ML19322B708
| ML19322B708 | |
| Person / Time | |
|---|---|
| Site: | Oconee |
| Issue date: | 11/22/1977 |
| From: | Parker W DUKE POWER CO. |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| Shared Package | |
| ML19322B705 | List: |
| References | |
| NUDOCS 7912050711 | |
| Download: ML19322B708 (2) | |
Text
i' m,
- l. s KE Powen COMPANY Powra Buit.mwo 422 SouTu CnuHcu STazer. CIIAHIMfTE, N. C. 2e242 wiwa o. eaaa ra. sa.
November 22, 1977
'/ec t PottsC(sof TCitP=ONE: AaCa 704 S e c *a. P=oouctio=
373-4083 Mr. J. P. O'Reilly, Director U. S. Nuclear Regulatory Commission Suite 1217 230 Peachtree Street, Northwest Atlanta, Georgia 30303 Attention:
Mr. J. T. Sutherland RE: RII:ADK 50-269/77-21 50-270/77-21 50-287/77-21
Dear Sir:
In response to your letter of November 4, 1977 which transmitted OIE Inspection Report 77-21, Duke Power Company does not consider informa-tion contained therein to be proprietary.
Please find attached our response to the apparent item of noncompliance.
Very truly yours, TAL.,0. PL William O. Parker, Jr.
%g MST:ge Attachment 79120507/I
.. - -. - ~ ~ - - - -
I.
.-o.
l RESPONSE TO OIE '^1PECTION REPORT 50-269, -270,
- '/77-18 I
J ITEM:
Technical Specification 6.4.1 requires that written procedures with appropriate instructions shall be provided for preventive or corrective maintenance which could affect radiation exposure to personnel.
Contrary to the above, procedure IP/0/A/360/lC, RIA-45 Vent Gas Monitor Low, specified an alarm setpoint higher than the alarm setpoint specified in PT/0/A/230/01, Radiation Monitor Check.
RESPONSE
All radiation monitoring procedures had previously been reviewed for references to setpoint alarms and these were revised to delete these references. The instance identified in the inspection report had apparently been an oversight.
Procedure IP/0/A/360/lc has been revised to delete reference to a specific setpoint.
Additionally, two independent reviews have been made of all radiation monitoring calibration procedures to confirm that all references to setting alarms and trips have been deleted.
,.. ~,
-c-y