05000302/LER-1978-007-04, /04X-0:on 780216 & 17,biomass of Fish & Shellfish Impinged on Intake Screens of Units 1,2 & 3 Exceeded 50 Kg Per 24-h Reporting Level.Coal Barge Exiting Intake Canal During Sampling May Have Been Partial Cause

From kanterella
(Redirected from ML19317G286)
Jump to navigation Jump to search
/04X-0:on 780216 & 17,biomass of Fish & Shellfish Impinged on Intake Screens of Units 1,2 & 3 Exceeded 50 Kg Per 24-h Reporting Level.Coal Barge Exiting Intake Canal During Sampling May Have Been Partial Cause
ML19317G286
Person / Time
Site: Crystal River 
Issue date: 03/08/1978
From: Cooper J
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19317G276 List:
References
LER-78-007-04X, LER-78-7-4X, NUDOCS 8002280905
Download: ML19317G286 (1)


LER-1978-007, /04X-0:on 780216 & 17,biomass of Fish & Shellfish Impinged on Intake Screens of Units 1,2 & 3 Exceeded 50 Kg Per 24-h Reporting Level.Coal Barge Exiting Intake Canal During Sampling May Have Been Partial Cause
Event date:
Report date:
3021978007R04 - NRC Website

text

_ _

__ =

0*

.~

ENVIRONMENTAL LICENSEE EVENT REPORT #78-007/04X-0

\\

D 1.

Facility:

Crystal River Unit #3 2.

Report Date:

8 March 1978 3.

Occurrence Date:

February 16-17,1978 (determined ac planc 7 March 1978) 4 Identification of Occurrence:

Biomass of fish and shellfish impinged on the intake screens of Units 1, 2 and 3 exceeded the 50 kg/24hr reporting level of Section 3.1.3 of the Environmental Tehenical Specifications.

5.

Conditions prior to Occurrence:

Unit #1 - All water circulation pumps operational.

Unit #2 - All water circulation pumps operational.

h Unit #3 - All water circulation pumps operational.

6.

Description of Occurrence:

During the period 1000 February 16,1978 and 1000 February 17, 1978, 165.75 kg of fish and shellfish were impinged on the intake screens of Crystal River Units 1, 2 and 3.

Of the 165.75 kg im-pinged, Unit 3 accounted for 136.22 kg (82% of total).

Four finfish species accounted for 130.78 kg (79% of total); bay anchovy 48%, pinfish 22%, Atlantic stingray 5%, silver perch di.

Two commercially utilized shellfish species, the pink shrimp and the blue crab accounted for 17.09 kg (10% of total).

Impingement of all other commercially utilized species was less than 1 kg during the period in question.

The remaining biomass imp 1nged was distributed among several species of fish and shellfish.

7.

Desianation of Accarent Cause of Occurrence:

The following unusual or periodic event was noted during the occurrence:

One coal barge exited the intake canal during the sampling period.

This event may have been partially responsible for the impinge-ment observed.

4 r

,-m-_- - - --

  • -<-a v - - - - w