Telephone 309/654-2241 NJ K-80-412 October 15, 1980 Mr. J. Keppler, Regional Di rector Of fice of Inspection and Enforcement Region til U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 Reference: Quad-Ci ties Nuclear Power Station Docket Number 50-265, DPR-30, Uni t 2 Appendix A, Sections, Table 3.7.1. and 6.6.B.2.b.

Enclosed please find Reportable Occurrence Report Number R0 80-22/03L for Quad-Ci ties Nuclear Power Station.

This report is submitted to you in accordance with the requirements of Technical Specification 6.6.B.2.b., as a condition leading to operation in a degraded mode permitted by a limiting condi tion for operation.

Very truly yours,

COMMONWEALTH EDISON COMPANY QUAD-CITIES NUCLEAR F0WER STATION

,A ] l pt//rfSD N.

J. Kalivianakis Station Superintendent NJK:JRW/bb Enclosure cc R. F. Janecek N. Chrissotimos a

1 OCT42 4 $801 8010300l{4([