05000249/LER-1980-007-03, /03L-0:on 800209,during Local Leak Rate Test of Containment Vent Line,Measured Leakage Exceeded Tech Specs. Investigation Showed Valve AO-3-1601-23 Leaking Through. Caused by Normal Expected Wear of Rubber Seats

From kanterella
(Redirected from ML19305B353)
Jump to navigation Jump to search
/03L-0:on 800209,during Local Leak Rate Test of Containment Vent Line,Measured Leakage Exceeded Tech Specs. Investigation Showed Valve AO-3-1601-23 Leaking Through. Caused by Normal Expected Wear of Rubber Seats
ML19305B353
Person / Time
Site: Dresden 
Issue date: 03/12/1980
From: Dunbar J
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML17192A582 List:
References
LER-80-007-03L-01, NUDOCS 8003190569
Download: ML19305B353 (2)


LER-1980-007, /03L-0:on 800209,during Local Leak Rate Test of Containment Vent Line,Measured Leakage Exceeded Tech Specs. Investigation Showed Valve AO-3-1601-23 Leaking Through. Caused by Normal Expected Wear of Rubber Seats
Event date:
Report date:
2491980007R03 - NRC Website

text

RC FOnM 336

~

U. S. Nu'CLE AR REGOI. ATbRY COM%tlSSION 7 771 LICENSEE EVENT REPORT c NTRO. stC.Co 1 I

I I

I l@

(PLEASE PRINT OR TYPE ALL REOUIRED INFORMATIOM i

6 c lil 1: I L I n l a IS 13 l@!O ! 01 -101010101 O l-1010 l@l 4 Il 111111 l@l l@

I a 9 u0aNsEE Coat is 1s v0E sin a eEa

=

uCENsE T**E a

$7 +^ t es

0 ri

, C i 1 hp "'li*j l Ll@l 3 l 3 10 l0 l0 l2 h [9 @! O I 210 l 9 ! S I O l@l 0 l 31112 l 510 l@

s 60 61 OG;K ET %,VSta 64 tE9 EVENT O ATE

4 76 AE'CRT C ATE SC EVENT CESORIPTION ArjD PACS ARE CONSEOUENCES h oi:I l During local leak ra:e test of the containment vent line, the ceasured leakage was c,3, l1,990 SCFH which is in excess of the Tech Spec. lini: for a single centaineant isolatio:}

3,4; l valve (29.38 SCFH).

Upon investigation A0-3-1601-23 was found leaking through.

No l

oi3j l leaka;;e was detec:ed at the other boundary valves. This event was of minimal safety l

aie1 significance because all leakage was con:ained in the vent line and was into the dry-l 3;;; lwell.

Similar even:s:

50-237/76-10, 79 ')l7 & 30-249/76-16.

l O i8 } l l

60 8 9 SYSTEM

CAUSE

CAUSE C OV P.

yA(vg C00E OOOE SL8000E C0YPONENT COC!

SUSC00E Sua0006 0l9l l 9 l D lh lE lh lF l h l Y l A l l l Y l I-l X ( h l 3l h l D l h 8

9 10 11 12 TJ 18 19

0 S E QUENTI AL COOURRENCE REFORT A E VISION gge oc EVENTVE48
  • E* ORT NO.

CODE Tvpf N3

@NuvSga aEaO=-

l Sl Cl

.l_l l0l0[7l jfl l0 l3 l lLl j _l l 0l 21 2

J 24 26 27

.s

.3 a

I.1 3:

ACTION FUTURE EFFECT SwuT30WN ATT Ackv f NT N ' a O.4

    • V E COvs.

Cov'CNENT YMEN ACTION ON PLANT YETHOD wobF5

$U5m TTED 80RY >US SUPPLt En V AP.UF ACTURE A lCjg[3, Zjg l Z lg l Z jg '.{,0 l 0 l 0 l

lNjg lYlg lylg jpj3lf, ln lg u

42 43 u.

4, 2._

CAUSE CESORIPTION AND CORRECTIVE ACTIONS h iol] A0-3-1601-23 was replaced and the vent line rategra.

The leakage was 3.71 SCFH.

Ao-l i

g3] l 3-1601-23 is a 18" rubber seated butterfly valve. model No. 2FII. Leakace was due to I 3

. 47; l normal expected wear of the rubber seats.

No further cerreceiv. action is deened

.y

,;3, ynecessary.

l 1 tall I

4 9 80 8 A0lLITY UETMCD OF STATUS

%*OWER OTHER STATUS D:500VERY OtSCOVERY DESCRIPTION

+

Local teep pare Tegri,,

l 15 l l Hl l o l 0 l n l@l y/A l {@

1 8 9 1Q 1:

11 44 45 46 80 ACTIVITY CONTENT EELE ASEC 08 RELEASE AVCUNT OF ACTIVITY LOCATION CF RELE ASE -

l6l l Zlh l

N/A l

l N/A l

1 8 9 10 11 44 45 60 PERSONNEL EX'CSURES NUv8EA Tv*E 25SCAiPTION 1 j 7 l 1 0l 0 l 0 l@l Z l@L N/A l

8 9 it 13 gg PERSONNEL iNJU AiES NUY!E8 OESCPIPfiON tbll0101Ol@l N/A l

8 9 11 12 LOSS CF CR CAMAGE TO FACILITY A TE oESem,TicN v43 8003190563 l c l l Z j@l N/A l

8 9 to 8C PUSLiCITY NRC USE ONLY 45 45 tut 0 CESCRieT'ON Of l Nh N/A l

l[ [g;;;g;;;9lj 2

8 9 10 68 69

83. ;

John Dunbar Ext. 41 9

sp DEVIATION REPORT My ovR No.

Commonwealth t6 son STA UNG YEAR N O.

D 3-80-10 PART jj T TwE G~ OE'lATION CCCJ U.E D 2/9/80 1A40 Cu :ainment vent line er.cessive leakage n...

SYSTEM AFFEC E0 PL/ NT CON 0lilON5 T! STING 600 g i i

Primary Centainment 9739 pf..y1 3,,;,, y, _3 0

te23 fywg3 0

YES NO cisCRiFitON CF iviM During local leak rate testing of containment vent line, the ecsured leak was 1990 SCFH.

Leakase is susoected to be through the AO-3-1601-23 valve.

DESCRIPTION CF CAUSE Unknown DTie AP:LICABLE IN ORMATICN All leakare is ^^ntained in the sent line.

EOUIPMENT C YE5 DR NO.

WR NO.

FAILU RE O N^

N/A NO2

'/9/80 RESPONil!LE SUF W:50R CATE PART 2 l OPE:AT!NG ENGINEERS COMMENTS Following replacement of the 3-1601-23 valve, an acceptable LLRT was obtained on 3-4-50: thus containment thru leakace was within the limits of the Tech. Specs. Tech. Spec. 4. 7. A. 2. g was exceeded for leakace throuch a sin 21e isol valve.

SAFETY-TYPE OF CEVIATION EVENT OF POTENTIAL TECH S EC NON-REPCRTABLE ANNU A!.

RELATED RE:ORTABLE CCCURRENCE PUBLIC INTEREST VIOLATION OCCURRENCE R EPOP.T I NG AR ISSUED 10CFR2

4 ngy YES X YES X i

Xl-30"AY NOTIF1CATICN l

NO NC 6.6.3.2.d REPORTABLE CCCURRENCE ACTION ITEM NO.

PROM?T ON-SITE NOTIFICATICN NUV~: = R R. M. Ragan 3/3/S0 0920 y@ 80-?/03L-0 I' EE CAIE

  • E TITLE CATE TIME 24-HOUR NRC NOTIFICATION PROMPT OFF-SITE NOTIFICATION Verbal m. Toncue 3-5-80 0900 F. Palmer 3/5/S0 11:30 AM 1

By PEGION iii CATE TIME TITLE DA'E Tiv 7ay J. Gilliom 3/5/80 11:35 Ax REGION lli a COL DATE T'ME TITLE OATE TivE RESPONSI SLE COYF ANY OFF! CE: INFyFVED OF 10CFR21 caN D : TicNs AND ta i o :::O=?

?.- Noc TITLE DATi iW Michael Wright 3/5/80 REviEA AND COMPLETED-M ERATING ENGiNEis GATE ACCEPTANCE BY STATION REVIEW D' /M W d 0[4 W ['

i AS RECulREC

~

i g

DATE 3 '~M -N O

RESOLUTION APPROVEC ANC W

$!/3//d s

m AUTHORIZED FOR CISTRIBUTION STATION SvPERINTENDENT CATE Sf*lt's 10-77 18Chu iS=51-ti