05000302/LER-1979-112, Supplemental Info to LER 79-112/04X-0:on 800109,marine Plant & Vegetation Samples Had LLD Greater than Ets.Caused by Inadequate Sample Time & Use of Different Analyzing Equipment.No Corrective Action Proposed

From kanterella
(Redirected from ML19257C632)
Jump to navigation Jump to search
Supplemental Info to LER 79-112/04X-0:on 800109,marine Plant & Vegetation Samples Had LLD Greater than Ets.Caused by Inadequate Sample Time & Use of Different Analyzing Equipment.No Corrective Action Proposed
ML19257C632
Person / Time
Site: Crystal River 
Issue date: 01/10/1980
From:
FLORIDA POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19257C631 List:
References
LER-79-112-04X, LER-79-112-4X, NUDOCS 8001290516
Download: ML19257C632 (2)


LER-1979-112, Supplemental Info to LER 79-112/04X-0:on 800109,marine Plant & Vegetation Samples Had LLD Greater than Ets.Caused by Inadequate Sample Time & Use of Different Analyzing Equipment.No Corrective Action Proposed
Event date:
Report date:
3021979112R00 - NRC Website

text

.

SUPPLEMENTARY INFORMATION Report No.

50-302/79-112/04X-0 Facility:

Crystal River Unit #3 Report Date:

10 January 1980 Occurrence Date:

First and Second Halves 1979 (discovered 10 December 1979)

(confirmed 7 January 1980)

(determined at plant 9 January 1980)

Identification of Environmental samples were not analyzed using Occurrence:

procedures which provided LLDs equal to, or less than, those required by the Environmental Technical Specification 3.2.2.

Conditions Prior to NA Occurrence:

Description of The following sample had an LLD greater than that Occurrence:

required to the date indicated below:

MARINE PLANr (2 stations)

FIRST HALF (4 > ETS) 1 VEGETATION (3 stations)

SECOND IIALF

( e > ETS)

J Descrip*. ion of Inadequate sample time w the apparent cause of Apparent Cause:

the greater than required LLD.

A contributing factor may also have been the use of analyzing equipment other than that normally used because of equipment failures.

Analysis of The activity associated with Sr-89 at Station C29 Occurrence:

(Control) for Marine Plants in the First Half was 28 pC1/kg and for the Second Half, it was nondetectable.

For Station C30 (Control), tne activity was nondetectable for the first half and 9 pCi/kg for the second half.

The activity is considered erroneous because of the different equipment being employed for analyzing these samples.

The activity associated with Zn-65 at Station C05 for vegetation in second half was nondetectable as was the activity for 2n-65 for all three stations in both the first and second halves.

Bright (LER)(N-88) 1821f 019 sco moo S M

Supplementary Information Page 2

Corrective Action

The LLD for Sr-89 from Sample Station C29 (Control) for Marine Plants in the first half was 11 pCi/kg and it was 3 pCi/kg in the second half.

The average annual LLD is 5 pCi/kg compared to the Technical Specification requirements of 10 pCi/kg.

The LLD for Zn-65 f rom Sample Station C05 (Control) for vegetation in the second half of 1979 was 15 pCi/kg.

The required LLD is 20 pCi/kg and the average annual LLD was 15 pCi/kg.

Analyses are perf ormed in such a manner that the required LLDs will be achieved under routine conditions.

Occasionally, background fluctuations, unavoidable small samples sizes, the presence of interfering nuclides, or other uncontrollable circumstances may render these LLDs unachievable.

For example, the energy of the Zn-65 gamma is about the same as the average gamma from the Compton Effect of K-40.

When there is unexpected K-40 activity in a sample, it will influence the Zn-65 LLD even though there may be no Zn-65 activity.

Therefore, no corrective action is proposed.

Failure Data:

This is the thirteenth (13th) report for this type occurrence.

Bright (LER)(N-88) i82f 020