_ - _ _ - _ _ _ - - _ _ - _

O l

t 1

I f

  • ao=
  • l oars o. oocu==r o.r...cen,.o H.G11Da F0WER CORPORATIGE 10/18/76 11/1/76 61108 ua ai.=o

.pon, _

or.

1 To Ga6 cG OTts. A L

ggg g 3 actio= =mcassaa' O

a cuamaaca O

    • '***a

.crio.

c==saa-O O

c= ear cm

.o., v.a

m. coo.

n ase o oesca*re= i=== ee -

gg ma.eamen 70/ jf l fars mecaeveo sv oars REPCEZAELE DEFICIENCT

(/

la /

r HvnaAHI Tr SNDERER 31837 GA5GE LE4EACg GCKEE

/

f R.A. EAR N

[f I

( AESQLVED )

. ccem,..

i Cor1Es 70R PEE, IACAL PSE, NSIC Am

/ /d.

i DTIE SIrr 10 REG 10m&L C00RDIN42CA ICE d-DIST11NTICE hY //

76 [A 8

! CCFT SEarl TO REG 105(113 i

I v s mucta4a a.outaron, cou ss.o=

,o,,,,c j j.%

p ##$p

,q l

8008040f/3

1 Qf

%/of e

Il wav Fkarkia

/

.P..o..w..e...r.

October 18, 1976 Mr. Dudley Thompson Acting Director Division of Field Operations Office of Inspection and Enforcement U. S. Nuclear Pegulatory Ccurnission Washington, D. C.

20545

Subject:

Docket No. 50-302 Control No. ID 1338 F2 We wish to advise you that the deficiency regarding the hydraulic snubber sight gauge leakage has been resolved. A new design for the sight glass has been approved; the manufacturer is supplying sufficient sight glasses to replace all such assenblies at the Crystal River Unit #3 site. In addition, replacenent oil reservoirs, to which they are attached, are being procured in the event that some might be dannged during the removal of the sight glasses. It is expected that all safety-related snubbers will be repaired by Decerber 15, 1976. The performance of these new sight I

glasses will be verified after installation, utilizing a snubber functional test device which Florida Power Corporation has purchased.

~

~

We bel'eviihis act'it completeHhose reifuireil tip Flori~da Powir Corporation -

~ i regarding this matter. If you have any further questions, please advise.

Yours very truly, NAl'4f.

J. T. Rodgers Assistant Vice President JTR/pb

.s a

General Office 32o1 nwy-kum street soun. P O. Box 14042. St. Petersburg, Fionda 33733 813-866-5151