05000254/LER-1980-007, Forwards LER 80-007/03L-0

From kanterella
(Redirected from ML19305D731)
Jump to navigation Jump to search
Forwards LER 80-007/03L-0
ML19305D731
Person / Time
Site: Quad Cities 
Issue date: 03/25/1980
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19305D732 List:
References
NJK-80-119, NUDOCS 8004150463
Download: ML19305D731 (1)


LER-1980-007, Forwards LER 80-007/03L-0
Event date:
Report date:
2541980007R00 - NRC Website

text

_

Commonwealth Edison Quad Cities Nuclear Power Station 22710 206 Avenue North Corcova, Illinois 61242 Telephone 309/65& 2241 NJ K 119 March 25, 1980 J. Keppler, Regional Director Office of Inspection and Enforcement Region lil U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Reference:

Quad-Cities Nuclear Power Station Docket No. 50-254, DPR-29, Unit 1 Appendix A, Sections 3 1, Table 3.1-3 and 6.6.B.2.a Enclosed please find Reportable Occurrence Report No. R0 80-07/03L for Quad-Ci ties Nuclear Power Station.

This report is submitted to you in accordance with the requirements of Technical Specification 6.6.B.2.a, as an engineered safety feature instrument setting which was found to be less conservative than those established by the Technical Specifications but which did not prevent the fulfillment of the functional requirements of the affected system.

Very truly yours, COMMONWEALTH EDISON COMPANY QUAD-CITIES NUCL R POWER STATION N. J. Kalivianakis Station Superintendent NJK/JCV/ san cc:

R. F. Janecek

/ C)()][

5

'lll MAR 31 1980 8 0041ggg jljb.f7)