Notice of Violation from Insp on 791016-19
ML19296C092
Person / Time
Site: Grand Gulf  
Issue date: 10/26/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML19296C067 List:
References
50-416-79-26, 50-417-79-26, NUDOCS 8002250204
Download: ML19296C092 (1)


Text

.

P APPENDIX A NOTICE OF VIOLATION Mississippi Power and Light Company License No. CPPR-119 Grand Gulf Based on the NRC inspection October 16-19, 1979, certain of your activities were apparently not conducted in full compliance with NRC requirements as indicated below.

These items have been categorized as described in correspondence to you dated Decembe.- 31, 1974.

As required by Criterion V of Appendix B to 10 CFR 50, and implemented by PSAR Section 17.1.5, " Activities affecting quality shall be prescribed by documented procedures and shall be accomplished in accordance with these instructions procedures.

Paragraph 4.12 of Appendix C to Specification 9645-C-19) 0, " Materials Testing Services" states "... mea-suring and testing devices used in checking quality shall be calibrated and documented at established periods against valid standards having known relationships to national standards where they exist."

Paragraph 6.21 of Specification 9645-C-191.0 requires that the soils and concretc laboratory be equipped with calibrated equipment for the performance of all field tests required under the specification.

This equipment is to include all testing devices and apparatus listed in applicable ASTM specifications.

Paragraph 8.3.5 and 11.3e require that sieve analyses be done on agggregates in accordance with ASTM C-136-71 and on granular backfill in accordance with ASTM D422-63. ASTM Cl36-71 and ASTM D422-63 state that sieves used shall conform to ASTM E-11.

Contrary to the above, sieves used fer particle size analysis of aggregates and soils are not calibrated or checked for conformance to ASTM E-11.

This is an infraction.