05000302/LER-1978-018-04, /04X-0:on 780612,util Discovered Contractors Not Analyzing Environ Samples According to Procedures Providing LLD within ETS Limits.Sample Size & Count Times May Be Causing Higher Activity

From kanterella
(Redirected from ML19326A747)
Jump to navigation Jump to search
/04X-0:on 780612,util Discovered Contractors Not Analyzing Environ Samples According to Procedures Providing LLD within ETS Limits.Sample Size & Count Times May Be Causing Higher Activity
ML19326A747
Person / Time
Site: Crystal River 
Issue date: 06/14/1978
From:
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19326A746 List:
References
LER-78-018-04X, LER-78-18-4X, NUDOCS 8003030883
Download: ML19326A747 (1)


LER-1978-018, /04X-0:on 780612,util Discovered Contractors Not Analyzing Environ Samples According to Procedures Providing LLD within ETS Limits.Sample Size & Count Times May Be Causing Higher Activity
Event date:
Report date:
3021978018R04 - NRC Website

text

.O.

V

' 7PLEMENTARY INFORMATION port No.:

50-302/78-018/04X-0 2.

Facility:

Crystal River Unit #3 3.

Report Date:

14 June 1978 4

Occurrence Date:

May, 1978 (discovered 12 June 1978)

(determined at plant 14 June 1978) 5.

Identification of Occurrence:

Environmental samples were not analyzed by contractors using procedures which provided LLD's equal to, or less than, those required by Environmental Technical Specifications.

6.

Conditions Prior to Occurrence:

N/A 7.

Description of Occurrence:

The following samples had LLD's greater than those required by ETS for the below indicated period.

Seawater (6 stations)

May

(']

(# > ETS) 4 Shrimo (1 Station)

First Half 1977 (collected in May)

(9 > ETS) i Milk (1 Station)

May (V p ETS) 1 8.

Designation of Apparent Cause:

Sample size and count times of the samples may not have been sufficient to obtain LLD's within the ETS requirements.

Natural radiation background :nay also have caused activity in the samples which can result in high r LLD's.

9.

Analysis of Occurrence:

All seven of the nuclides that had greater than allowed LLD's had no detectable activities.

10.

Corrective Action

The annual average LLD for each of the seven nuclides is equal to, or less than, that required by the Environmental Technical Specifications.

Therefore, no corrective action 13 deemed necessary.

8008030 D

6 Failure aata:

(

)

k/

This is the ninth report for this type occurrence. Refer to:

LER 77-1112, dated 21 Sept. 1977 LIR 77-134E, dated 3 November 1977 LER 77-141I, dated 7 Dec. 1977 LER 77-144E, dated 15 Dec. 1977 LER 77-164E, dated 25 Jan. 1973 LIR 78-012/04X-0, dated 17 April 1978 LER 73-013/04X-0, dated 24 April 1973 LER 79-Oli/04X-0, dated 11 May '973