05000302/LER-1979-050-03, /03L-0 on 790510:count-rate Amplifier & Rate of Change Amplifier for Nuclear Source Range Instrument NI-2 Found Inoperable.Caused by Amplifiers Being Out of Tolerance Due to Instrument Drift.Amplifiers Recalbr & Returned to

From kanterella
(Redirected from ML19259C143)
Jump to navigation Jump to search
/03L-0 on 790510:count-rate Amplifier & Rate of Change Amplifier for Nuclear Source Range Instrument NI-2 Found Inoperable.Caused by Amplifiers Being Out of Tolerance Due to Instrument Drift.Amplifiers Recalbr & Returned to Svc
ML19259C143
Person / Time
Site: Crystal River 
Issue date: 06/04/1979
From: Cooper J
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19259C137 List:
References
LER-79-050-03L, LER-79-50-3L, NUDOCS 7906120407
Download: ML19259C143 (2)


LER-1979-050, /03L-0 on 790510:count-rate Amplifier & Rate of Change Amplifier for Nuclear Source Range Instrument NI-2 Found Inoperable.Caused by Amplifiers Being Out of Tolerance Due to Instrument Drift.Amplifiers Recalbr & Returned to Svc
Event date:
Report date:
3021979050R03 - NRC Website

text

-)

hac FOraad %6

(*

U.S. huCLC An Rf CVLATOftY COM*44540Pi L!CENSEE EVENT REPORT EXHIBIT A coNinot Stocic. I I

l' I I l l@

tetrast enar on tyra Att atouias o iNronwaricN) i q Rl P 3 lg-[ 0 l 0 l-l 0 l 0j 0 j Oj 0 1 -[0 g 0 ;gj j. l l l 1 ;g _ l _ ; g 4

1

'] F I Ll g

l o i uusses w6 i.

uuss. s v..a n

2.

.iu %a

..a s > s. : w CON'T

,"C,U Q @l0[ 5[0 t -to ; 3:0 ; 2 QI O I 511 l o f 71 9i@l 01 61 0 4! 71 91@

o i

.a coc.ars., sea au=r o4ie a

's

...ua r o. s a

.a EVENT Of 5CRieflord Arid eAOS A8t1 CONSEQUENCES g, In Mode 6, while calibrating th eactor Protection System, Surveillance t

Procedure SP-112, it was discovered that the count-rate amplifier and the r;nsi i g rate of change amplifier for Nuclear Source Range Instrument NI-2 were g

B TG 1 inoperable. This created an event contrary to Technical Specification

3.9.2.

Redundancy NA.

No effect upon public health and safety as the plant remained in a safe shutdown condition. This is the second occurrence

, for NI-2.

Reference LER 78-39.

1 l

s

.s S. l f t *.i C a*Jst Ca;13 Co".

satst e

CODE COCE SL5C004 CC ? cstN? :oct li 5:001 av. 0:4 g

i I l A ]@ W@ W @ l I I NI S I T l RI U l@ [_Yj @ @. @

I 8 4 d 85'0*d I

st CCC'4 9 8 t %CI T

st e.C.s tia l.

. t

  • 0.*I I

t

? so.

Coct so gg, 3

isist vtaa

@ gi g 17 19 l

[--.J 10 l5l 0]

y i Of3l IL l

[--J LOJ

_2 a

o a

2 n

dlg lJP's'd.,k(

'di.,Q,n a,w.cwir.;:.m u'st' n't vi.'

L.,l @ i l. ] @ / :

2:@, LLO I

'i

>nr-BjD j l

o L.N,Jg l

i (YJ@

I l

cAust otscaieries Au ccut:rn a A: ics5 @

A [ The cause of this event is attributed to the couno-rate amplifier and the f

, rate of change amplifier being out of tolerance due to instrument drif t.

Both amplifiers were calibrated and NI-2 was returned to service at 0735 on 5/10/79 following satisfactory completion of SP-ll2.

No further correc ;

gl tive action required.

or-i. it.ru @ s',sif'

,:1.... m:.... v. @

'#m?

% :ssi.

[Hj @ l0I 0l0l@l NA l

11@l Technician observation 1

l v s

'.e'r.u r, c:iisr

".: Nr 0, a:Teutv h l tocar.n ce.tta a:a @

arteasto. af.c us 4.

[Z_J Qlgl NA l

NA I

i 6

,..o,.. 'ai s.,a.s 'I ss m;....., @

s,....

i - 10 010 !@[ Zj@l NA l

' *.... m.;'...'l ii l 0 l. 0.h lgl,,:.....es@

s.

i l

NA l

i.

o i:

io

.o.,.s e, e. :,4va t.o.o ac... r.

v :

eis. u -.

[Zjg[

NA j

o

.,_,T ' o?,'....os @[g Nac est v.t -

b, 8,1 NA l [tttt9 i i ttl

o p. Cooper (904) 745-648(3 Nava or eateA

,o (SEE ATTA D SUPPLEMENTARY INFORMATION SHEET) gem D Vn

~

^

~~~

~

~1

[

l r

da L'

7906120 @ 7 1 _

\\

SUPPLEMENTARY INFORMATION Report No.:

50-302/79-050/031-0 Facility:

Crystal River Unit #3 Report Date:

4 June 1979 Occurrence Date:

10 May 1979 Identification of Occurrence:

One (1) neutron flux monitor (NI-2) inoperable contrary to Technical Specification 3.9.2.

Conditions Prior to Occurrence:

Mode 6, refueling.

Description of Occurrence:

In Mode 6, at 0800, while calibrating the Reactor Protection System through Surveillance Procedure SP-ll2, it was dis-covered that the rate of change amplifier and the count-rate amplifier for Nuclear Source Range Instrument NI-2 were out of tolerance. Calibration restored operability and NI-2 was returned to service at 1345 on 5/10/79.

Designation of Apparent Cause:

The cause of this event is attributed to instrument drift in the count-rate and rate of change amplifiers.

Analysis of Occurrence:

No effect upon public health and safety as the plant remained in a safe shutdown condition.

Core alterations were not in progress at the time of this event.

Corrective Action

The count-rate amplifier and the rate of change amplifier were calibrated and NI-2 was returned to service at 1345 on 5/10/79 following satisfactory completion of SP-ll2.

No further corrective action is required.

Failure Data:

This is the second occurrence reported for NI-2.

Reference LER 78-39.

2284

]29

/rc