B ALT' ORE G AS AF ILECTRIC COM P ANY P. C. o - 4 147$

B A LTIMOR E. M A R YL A N D 21203 ELECTRIC PRODUCTION DEPARTMENT BY. M ARYLAND 2 57 March 14,1979 Mr. Boyce H. Grier, Director Docket No. 50-317 Office of Inspection and Enforcement License No. DPR-53 U.S. Nuclear Regulatory Comission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Grier:

Per Environmental Technical Specification 5.6.2.a. please find attached the fourteen-day report for LER 79-07/4T.

Should you have any questions regarding this report, we would be pleased to discuss them with you.

Very truly yours, k b kaiul{

L. B. Russell Chief Engineer LBR/RFE/dds Attachment Copy To:

Director, Office of Management Information and Program Control Messrs. A. E. Lundvall, Jr.

J. B. Bullock I\\ 0Y 0

L 9 1

7903210113 L

L i

LICI..iEE EVENT REP 0F.! <.-07/ 4T CO:"ET NO. 50-317 Den *DT DATE 03/14/79 E.< ai DATE 02/28/79 ATT*CHMENT EVENT DESCRIPTION AND PROBABLE CONSE00ENCES:

(CONT)

During normal operation a watchstander observed a blackish colored liquid covering the ground in the vicinity 6f the sulfuric acid storage tank. The system was isolated and the leak arrested. The material was identified as sulfuric acid.

It is estimated that less than 5 gallons of concentrated sulfuric acid was discharged to the bay via the storm drains.

CAUSE DESCRIPTIONS AND CORRECTIVE ACTION:

(CONT)

The cause of this reportable occurrence has been determined to be failure of a pipe weld. Immediate corrective action involved isolation of the tank.