O REACTOR COOLANT SYSTEM -

.C.'

SURVEILLANCE REQUIREMENTS 4.4.9.3. 1 Each PORV shall be demonstrated OPERABLE by-a.

Performance of a CHANNEL FUNCTIONAL TEST on th'e PORV actuation .

chanhel, but excluding valve operation, within .31 days prior to -

entering a condition in which the PORV is required OPERABLE and at -

least once per 31 days thereafter when the PORV is required.0PERABLE. -

b.

Performance of a CHANNEL CALIBRATION or the PORV actuation channel, at least once per 18 months. - '

c. Verifying the PORV key switch is in the AUTO position and the PORV isolation valve is open at least once per '12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> when the PORV is being used for overpressure protection.
d. Testing pursuant to Specification 4.0.5. '

4.4.9.3.2 The RCS vent (s) shall be verified to be open at least o'nce .

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />

  • when the vent (s) .is being used for overpressure protection. per

> . .:,?

- 1

.I "Except when the vent. pathway is provided with a valve which is locked,  :

sealed, or otherwise secured in the open position, then verify these valves open at least once per 31 days.

. # . ** t O

... 1 NORTH ANNA ' UNIT 1 3/4432 8004210 } %

.