Text

__ _

__

O

p. %'e

7/c

-

,

UNITED STATES

/

84*-

'I-

NUCLEAR REGULATORY COMMISSION

/

se

< ,a

REGION V

8005150

o,

g

1990 N. CnLIFORNIA BOULEVARD

g

e

SUITE 202, WALNUT CREEK PLAZA

e,,,o

WALNUT CREEK, CALIFORNIA 94596

MR 7 1980

Docket N]. 50-361

Southern California Edison Company

P. O. Box 800

2244 Walnut Grove Avenue

Rosemead, California 91770

Attention:

Dr. L. T. Papay, Vice President

Advanced Engineering

Gentlemen:

Subject: NRC Inspection of San Onofre Unit 2

This refers to the inspection conducted by Messrs J. H. Eckhardt and

G. Hernandez of this office on February 12-15, 1980 of activities

authcrized by NRC Construction Permit No. CPPR-97, and to the discussion

of our findings held with Mr. D. E. Nunn and other members of your staff

at the conclusion of the inspection.

Areas examincd during this. inspection are described in the enclosed

inspection report. Within these areas, the inspection consisted of

selective examinations of procedures and representative records, in-

terviews with personnel, and observations by the inspector.

Based on the results of this inspection, it appears that one of your

activities was not conducted in full compliance with NRC requirements,

as set forth in the Notice of Violation, enclosed herewith as Appendix A.

This item of noncompliance has been categorized into a level as de-

,

scribed in our correspondence to all NRC licensees dated December 31,

l

1974.

This notice is sent to you pursuant to the provisions of Section 2.201,

of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal

Regulations.

Section 2.201 requires you to submit to this office,

within thirty (30) days of your receipt of this notice, a written statemer.t

_ _ _ _ -

_

_ _ _ _ - _ .

-

.

.

,

,

S6uthern California Edison' Company

-2-

MAR 71990

.

or explanation in reply including (1) corrective steps which have been

taken by you and the results achieved; (2) corrective steps which will

be taken to avoid further violations; and (3) the date when full compliance

will be achieved.

In accordance with Section 2.790 of the NRC's " Rules of Practice,"

. Part 2, Title .10, Code of Federal Regulations, a copy of this letter and

the enclosed inspection report'will be placed in the NRC's Public

Document Room.

If this report contains any information that you believe

to be proprietary, it is necessary that you submit a written application

to this office..within (30) days of the date of this letter, requesting

that such information be withheld from public disclosure. The application

must include a full statement of the reasons why it is claimed that the

.

information is proprietary. The application should be prepared so that

any proprietary information identified is contained in an enclosure to

the application, since the application without the enclosure will also

be placed in the Public Document Room.

If we do not hear from you in

this regard within the specified period, the report will be placed in

the Public Document Room.

Should you have any questions concerning this inspection, we will be

glad to discuss them with you.

Sincerely,

e'

'G. S. Spencer, Chief

..

Reactor Construction and

Engineering Support Branch

Enclosures:

A.

Appendix A - Notice of Violation

B.

Inspection Report

No.- 50-361/80-01

cc w/o enclosure:

R..Dietch, Vice President

Nuclear Engineering & Operations SCE