ML19308D342

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 50-302/76-11 on 760615-18. Noncompliance Noted
ML19308D342
Person / Time
Site: Crystal River 
Issue date: 07/22/1976
From: Long F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Rogers J
DUKE POWER CO.
Shared Package
ML19308D335 List:
References
NUDOCS 8002270798
Download: ML19308D342 (2)


See also: IR 05000302/1976011

Text

__

O

.

._

"

. . -

...

..

p%

- *

o

(d

.

e>@

%

UNITED STATES

,y

&

NUCLEAR REGULATORY COMMISSION

l

$

h

REGION 18

~

e

3:e PeacHTnas sinner, n.w. suive sia

,

4, > .

/

ari.anta,amonaia sono

JUL 2 2197G

li. .le[fy*. Refer To:

IE.II:FJ

50-302/76-11

$M

.

Florida Power Corporation

ATTN: Mr. J. T. Rodgers

.

Assistant Vice President

l

Quality and Environmental

Departments

3201.34th Street, South

F,'C. Box 14042

Ct. Petersburg, Florida 33733

i;er_tlemen:

'

Ih1s refers to the inspection conducted by Mr. F. Jape of this office

p

on June 15-18, 1976, of activities authorized by NRC Construction

(

Permit No. CPPR-51 for Crystal River Unit 3 facility, and to the

discussion of our findings held with Mr. G. P. Beatty, Jr. - at the

conclusion of the inspection.

Areas examined during the inspection and our findings are discussed in

the enclosed inspection report. Within these areas, the insnacti~'

consisted of selective av==4 nation of procedures and representative

records, interviews with personnel, and observations by the inspector.

We have also avamined actions you have taken with regard to previously

identified enforcement matters and unresolved items. The status of

these items is identified in Section II and IV of the summary of the

enclosed report.

,

During the inspection, it was found that certain activities under your

license appear to be in noncompliance with NRC requirements. This item

and references to pertinent requirements are listed in Section I of the

summary of the enclosed report.

This notice is sent to you pursuant co the provisions of Section 2.201

s

of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal

Regulations. Section 2.201 requires you to submit to this office,

within 20 days of your receipt of this notice, a written statement or

explanation in reply including:

(1) corrective steps which have been

take- by you, and the results achieved; (2) corrective steps which

A

will se taken to avoid further noncompliance; and (3) the date when'

(

full compliance will be achieved.

'

8002 270 7Pf

. _ - -

__

~

.-

. _ . _ _

e

JUL 2 21976

,

~

,

_

'

.

.

Florida Power Corporation

-2-

,

.

In accordance with Section 2.790 of the NRC's " Rules of Practice,"

Part 2, Title 10, Code of Federal Regulations, a copy of this letter

and the enclosed inspection report will be placed in the NRC's Public

,

'

Document Room. If this report contains any information that you believe

to be proprietary, it is necessary that you submit a written application

to this office requesting that such information be withheld from pubile

disclosure. If no proprietary information is identified, a written

,

statement to that effect should be submitted.

If an application is

<

submitted, it must fully identify the bases for which informacion is

claimed to be proprietary. The application should be prepared so that

information sought to be withheld is incorporated in a separate paper

and referenced in the application since the application will be placed

in the Public Document Room. Your application, or written statement,

should be submitted to us within 20 days. If we are not contacted as

specified, the enclosed report and this letter may then be placed in

the Public Document Room.

Should you have any questions concerning this letter, we will be glad to

discuss them with you.

h

-

Very truly yours,

J

w % --[

c

F. J. Long, Chief

Reactor Operations and

Nuclear Support Branch

Enclosure:

-

~

IE Inspection Report No.-

-

-

50-302/76-11

.

cc:

G. P. Beatty, Jr.

Florida Power Corp.

P. O. Drawer 1057

Crystal River, Fla.

32629

.

.

$

-