ML19323A564
| ML19323A564 | |
| Person / Time | |
|---|---|
| Site: | North Anna |
| Issue date: | 04/16/1980 |
| From: | Ferguson J VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| To: | |
| Shared Package | |
| ML19323A565 | List: |
| References | |
| 344, NUDOCS 8004210372 | |
| Download: ML19323A564 (3) | |
Text
-
J 4
VIMoINIA Ex.ucTmIc Ann Pownu CourAny
- Racumown.VamonwzA eness April 16, 1980 i
Mr. Harold R. Denton, Director Serial No. 344 Office of Nuclear Reactor Regulation LQA/WRM:rab i
Attn:
Mr. A. Schwencer, Chief Operating Reactors Branch No. 1 Docket No. 50-338 Division of Operating Reactors U. S. Nuclear Regulatory Commission License No. NPF-4 l
Washington, D.C.
20555
Dear Mr. Denton:
i i
AMENDMENT TO OPERATING LICENSE NPF-4
{
NORTH ANNA POWER STATION UNIT NO. 1
[
l PROPOSED TECHNICAL SPECIFICATION CHANGE NO. 32 i
Pursuant to 10 CFR 50.90, the Virginia Electric and Power Company requests an amendment, in the form of changes to the Technical i
l Specifications, to Operating License NPF-4 for the North Anna Power Station, Unit No. 1.
The proposed changes are enclosed and have been i
designated Change No. 32.
The North Anna Unit 1 Technical Specification Surveillance
[
Requirement 4.4.9.3.1.d requires testing of the pressurizer power operated relief valves in accordance with the inservice test requirements for ASME Category C valves pursuant to Specification 4.0.5. ASME Category C valve testing pursuant to Specification.4.0.5 is designed for valves which are self-actuating and does not apply to the pressurizer power operated relief-valves; therefore, a Technical Specification change to require testing of the pressurizer.
power operated-relief valves pursuant to Specification 4.0.5 is requested.
t Specification 4.0.5 requires ASME Code Class 1, 2, and 3 pumps and valves to be tested in accordance with Section XI of the ASME Boiler and Pressure Code (1974 Edition with Addenda through the summer 1975) except where specific written relief has been granted by the Nuclear Regulatory Commission. The cubicle in which the pressurtzer power operated relief valves are located is not accessible during normal operations _due to radiation levels which prohi--
bit direct measurement of valve stroke times. During operation in Mode 4, the test area has a radiation level of 100-200 mrem /hr. Testing the pressurizer power operated relief valves takes approximately one to two hours and requires a minimum of t5m people in the test area to perform; -therefore, the conditions cited above preclude the pressurizer. power operated relief valves being tested once every three months as required for ASME Category B valves pursuant to-Section XI of the ASME Boiler and Pressure Code without unacceptable radiation exposure to test personnel.
~We propose the following test program:
(1) The' pressurizer power operated relief valve will be l
cycled once every three months.
t
- Mene3n
ViaO NIA Ex.zcTa:C AND POWEa COMPANY TO Mr. Harold R. Denton 2
(2) The pressurizer po'/er operated relief valves will be tested for stroke' time, fail-safe operation, and remote position indication once every eighteen months during cold or refueling shutdown.
i This test program meets the testing requirements of ASME Section XI for Category B valves with the exception of test fregt ancy; therefore, in accordance with 10 CFR 50.55a.(g)(6)(1), an exemption to test the pressurizer power operated relief valve as described is requested. This proposed change will make the Unit 1 Specification identical to the currently approved Unit 2 Specification.
This proposed change has been reviewed and approved by the Station Nuclear Safety and Operating Committee and the System Nuclear Safety and Operating Committee. It has been determined that this request does not in-volve an unreviewed safety question.
We have evaluated this request in accordance with the criteria in 10 CFR 170.22. It has been determined that this request involves a single safety issue which is not a significant hazards consideration; therefore, a Class III license amendment fee is required. Accordingly, a voucher check in the amount of $4,000.00 is enclosed in payment of the fee.
Very truly yours, i
J..H. Ferguson l
Executive Vice President-Power Attachments:
1.
Proposed Technical Specification Change No. 32 2.
Voucher Check No. 17455 for $4,000.00 cc: Mr. James P. O'Reilly Of fice of Inspection and Enforcement Region II
COMMONWEALTH OF VIRGINIA )
)
S. S.
~
CITY OF RICHMOND
)
Before me, a Notary Public, in and for the City and Common-wealth aforesaid, today personally appeared J. H. Ferguson, who being duly sworn, made oath and said (1) that he is Executive Vice President-Power of the Virginia Electric and Power Company, (2) that he is duly authorized to execute and file the foregoing Amendment in behalf of that Company, and (3) that the statements in the Amendment are true to the best of his knowledge and belief.
Given under my hand and notarial seal this 1/ 7/ day of h Nil
/
My Commission expires i). ofMr y M >96) 4l h
/
Notary Public (SEAL)