-_

UCENSEE EVENT REPORT O

CONT-L 8 LOC %

i i

i i i

i j

m 0,.=,. :

7,O m 1

6

\\

Amt LCENSE NUM8ER '

PE Y

,,j l vi I.1 Cl ale 131 1o101-161 olo lo lo l-l nl nl 14Il I 11 111 I loi1I 8,9 14 15

,25 26 30 31 32 7.ArEcSaY "'r74' E 5

/

ooCxE7 NumeEa EVENT oATE' aEPoaf DATE ECONT l o l o I,[oj [IJ l o I s I o I--I o i 31012 I til 2 I 117I 71 si IoI2IoI217I71 8-57 58 59 60 61 68 69 74 75 80 EVENT DESCRIPTION N

,,,E.

gl During trouble shooting of Eaergency Safeguards Actuation System, high pressure l

~

7 89 80 S@ l injection was inadvertently actuated.

System drawing error was cause and appro-

-l 7 89 80 SG l priate design change request has been initiated.

Because of RC System condition.

I 7 89 80

@l this is considered to be the zero (o) cycle HPI.

l 7 89 80 gg L (77-7)-

l 7 89

peu, 80 E

CODE CDP.PONFNf CODE n

MANuF n

VOLATON

@E l Sl Fl W l Il Nl Sl Tl R l U l

@l l Xl Xl Xl Xl y

7 89 10 11 12 17 43 44 47 48 CAUSE OESCRIPTION

^

3[ l Design drawing showed incorrect ch'annel designation.

Desien chance has been i

7 89 80 Ql requested to correct channel feed designation.

l 7 89 80

,i i

~

s

% POWER OTHER STATUS C VE DeSCOVERY DESCMTON E

bLj l ol ol'ol I node s I W I

Alarm I

7 8' ' 9 10 12 13 44 45; 46 80 RELEASED OF AfL ASE AMOUNT OF ACTMTV LOCATION OF AELEASE E

l i

U l*

N/A l

l l

7 8 9

10 11 44 45 80 PERSONNEL EXPOSURES NUMBER TYPE DESCRIPTON

' gg l l l

l Ul N/A l

'7 89 11 12 13 80 FERSONNEL INJURIES NUMSER DESCMTON D

II I

I I

N/A I

7 89 11 12 80 OFFSITE CONSEQUENCES D2 I N/A l

7 89 80 LOSS OR OAMAGE TO FACILITY TYPE DESCAePTON

@Ul N/A l

7 89 10 80 PUDLICllY

@l N/A l

7 89 80 O AOOITIONAL FACTORS l

N/A l

Wd9 80 8I 8002270 89/

I 7 89

//q 80 NAME:

W. P. Stewart {(II /

(813) 866-4159 PHONE:

.F.

......?

~