PLAtlT SYSTEMS 3/4.7.5 HYORAULIC SN'JSBERS LIMITING CONDIT'ON FOR OPERATI0il 3.7.5 All hydraulic snuboers shown in Table 3.7.5-1 shall be OPERABLE.

APPLICABILITY:

CONDITIONS 1, 2 and 3 ACTION:

With one or more hydraulic snubbers inoperable, restore the inoperable snuober(s) to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hcurs.

SURVEILLANCE REQUIREMENTS 4.7.5.1 Hycraulic snubbers shown in Table 3.7.5-1 shall be demonstrated OPERABLE by the performance of the follcwing augmented inservice inspec-tion program and the requirements of Specification 4.0.5.

4.7.5.2 Each hydraulic snubber with seal material fabricated from ethylene propylene or other materials demonstrated compatible with the operating environment and approved as such by the NPC, shall be deter-mined OPERABLE at least once after not less than 4 months but within 6 months of initial criticality and in accordance with the inspection schedule of Table 4.7.5-1 thereafter, by a visual inspection of the snubber or functional operability test.

Visual inspections of the l

snubbers shall include, but are not necessarily limited to, inspection of the hydraulic fluid reservoirs, fluid connections, and linkage con-nections to the piping and anchors.

Initiation of the Table 4.7.5-1 inspection schedule shall be made assuming the unit was previously at the 6 month inspection interval.

4.7.5.3 Each hydraulic snubber with seal material not fabricated from ethylene propylene or other materials demopstrated compatible with the operating environment shall be determined OPERABLE at least once per 31 days by a visual inspection of the snubber.

Visual inspections o# the snubbers shall include, but are not necessarily limited to, inspection of the hydraulic fluid reservoirs, fluid connections, and linkage connections to the piping and anchors.

BRUNSWICK - UNIT 1 3/4 7-9

.$. o2

TABLE 3.7.5-1 en sal'ETY RELATED llYDRAULIC SNilBBERS*

n E

us lilGli ESPECIALLY Q

SNUBBER ACCESSIBLE OR RADIATION DIFFICUI.T NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE ZONE **

TO REMOVE (A or I)

(Yes or No)

(Yes or No) g U

IE21-2SS16 Core Spray React.or Bidg.

O' A

No No 2SS17 13' A

No No 2SS18 14' A

No No 15SS19

-3' A

No No 15SS20

-3' A

No No 28SS23

-4' A

No No 2SS31 68' A

No No 2SS32 66' A

No No w) 6SS41 70' A

No No 6SS42 69' A

No No y

1 25SS91

-6' A

No No 25SS96

-6' A

No No

~

40SS106

-12' A

No No 40SS107

-12' A

No No 39sS108

-12' A

No No 39SS109

-12' A

No No 3SS46 Drywell 63' I

No No 3SS47 63' I

No No 3SS48 65' I

No No

-3SS49 66' I

No No N-7SS53 63' I

No No N-7SS54 63' I

No No 7SS55 65' I

No N

7SS56 66' I

No No W

TABLE 3.7.5-1 SAFETY RELATED llYDRAllLIC SNUhBERS*

g E

un M

llIGli ESPECIALLY Q

SNUBBER ACCESSIBLE OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE ZONE *A TO REl10VE g

(A or I)

(Yes or No)

(Yes or No)

U IG31-ISS3 Reactor Water Cleanup Drywell 54' I

No No IB21-51SS103 Condensate Drain Drywell 29' I

No No 51SS105 29' 1

No No 51SS106 26' I

No No 50SS109 18' I

No No 50SS111 31' I

No No SISSll3 28' I

No No SISS115 23' I

No No u3 51SS118 24' I

No No IC11-16SSI Control Rod Drive Drywell 69' 1

No No y

,L 16SS6 63' I

No No 16SS7 69' I

No No 16SS8 70' I

No No 16SS10 72' 1

No No 16SS11 72' I

No No 16SS12 72' I

No No IE41-4SS44 liigh Press. Coolant. Inj.

Drywell 40' I

No No 4SS45 35' I

No No 4SS47 40' I

No No 4SS49 37' I

No No 4SS50 50' 1

No No 4SS51 30' I

No No 60SS9

~

Reactor Bldg.

4' A

No No y

6SS27

-5' A

No No N

6SS28 l'

A No No

+

-4

TABLE 3.7.5-1 en SAFETY RELA'IED flYDRAULIC SNUBBERS *

o E

m llIGil ESPECIALLY Q

SNilBBER ACCESSIBLE OR RADIATION DIFFICULT NO.___

SYSTEM LOCATION ELEVATION INACCESSIHLE ZONE **

TO REMOVE (A or I)

(Yes or No)

(Yes or No) g U

IE41-6SS30 Migh Press. Coolant Inj.

-l' A

No No 6SS32

-5' A

No No 6SS33 l'

A No No 6SS35

-1' A

No No 6SS36

-5' A

No No 6SS37 0'

A No No 6SS38 l'

A No No 6SS40 2'

A No No u) 6SS42

-4' A

No No 60SS52 41' A

No No y

,L 6SS64

-l' A

No No u

61SS71

-4' A

No No 61SS72

-l' A

No No 61SS73

-2' A

No No 61SS76 37' A

No No 61SS77 37' A

No No 44SS84 14' A

No No 44SS86 14' A

No No 44SS98 12' A

No No 61SS99 22' A

No No 61SS100 17' A

No No M-60SS101 42' A

No No N

60SS102 42' A

No No N '

19sS103

-3' A

No No

'2SS104 12' A

No No f

2SS105

-17' A

No No A

l.J1

TABLE 3.7.5-1

_ SAFETY RELATED llYDRAULIC SNUBBERS _*_

m E

vs lilGli ESPEC I Al.LY Q

SNUllBER ACCESSilll.E OR RADIATION DIFFICULT NO.

SYSTEM I.0 CATION ELEVATION INACCESSIBLE 7.ONEf-k TO REMOVE (A or I)

(Yes or No)

(Yes or No)

U IE41-2SS106 liigh Press. Coolant Inj.

-12' A

No

'lo 22SS178

-11' A

No No 20SS195 4'

A No No 20SS196 4'

A No No 22SS197 13' A

No No ISGT-8SS17 Standby Gas Treatm.

Reactor Bldg.

69' A

No No lil21-70lSS164 Instrument Sensing Drywell 104' I

No No 70lSS167 104' I

No No m) 70lSS169 100' I

No No 70lSS170 103' I

No No y

,1, 70lSS171 99' I

No No e

70lSS172 101' I

No No 70lSS175 100' I

No No 70lSS177 94' I

No No 70lSS178 97' I

No No 70lSS179 96' I

No No 70lSS184 88' I

No No IRCC-32SS30 RX Closed Cooling Wtr.

Reactor Bldg.

55' A

No No 32SS45 60' A

No No 36SS78 54' A

No No

~

37SS79 54' A

No No N'

39SS80 59' A

No No N

38SS81 54' A

No No 7SSI12 57' A

No No j

47SS167 59' A

No No 47SS168 58' A

No No a

Os

T_A_BLE 3.7.5-1 m

SAFETY RELATED llYDRAULIC SNUBBERS *

n E

m llIGli ESPECIALLY Q

SNUllllER ACCESSIBLE OR RAl)lATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIHLE_

Z_0NE?i _

TO REM 0_VI-]

(A or I)

(Yes or No)

(Yes or No) g U

IRCC-48SS169 Rx Closed Cooling Wtr.

60' A

No No 50SS272 Outside Drywell 4'

A No No 60SS121 Drywell 17' I

No No 60SS122 16' I

No No 65SS128 7'

I No No 65SS129 9'

I No No 71SS139 9'

I No No 73SS145 5'

I No No wy 19SS157 21' I

No No 19SS160 29' I

No No y

,L IPSN-A2SS30 Primary Steam Drywell 65' I

No No

'a A2SS31 64' I

No No A3SS32 40' I

No No A3SS33 35' I

No No A3SS34 35' I

No No A3SS35 41' I

No No ASSS38 22' 1

No No ll2SS40 63' I

No No ll2SS41 64' I

No No Il3SS42 40' I

No No d

B3SS43 35' I

No No N

ll3SS44 40' I

No No IGSS46 46' I

No No ll3SS47 35' I

No No

. Il3SS48 40' I

No No p.

B5SS50 18' I

No No N

)

YTEo LLV N

LUO ACM r

I I E o

oooooooooooooooooooooooooo CFR NNNNNNNNNNNNNNNNNNNNNNNNNN EF s

PI O e

SDT Y

E

(

)

N

.o O

N I

  • T*

r oooooooooooooooooooooooooo i

GAE o

NNNNNNNNNNNNNNNNNNNNNNNNNN l

I I N DO s

l l

A Z_Ye R

(

R OEL)

EBL 1_I S

r l

l iS o

I I I I I I I II I I II I I I I I I I I I I I I 1 SE SCA EC(

CA CN AI

  • SR E

B N

B O

'2'34'0'5'0'8'598'2'550'551 '2 '2 '2 '2 '1 '9990 U

I N

T 2664343331 2664334244433334 S

AV 1

C E

I L

L E

5 U

7 AR 3

D Y

L I

N I

E 1

O l

B D

I e

A E

T T

T A

wy A

C r

L 0

D E

I R

YTEF S-A M

m E

a T

e S

t Y

S S

yra m

C I

ir C

P R

R E

B.

BO 022 UN I4567801 2458901 236979 N

S55S556666666777771 2256768 S

SSSSSSSSSSSSSSSSSSSSS44466 SSSSSSSSSSSSSSSSSSSSSSSSSS S22333333SS223333S333SSSSS BCCCCCCCCCCDDDDDDDBCA43344 1

N S

5 P

E I'

I

?

yw

.MC O

t=:E% sS s @U-uD uL.*

a

TABLE 3.7.5-1 SAFETY RELATED llYDRAULIC SNUBBERS

  • lilGli ESPECIALLY N

ACCESSIlli.E OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE ZONE *k TO REMOVE Q

SNUBBER (A or I)

(Yes or No)

(Yes or No)

E l1 40' I

No No 39' I

No No 1E51-4SS69 RCIC 4SS70 36' I

No No 4SS71 31' I

No No 4SS72 30' I

No No Reactor Bldg.

40' A

No No 4SS73 41SS51 20' A

No No 42SS74 20' A

No No 42SS75 18' A

No No

)

42SS76 5'

A No No u

42SS17 0'

A No No

,8 42SS78 4'

A No No y

42SS79

-13' A

No No 42SS80

-16' A

No No 42SS81

-9' A

No No 42SS82

-9' A

No No 40SS83

-9' A

No No 40SS84

-12' A

No No Q,

40SS85

-9' A

No No N

40SS86

-15' A

No No 40SS87

-13' A

No No 40SS88 41' A

No No 41SS89 41' A

No No 41SS95

-17' A

No No w

19SSil3

-16' A

No No 19SS114 O'

A No No 19SS129

TABI.E 3. 7. 5_-l_

SAFETY RELATED IIYDRAULIC SNUBBERSf; g

E en d

lilGli ESPECIALLY Q

SNUBBER ACCESSIBLE OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBI.E ZONE **

TO REMOVE (A or I)

(Yes or No)

(Yes or No) g U

IB21-44SS129 Nuclear Steam Vent Drywell 104' I

No No 44SS131 93' I

No No 44SS134 99' I

No No 44SS136 97' 1

No No 44SS137 96' I

No No 44SS138 95' I

No No 44SS141 87' I

No No 44SS142 87' I

No No w) 44SS143 87' I

No No 44SS146 87' I

No No y

,L 44SS147 82' I

No No 44SS149 85' I

No No 44SS150 83' 1

No No 47SS155 75' I

No No 47SS156 78' I

No No 47SS157 75' I

No No IC41-9SS4 Standby Liquid Cont.

Drywell 63' I

No No 9SS5 47' I

No No

"~

9SS8 42' 1

No No 9SS10 38' I

No No 9SS11 39' I

No No A

9SS12 69' I

No No 9SS13 52' I

No No (54 9SS26 Reactor Bldg.

72' A

No No CD 9SS27 72' A

No No 6SS34 84' A

No No

TABLE 3.7.5-1 SAFETY _RELATED llYDRAULIC SNUBBERS

  • E h

IIIGli ESPECIALLY Q

SNUBBER ACCESSIBLE OR RADIATION DIFFICULT NO.

SYSTEtt LOCATION ELEVATION INACCESSIBLE ZONE **

TO RErl0VE (A or I)

(Yes or No)

(Yes or No)

U IG41-ISS22 Fuel Pool Cooling Reactor Bldg.

12' A

No No ISS24 38' A

No No ISS30 38' A

No No 12SS32 9'

A No No 12SS33 9'

A No No 15SS37 111' A

No No 20SS76 108' A

No No 19SS79 89' A

No No gy 22SS85 108' A

No No 12SS98 88' A

No No Y

6SSI11 88' A

No No G

7SS121 87' A

No No SSS152 82' A

No No IB32-SSAl Reactor Recirculation Drywel1 8'

I No No SSBl 81' I

No No SSA2 11' I

No No SSB2 11' I

No No SSA3 11' I

No No SSB3 11' I

No No SSA4 21' I

No No SSB4 21' I

No No N'

SSA5 21' I

No No

.SSB5 21' I

No No SSA6 27' I

No No SSB6 27' I

No No w

SSB9A 30' I

No No

TABLE 3.7.5-1 SA.FETY RELATED IIYDRAULIC SNUBBERS

  • E E

lilGli ESPECIALLY 5

SNUBBER ACCESSIBLE OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE ZONE **

TO REMOVE (A or I)

(Yes or No)

(Yes or No)

E M

IB32-SSB9B Reactor Recirculation 30' I

No No SSA10 24' I

No No SSAll 11' I

No No SSB11 11' I

No No SSAl2A 30' I

No No SSA12B 30' I

No No SSB12A 30' I

No No SSB12B 30' I

No No R

IPS-3554 Reactor Vessel Inst.

Drywell 32' 1

No No 3558 32' I

No No 7

3561 32' I

No No E}

3562 60' I

No No 3567 63' I

No No 3570 32' I

No No 3613 32' I

No No 3617A 32' I

No No 3617B 32' I

No No 3751 34' I

No No 3752 34' I

No No IPS-3417 Off Gas System Nirtogen and 31' A

No No Off Gas Bldg.

3418A 33' A

No No 3418B 33' A

No No y

3419A 33' A

No No a

3419B 33' A

No No 3819 37' A

No No LT1 N

TABLE 3.7.5-1 SAFETY RELATED IIYDRAULIC SNUBBERS *

=

E E

lilGli ESPECIALLY SNUBBER ACCESSIBLE OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE ZONE **

TO REMOVE (A or I)

(Yes or No)

(Yes or No)

E M

IB21-2SS3 Reactor Fee <! water Drywell 38' I

No No 2SS4 56' I

No No 3SS6 41' I

No No 3SS9 39' I

No No 3SSil 41' I

No No 3SS12 40' I

No No 3SS13 61' I

No No w

SSS17 38' I

No No 3

SSS18 56' I

No No 6SS20 41' I

No No

-a h

6SS23 39' I

No No 6SS25 41' I

No No 6SS26 40' I

No No 6SS27 63' i

No No ISS227 34' I

No No ISS228 38' I

No No 2SS229 53' I

No No 2SS230 62' I

No No 3SS231 40' I

No No 3SS232 36' I

No No a

3SS233 40' I

No No N ',

3SS234 48' I

No No N-3SS235 63' I

No No 4SS236 34' I

No No 4SS237 38' 1

No No

]

SSS238 53' I

No No u

TABLE 3.7.5-1 SAFETY RELATED llYDRAULIC SNUBBERSA to

o E,

u lilGli ESI'ECIALLY Q

SNUBBER ACCESSIBLE OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE ZONE **

TO REMOVE (A or I)

(Yes or No)

(Yes or No) g U

lH21-SSS239 Reactor Feedwat.er 61' I

No No 6SS240 41' I

No No 6SS241 36' I

No No 6SS242 39' I

No No 6SS243 48' I

No No 6SS244 61' 1

No No R

1 Ell-90SS267 Residual IIcat Removal Drywell 79' I

No No 90SS268 86' I

No No y

90SS271 86' I

No No y

90SS274 93' I

No No 90SS275 93' I

No No 90SS277 96' I

No No 90SS278 96' I

No No 90SS280 101' I

No No 90SS281 93' I

No No 90SS282 101' I

No No 90SS283 93' I

No No 90SS284 101' 1

No No N-90SS285 100' I

No No N *.

ISS302 35' I

No No ISS303 34' 1

No No ISS305 20' I

No No

]'

ISS306 19' I

No No 3

84SS309 33' I

No No 84SS311 35' I

No No 84SS312 35' I

No No

TABI.E 3.7.5-1 m

SAFETY RELATED flYDRAULIC SNUlillERS*

E Si llIGli ESPECIALLY Q

SNUBBER ACCESSIBLE OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE ZONE **

TO REMOVE (A or 1)

(Yes or No)

(Yes or No) g U

IEll-87SS315 Residual lleat Removal 33' I

No No 87SS317 35' i

No No 87SS318 35' I

No No 90SS388 79' 1

No No 90SS389 96' 1

No No 90SS390 96' I

No No 90SS391 93' I

No No 90SS392 99' I

No No

,g 17SS3 Reactor Bldg.

3' A

No No 17SS4

-l' A

No No Y

46SS7 12' A

No No U

46SS9 12' A

No No 56SS13 5'

A No No 56SS15 4'

A No No 20SS19

-3' A

No No 95SS20

-3' A

No No 95SS92 9'

A No No 95SS_.,

9' A

No No 20SS28

-3' A

No No 58SS32 3'

A No No

__.a. '

58SS33

-4' A

No No

.M 58SS35 8'

A No No N

58SS36 8'

A No No A.

18SS40 8'

A No No 18SS47 12' A

Na No 18SS48 13' A

No No g,

LD

)

YTE o

LLV N

LU0 ACt r

1 I I E o

oooooooooooooooooooooooooo CFR NNNNNNNNNNNNNNNNNNNNNNNNNN EF s

PI O e

SDT Y

E

(

)

N o

O N

I l T*

r oooooooooooooooooooooooooo l

CAE o

NNNNNNNNNNNNNNNNNNNNNNNNNN I I N DO s

AZ e

R Y

(

ROEL

)

EB 1

LI BS r

I S o

AAAAAAAAAAAAAAAAAAAAAAAAAA SE SC A

EC

(

CA CN AI

  • SREB N

B O

1 1

'5'81'3 '0 '3 '

'84444' 8

'1 0 3 6 6' 99041 U

I 1 1 '

N T

1 1 - 971 1 1 1 523333333223 S

AV 1

C E

I L

L E

5 U

7 AR 3

DY L

l N

l E

O B

D I

A E

T T

T A

A C

L O

E L

R YTE F

l A

a S

vome R

t t

t E

a T

e S

l Y

l S

lau d

ise R

RE 37 B

BO 045425701 867834578345 UN 9301 51 1 1 89990001 1 1 22222333 N

567791 SS1 1 1 1 22222222222222 S

SSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSS63SSSSSSSSSSSSSSSSSS 81 1 1 71 l l 733330966677777556 622236l 355555844444444999 l

l l

E I

S wbG$Q,

U-ay y6*-

)

YTE o LLV N

LUO ACM r

I I E o

oooooooooooooooooooooooooo CFR NNNNhNNNNNNNNNNNNNNNNNNNNN EF s

PI O e

SDT Y

E

(

)

N o

O N

I

  • l T*

r oooooooooooooooooooooooooo i

GAE o NNNNNNNNNNNNNNNNNNNNNNNNNN I I N I DO s

I AZ e

R Y

(

ROEL

)

EH I

Ll HS r

l S o

AAAAAAAAAAAAAAAAAAAAAAAAAA SE SC A

EC

(

CA CN AI

  • SR E

B N

'22'1 B

O

'2 '2 '0 '1 992'2'2'2'2'2'3'0'2'2'9'3 4'3'31 U

I 1

1 1 N

T 423333444444444454'5'3 S

AV 1

C E

I L

L E

5 U

7 AR 3

DY E

N I

I L

O B

D I

A E

T T

T A

A C

L_

O E

L R

Y_

TE F

l A

a S

vome R

M t

E a

T e

S l

l Y

S lau d

ise R

RE 5734 5

67 i

l O

55666736801 3465978 l

UN 222299222333333533678901 23 N

SSSS2233333333S3SS99990000 S

SSSSSSSSSSSSSSSSSS 33334444 22SSSSSSSSSS8S78SSSSSSSS 1 1 33331 1 777999992922 SSSSSSSS 1 1 1 1 22444444441 41 1 22S2S4S3 1

1 E

I O

- NN*

N.

egEe$Q, gU -

gy y4v n

n i

TAllLE 3. 7.5-1 SAFETY RELATED llYDRAULIC_ SNUBBERS *

o E

h lilGli ESI'ECI ALLY g

SNUBBER ACCESSIHl.E OR RADIATION DIFFICULT NO.

SYSTEM LOCATION ELEVATION INACCESSIBLE 7.ONE**

TO REMOVE (A or I)

(Yes or No)

(Yes or No)

E l1 IEll-6SS404 Residual lleat. Removal

-12' A

No No 8SS405

-14' A

No No 6SS406

-14' A

No No 8SS407

-15' A

No No 12SS408

-14' A

No No ll6SS409

-9' A

No No 113SS410

-9' A

No No 9SS411

-14' A

No No R

109SS412

-14' A

No No 2SS413 0'

A No No Y

132SS414 43' A

No No 20SS415

-4 A

No No 20SS416

-4' A

No No 95SS417 0'

A No No 95SS418

-4' A

No No 45SS422

-2' A

No No 60FS423

-4' A

No No 60SS425

-2' A

No No 127SS426 43' A

No No 128SS427 21' A

No No 128SS428 28' A

No No 128SS429 39' A

No No 128SS430 31' A

No No 128SS431 23' A

No No 127SS433 14' A

No No 127SS434 37' A

No No s

b CM

)

Y. T. V N jo i

l.

l O

i l l ACN r

I I E o

oooooooooooooooooooooooooo CFl NNNNNNNNNNNNNNNNNNNNNNNNNN l

E>

s I' iO e

SDT Y

E

_(

)

N o

o N

i i*

l T*

r oooooooooooooooooooooooooo GAE o

NNNNNNNNNNNNNNNNNNNNNNNNNN N

I I

I DO s I

AZ e t

Y i

(

l t

OliL)

El l

I l i l S r l

iS o AAAAAAAAAAAAAAAAAAAAAAAAAA SE SCA EC(

CA CN AI f-SR E

l l

N l

O

' '0 ' 4775281 1 l

73'3'7777974' U

I 1

l 546666651 73'34'81 N

T 1

1 33 - 3233 1

S AV 1

C EL I

L E

5..

U 7

A l

i 3

D Y

E l

L l

NO D

I l

l A

E T

T T

A A.

C0 l

E I

R YTEF l

A a

S vome t

i j

t fE a

T e

S l

l YS l

au d

i se t

I RE l

9 liO 89007 91 9045678901 2456/6741 l

U N_

6678889900000001 4455 1 1 1

1 1 1 N

444444445555555S55555S5SS5 S

SSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSS5S 0889999i1 6666666668996I I l 4 8888995555544445445SSI $

51 1 l

l E

I JNN#

t@

n_

wmO h p,

U-D #' Y$o

)

Y.T.V N E o I.

l 0t r

l l i ACt 1 I E o

ooooo ooooooooooooooooooooo CFR NNNNNNNNNNNNNNNNNNNNNNNNNN EF s

PI O e SDTY E

(

)

N o

O N

l A-I i T A~

r oooooooooooooooooooooooooo GAE o NNNNNNNNNNNNNNNNNNNNNNNNNN l I N DO s i

t AZ e R

Y(

M O E. )

i l

El I Li l

S r l

iS o

AAAAAAAAAAAAAAAAAAAAAAAAAA SE SC A

EC

(

CA CN AI

  • SR EB NO l

U

'8 '2 '

'3 ' '

'3 ' 466'i.'2'40'0'0'0'544'8'0'41 l

5' I

N T

2371 61 6581 2 - - 41 44474444744 S

AV 1

C E.

I l

L E

5 U

7 A

g R

d 3

D l

Y l

I E

l N

L l

O r

l D

o I

l A

j T

t i

T T

A c

A.

C a

O e

I L

R I

R YTEF 1

A a

S vome R

t t

t r

E a

e T

e S

l ta Y

l W

S la e

u c

d i

i v

s r

e e

R S

RE l

3 29o457 l

o 24356745767 25024502600l l

I l l l

UN 556665777992377 77 8881 1

l I ii N

55555S55555SSSSSSSSSSSSSSS S

SSSSSSSSSSSSSSSSSSSSSSSSSS SSSSS7SSSSS304322020I 33 3 33 48888091 83031 7 7444445577 50 595551 696551 1 1 1 1 1 1 1 1 1 1 1 I 1 1

-W l

S I

E I

I O

D

. wN A "C

w:O h Q,

U-O Y $

n

TAllLE 3. 7.5-1 S_A_FETY ltEl.ATED llVDRAULIC SNUllllERS*

E r2 E

lilGli ESPECIALLY M

SNllllllEll ACCESSillLE OR HADIATION DI FFI Clll.T M

NO.

SYSTEM LOCATION ELEVATION INACCESSlllLE ZONE **

TO REMOVE (A or 1)

(Yes or No)

(Yes or No)

O M

ISW-103SS121 Service Water 38' A

No No 103SS126 60' A

No No 103SS127 57' A

No No 106SS131 60' A

No No 100SS145 59' A

No No 100SSl49 60' A

No No 106SS151 59 A

No No 106SS156 60' A

No No 22 142SS163 60' A

No No 142SStu4 8'

A No No y

142SS165 8'

A No No g

175SS166 42' A

No No 140SS167 42' A

No No 142SS168 58' A

No No 142SSl69 71' A

No No 138SS170 SS' A

No No 140SSl71 58' A

No No 139SS172 58' A

No No 174SSl74 42' A

No No 173SSl75 30' A

No No N til3SSl ?7

-5' A

No No N 100SS193 62' A

No No 139SS209 56' A

No No a 139SS210 56' A

No No g,106SS211 60' A

No No

- 106SS212 60' A

No No

)

YTE o L.LVN l

O l lACN r

E o

oooooooooooooooooooooooooo I I CFR NNNNNNNNNNNNNNNNNNNNNNNNNN EF s

O e

I' I

SDT Y

E

(

)

N o

O N

I liT*

r oooooooooooooooo oooooooooo GAE o NNNNNNNNNNNNNNNNNNNNNNNNNN i

N l I l DO s AZ e Y t

l

(

R O E.

i

)

El l I

Li l

S r

l S

o AAAAI i I i 1 1 1 i1 I I 1 i i1 I i i i1 I 1 i

SE SC A

EC

(

CA CN AI 1-SR E

l N

l l

O i

90'773'4'772'8'8'266'8'8'1 '2'778'7' '8'76 l

i I

N T

561 1 443331 S333 1 4331 1 1 4331 1

S AV C

E 1

L I

L 5

l E

l 7

AR 3

D Y

E l

N L

l O

l B

D I

l A

E T

e T

T A

w A.

C y

O r

l E

L D

R YTE e

F g

A r

S a

hcs i

D M

r E

e f

T t

e S

a i

Y W

l S

e e

l l

c m

iv a

r e

e t

S S

RE 3456 B

lBO 23456891 3467 81 23S6801 2 1 1 1 1 N

222299999990000001 1 1 1 1 1 222 l

N SSSS1 222222222222222 1 1 1 1 1 1 S

SSSSSSSSSSSSSSSSSSSSSSSSSS 6673SSSSSSSSSSSSSSSSSSSSSS 002299999996666668888881 I I 1 1 1 1 1 1 1 1 1 1 1 2222221 1 1 1 1 1 I 1 1 W

1 S

2 1

l sNN# a i

l R* ygS m:!m$p,

U-n E

)

Y.T.V N E o l.

l 0

t l l t

ACt r o

oooooooooooooooooooooooooo i

I I i

CFR NNNNNNNNNNNNNNNNNNNNNNNNNN EF s

I I

O e SHTY E

_(

)

N o

O

_N k

I iTk r oooooooooooooooooooo oooooo l

GAE o

NNNNNNNNNNNNNNNNNNNNNNNNNN N

l I iDO s

f AZ e t

Y i

(

lt O E. )

l E. B 1

t I l

S r

l S

o I i I I 1 I 1 1 I i I I I I I I I I 1 i I i 1 1 iI i

SE SC A

EC

(

CA CN AI

  • SREB N

B.

O 4' 4'3'3'56' 6'2476' '8'0'5'0'786'4'8'0'1 6' 78'9 U.

I N-T 334443334331 21 1 1 1 341 333333 S-A V

C-E.

1 I

l 5

L-E U..

7 A.-

R.

3 D.

Y-E l

L l-N0 D-l 1

l A

E T

T T

A A

C L

0 E

I R

YTE e

F g

A r

S a

hcs i

D ttE f

T e

S i

Y l

S e

R mae t

S R

E l

l o

34568901 6/801 2467 90567901 6 l

l UN 2244445555566666667 7 7 7 7888 N

22222222222222222222222 222 S

SSSSSSSSSSSSSSSSSSSSSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSS I l 3333'l 300000077 7 7788888l 2 i

I l 33333 3 2222222222255555S1 1

2 B

I p

C V.

~.

B t yga

,,O Q, gU -

o

TAltl.E 3.7.5-1 SAFETY REI.ATED llYDRAlli.IC SNilllBERS*

w

n O

ui 11IGil ESPEC I ALI.Y Q

SNUllllEll ACCESSillt.E Olt RADIATION DI FFIClli.T NO.

SYSTEM LOCATION EI.EVATION INACCESSIBI.E ZONE **

TO REMOVE (Yes or No)

(A or I)

(Yes or No)

U 1112 l-12SS287 Steam He1ief Discliarge 39' i

No No 12SS288 44' I

No No 12SS289 39' I

No No 12SS290 43' 1

No No 34SS296 35' I

No No 34SS297 35' 1

No No t'

34SS298 44' I

No No 34SS299 39' I

No No y

34SS300 44' I

No No g

26SS302 11' i

No No o

26SS303 5'

I No No 58SS304 10' I

No No 58SS305 5'

1 No No 58SS306 15' i

No No 58SS307 16' i

No No 12SS308 28' i

No No 12SS309 29' I

No No 12SS310 17' i

No No 12SS311 11' I

No No 12SS312 11' 1

No No llSS313 16' I

No No IISS314 11' I

No No IISS315 7'

I No No N

19SS316 11' I

No No 19SS317 17' I

No No 18SS318 11*

I No No P

)

Y.T.V N E o l.

l O

l l t ACM rE o ooooooooooooooo o I I CF1 NNNNNNNNNNNNNNNN EF s

PiO e SDTY 1

E

(

5

.h

)

7 t e e

N o

.i s h

O N

3 wn t

i i*

l T*

r oooooooooooooooo e

GAE o

NNNNNNNNNNNNNNNN eec o

l ci t

l H N l

i l

O s

b nL AZ e

aa d

R Y

Td t e

r x t

(

ooe t

t cn i

c m

R t ae b

OE n

h u

e nt s

L

)

mi E.

l l

I d

h e

i i l

S r

ad t b

l S

o I I I i I I I I 1 I I I i i 1 i eei I

SE md w l

SC A

Ai l

EC

(

vd a

CA eoe i

CN s rd ts AI npu e

l s

cec a

S

i. rn e

R I ai ra E.

N rgs i

oni n

O l

'0 '1 4'56'846' 978'8'1 l

'1 ii o

U I

1 1 33334271 221 1 1 7 rt1 i

N T

S A

pr -

t V

o5 a

1 C

E t p i

l.

L ue7 d

E or a

S I

U h

3 r

7 A

t d R

i ne h.

3 D

wal gt Y

b i s L

l N

s na h e E

l O

mot u

D I

ei nq ll A

E T

t t o i e T

T A

s at r

A.

C yt s

O s nn et l

E L

eo gn R

d ni ne u

eis am Y

t ci hd T

aov cn E

e l d e e

F g

e r

om A

r r,

t A S

a sd h

yne ee c

t os us s

eio d n i

f t p e

D aao ec M

s ur l

i.

E f

l p b1 T

e oa a

S i

t va t t Y

l e

x S

e d

t s e R

e ya i n d th h

m d et.

t e a

af t

h e

ad s ot t

es ne t

S b

au f

t q

s o ya9 e n

ah5 r ot mt i r 0t t a sd5 n ap R

re e

c E

edi m i s t

l biFd f a iHO 9056790234567890 b vC n i

222223333333334 uo e

dC l

1 iN N

3333333333333333 nr0 m oi t

S SSSSSSSSSSSSSSSS S p1 A MN S3SSSSSSSSSSSSSS 0999999333344444 255555533333333 3 1

2 l

i t

hD

~

+

- CL M#' Y$"

'FLAtlT SYSTEMS 3/4.7.3 HYORAULIC SilUBBERS LIMITING C0i10lTI0tl FOR OPERATI0tl 3./.5 All hydraulic snubbers shown in Table 3.7.5-1 shall be CPERABLE.

APPLICABILITY:

CCfl0ITI0tl5 1, 2 and 3 ACTI0ft:

With one or more hydraulic snubbers inoperable, restore the inoperable snub br(s) to OPERABLE status within 72 nours or be in at least HOT SHUTCOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in LOLD SHUTDOWtl witnin the tollowing 24 nours.

SURVEILLANCE REGUIREMENTS 4.7.5.1 Hydraulic snubbers snown in Tacle 3.7.5-1 snall be cemonstrated OPERABLE by the performance of the following augmented inservice inspec-tion program and the requirements of Specification 4.0.5.

4.7.3.2 Each hydraulic snubber with seal material fabricated from ethylene propylene or other materials demonstrated compatible with the operating environment and approved as such by the NRC, shall be deter-mined OPERABLE at least once after not less than 4 months but within 6 months of initial criticality and in accordance with the inspection schedule of Table 4.7.3-1 thereaf ter, by a visual inspection of the snubber or functional operability test.

Visual inspections of the

{

snubbers shall include, but are not necessarily limited to. inspection of the hydraulic fluid reservoirs, fluid connections, and linkage con-nections to the piping and anchers.

Initiation of the Table 4.7.3-1 inspection schedule shall be made assuming the unit was previously at the 6 month inspection interval.

4.7.5.3 t.ach hydraulic snubber with seal material not *abricated from ethylene propylene or other materials demonstrated compatible with the acerating environment shall be determined OPERABLE at least once per 31 days by a visual inspection of the snubcer.

Visual inspections of the snubbers shall include, cut are not necessarily limited to, inspection of the hydraulic tluic reservoirs, fluid connections, and linkage connections to the piping and anchors.

BRUNSWICK - UNIT 2 3/J 7-9 j//$

j66

os TABl.E 3.7.5-1

o SAFETY REl.ATLI) IlYDRAUI.lC SNUllllERS*

m N

IliGil ESPECI AI.I.Y SNililllER ACCESSIHl.E OR RADIATION DI FFI Cllt.T h

No.

SYSTEM LOCATION ELEVATION INACCESS illt.E ZONE **

TO REMOVE H

(A or I)

(Yes or No)

(Yes or No) to 2E21-2SS16 Core Spray Reactor lililg.

O' A

No No 2SSl7 13' A

No No 2SS18 14' A

No No 15SSl9

-3' A

No No 15SS20

-3' A

No No 28SS23

-4' A

No No 2SS31 68' A

No No 2SS32 66' A

No No gg 6SS41 70' A

No No 6SS42 69' A

No No y

1 26SS91

-6' A

No No 25SS96

-6' A

No No e--

40SS106

-12' A

No No 40SS107

-12' A

No No 39SS10ll

-12' A

No No 39SS109

-12' A

No No 2E21-3SS46 Drywell 63' I

No No 3SS47 63' i

No No 3SS48 65' i

No No 3SS49 66' 1

No No 7SS53 63' i

No No 7SSS4 63' I

No No 7SSSS 65' I

No No N 1 N.4 N

)

Y T. V N E

o L.

l i

O I l ACM r

I I E o

ooooooooooooooooooooooooao CFR NNNNNNNNNNNNNNNNNNNNNNNNNN EF s

PI O e SDTY E

(

)

N o

O N

I I

T*

r oooooooooooooooc, oooooo oooo l

GAE o

NNNNNNNNNNNNNNNNNNNNNNNNNN l I N l

DO s

i AZ e R

Y

(

R O E.

l

)

E. B 1

I I BS r

AAA I S o

I 1 I I I I i I I I 1 I i I 1 iiI I i i iI SE SC A

EC

(

CA CN AI ASRE B

N B

O 64'96' 8 '1 '8'344'98'9O'2'2'2'0'50'7 '0'0'74'5 U

I N

T 65221 32222666/7 77434343 -

S AV 1

C E

I L

5 L

E U

7 A

g R

d 3

D l

Y l

I E

N l

l L

O l l l

l r

B D

I ll l

l o

A E

T ee e

e t

T T

A ww w

w c

A C

yy y

y a

L O

r r r

r e

E L

DD D

D R

H Y

T j

E n

F p

I A

us S

ny t

aS n

e e

a l n v

l Ci i

o a

r o

i rr D

C lE eD T

t d

S ya e o

s Y

aWt R

s S

r a

e pr s l

r S on o

P t e r

ecd t

i l

r a n n

g oeo o

i CRC C

i l

R E

l l

l O

35691 358 l

l iN 00001 1 l l 0l ?

5 N

6 1 1 1 1 1 I iiI 6781 i l 45790I 91 S

53SSSSSSSSSSSSSSS44445S5SS SSSSSSSSSSSSSSSSSSSSSSSSSS SS1 I I 00I 6666666 SSSSSSS00 I I 5SS555SS1 1 1 1 1 1 1 444444262 7 I 1 1 1 2

1 1

232 1

4 4

EGB C

E E

222 2

2 2

- NNc O

rea C

no i

e:EuN A a m} y1w

)

Y. T. V N E o

i. luO l

ACN r

E o

ooooooooooooooooooooooo ooo I I CFl NNNNNNNNNNNNNNNNNNNNNNNNNN t

EF s

PI O e

SDTY E

(

)

N o

O N

I !-

iT!

r oooooooooooooooo o oooooo ooo l

GAE o

NNNNNNNNNNNNNNNNNNNNNNNNNN N

l I DO s i

l AZ e t

Y l

(

R O E.

l

)

E. H I

I l DS r

I S o

AAAAAAAAAAAAAAAAAA4AAAAAAA SE SC A

EC

(

CA CN AI iS l

l E

i N

B O

'S '0 'l '241

'2'774422'72'2'3 U

I I l 5l l l 4l l

N T

- - - - - - 331 1 1 21 44 -

S AV

_ c E.

1_

l.

l E

5. _

t l

l 7

A l

3 i

l l

Y E.

l N

l 0

t D

l 1

l A

E T

T T

A A.

C0 l

E 1

R Y

T j

E n

F I

A S

tna l

oo H

C ET S

s Y

s S

er P

i lg i

i l

f lE l

l O 01 23 t

li i N 2

1 236746890000 N

7dl 333?,7802$477777 2356 88991 1 1 1 S

2 2 3' 3344S6SSSSSSSSSSSSS SSSSSSSS3SSSSSSSSSSSSSSSSS SSSSSSSS$SS0S1 1 1 1 1 4441 1 009 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 2 2 4 4

'e 66661 1

4E s

2 ye 4

w,E R

hHe mg y8,u 4

)

YTE o L.LVN UO l

ACH r

I I E o

oooooooooooooooooooooooooo CFi NNNNNNNNNNNNNNNNNNNNNNNNNN t

EF s

PI O e SDTY E

(

)

N o

O H

iTMr oooooooooooo>- oooooooooo ooo I

l GAE o NNNNNNNNNNNN 4NNNNNNNNNNNNN l I N l DO s i

AZ e t

Y I

(

11 0E L

)

El 1

l Li l

l S

r iAAAAAAAAAA iS o

AAAAA1 iI I i 1 I I I I SE SCA EC(

CA CN AI f-S R

E l

N t

'44'0'3 i

O 0

721 1

'7 6' '8'958'8'048888

'21 90000'9004' l

l I

1 1 i

99983544664834 N

T 1

- - - 61 1 1 1 91 1 S

AV C

E 1

I L

L 5

l E

l 7

A g

g R

d d

3 O

l l

l Y

B I

L l

N E

l O

rl r

D I

ol o

l lA E

T t e t

T T

A cw c

A.

C ay a

O er e

l E

L RD t

I l

l

.r Y

T j

t E

n W

I t

FA n

S t

e l

n mg o

a t n o

l ai C

o es o

r n C

T e d

1 3

S s

lT s

i S

s at C

Y s

G n S

e e

r ym g

P l

u d

i d r l

l nt i

lg as i

t n x

l t

i SI I

R E

747901 257894 B

BO 81 66677777778 034526845 UN 4567S1 1 1 1 1 1 1 1 1 1 1 I N

0001 SSSSSSSSSSSSI 3334S557 7 S8SSSSSSSSSSSSSSSSSSSSS S

1 1 1 SSSS3SSSSS SSSSTl l l l l l l l l l l i3S2G00000000000820022OI 77 22S7777777777753553:

1 l S1 1

21 C

4 2

C 1

t E

2 2

12 1

~

, NNA

.N A i

a i

IAE!I5_3 _7 5-I (5

f w

SAFETY 1(El.ATEI) IlYl)RAlli.lc SNultitEliS!4 n

ll1Cil ESPECI Al.l.Y SNiliti!Ett ACCESSiltl.E OP RAl)lATION lil FF I Clit.T h

NO.

SYSTEM l.0 CATION Ei.EVATION I NACCESS illi.E ZONIN!

10 l<EllOVE H

(A or 1)

(Yes or No)

(Yes or No) ra 21<CC-17SS76 Rx. Is i dg. Clsil. Cool Wtr.

39' A

No No

.16SS78 54' A

No No 37SS79 54' A

No No 39SS80 59' A

No No 38SS81 54' A

No No 34SS82 57' A

No No 35SS83 57' A

No No 6SS107 60' A

No No g

7SSil2 57' A

No No 47SS167 59' A

No No y

4 47SS168 58' A

No No u

48SS169 60' A

No No 2ltCC-60SS121 Drywell 17' i

No No 60SS122 16' I

No No 65SS128 7'

I No No 65SS129 7'

i No No llSSl19 9'

I No No 73SS145 5'

1 No No 19SSl57 21' i

No No 19SS160 29' i

No No j/ l'SN-A2SS'10 l*rimary Steam Drywell 65' I

No No N

A2SS11 64' i

No No N,

AISS32 40' i

No No A

A3SS11 35' i

No No A3SS34 35' i

No No 9

n

. i

.a : e

_:a>z

_: = c.

<u=iu

- - x; e=ceee==ce: : : = cec eec : : :

v a z-zzz==zzzzzzzzzzz=zzzzzzzzz x-s

. - c ' x:.

z = i- >-

Z

w

.c...i :

z z

=i-- : -

ee: eoeeeeec ee ec eeec c<we zzzz==zzzzz=zz=zzzzzzzzzzz z.

= = c'a

< s t cs l>

w I

0 :.d i w =1w

.i

= zi u

- z; z w' z v[<

w vi-u <i u zi

< -i z

= _. _,

=,

zi al

=

-Neace=xe=xNme=cexemxNcece

=

~

Z.

H 4NCC4M4MM<-Nec4M<MMM-Nccom zi vi

.e,

a; i.

-1

e.,t w

n.

m

=

i

>i zl e,

=

a' c

=;

=l

'-l s

zI H

ui

I OI As Jl zi, i-i

-e.

a, m

=

S L"*

i=

0 z

>l z

e L

=

+-u

=

Z i

=.,

= =<

= z:

ex=-Nmaenx=-ceen==-Naex

=-

accaccacecreece: :cece: ~ ~

z I

zz=zzzzzzzzzzzzzzzzzzzzzzz.

z z z z z z z z z z z z z z z z z z r z :: z e v: zz men Nm? m

  • m m e e. N N m *." m ? m e e N N m~

<<==========uuuuuu uuu====

t Z

U; i*.

g 1774 172 BRUNSWICK - UNIT 2 3/4 7-16

TA. lll.I'. 3 7. 5 1 en Oy sal'ETY_ !!El.A.TED llYl]RAlli.lC SNtjllllERSf 5x lilGli ESPEC I Al.l.Y SNUllllER ACCESSilli.E OR HAl)lATION D I FF I Ctll.T NO.

SYSTEH 1.0 CAT 10N El.EVATION I NACCESS illi.E ZONE:' '

TO ret 10VE H

(A or I)

(Yes or No)

(Yes or No) w 2PSN-D3SS72 Primary Steam 35' I

No No I)3SS73 41' I

No No DSSS76 22' i

No No 2E51-4SS45 RCIC Drywel1 31' i

No No 3SS46 39' I

No No 3SS47 39' i

No No 4SS66 39' I

No No 4SS100 40' i

No No w) 4SS101 40' I

No No 4SS102 39' I

No No y

,8.

4SS103 36' I

No No 4SS104 31' l

No No 4SS105 30' 1

No No 2F.51-41SS51 Reactor Illalg.

40' A

No No 42SS74 20' A

No No 42SS75 20' A

No No 42SS 7(>

18' A

No No 42SS77 5'

A No No 42SS78 0

A No No 42SS79 4'

A No No 42SS80

-13' A

No No 42SSHI

-16' A

No No 42hS82

-9' A

No No y

40SS83

-9' A

No No 40SS84

-9' A

No No 40SSil5

-12' A

No No N

U

'llAlli.E 3. 7. S-1 en

o 0;

SAFETY RE.l.ATED llYDRAlli.lC SNillittER_S?

u g

o" M

IllGli ESPEC I Al.l.Y SNililitER ACCESSilli.E OR RADIATION D I FF I Clll.T b

NO.

SYSTEtt I.0 CATION El.EVATION I NACCESS illi.E ZONE?*

TO REtlOVE H

(A or I)

(Yes or No)

(Yes or No) w 2E51-40SS86 HCIC

-15' A

No No 40SS87

-15' A

No No 40SS88

-13' A

No No 4 iSti89 41' A

No No 16SS9I

-6' A

No No I7SS94

-6' A

No No 4iSS95 41' A

No No 19SSil3

-17' A

No No

-T 19SSil4

-16' A

No No 49SS129 0

A No No Y

21121-44SSl29 Nuclear Steam Vent Drywell 104' i

No No E

44SSl31 93' i

No No 44SS134 99' I

No No 44SS136 97' I

No No 44SS13/

96' i

No No 44SS138 "5'

I No No 44SS141 8/'

I No No 44SS142 87' 1

No No 44SS143 87' I

No No 44SS146 87' I

No No

'46SS141 82' I

No No

~~""

44SS149 85' 1

No No 44SS150 83' i

No No y

47SS155 75' I

No No a

47SS156 78' l

No No 47SS157 75' i

No No N

A

TAlli.E 3. 7. 5-1 SAlil.TY ltEl.ATEI) IlYDRAlli.lC SNtillllERSC 111G11 ESl'ECI Al.l.Y SNtilillER ACCESSilli.E OR RADIATION

1) l l'I'I Clli.T N 0 '.

SYSTEM l.0 CAT l0N El.EVATION I NACCESS illi.E ZONU '

TO ItEtl0VE (A or I)

(Yes or No)

(Yes or No) 2C41-9SS4 Stamtl>y I.iqui<l Cont rol Drywell 63' I

No No 9SSS 47' 1

No No 9SS8 42' I

No No 9SS10 38' I

No No 9SSil 39' i

No No 9SS12 69' I

No No 9SS13 52' i

No No 2C41-9SS26 lleactor liliig.

72' A

No No 9SS27 72' A

No No 9SS34 84' A

No No 2G41-ISS22 I?ne l l'ool Cool i ng iteactor Ill<lg.

12' A

No No ISS24 38' A

No No ISS30 38' A

No No 12SS32 9'

A No No 17SS13 9'

A No No 1$SS37 111' A

No No 11SS54 88' A

No No 10SS67 89' A

No No 20SS76 108' A

No No iISS79 89' A

No No 22SS85 108' A

No No 12SS98 88' A

No No bSSIi1 88' A

No No g

/5S121 87' A

No No SSSl52 82' A

No No 4-59SSl59 84' A

No No N

LD

)

Y. T. V N E o 1 li O 1ACM r l

I I E o oooooooooo ooooooooooooooo o Cl R NNNNNNNNNNNNNNNNNNNNNNNNNN E

'l s

oe I'

I SDTY E

(

)

N o

O N

I iT!

r ooooooooooooooooooooooooo o l

GAE o NNNNNNNNNNNNNNNNNNNNNNNNNN N

1 1 1

DO s 1

AZ e R

Y

(

R O E. )

t E.

l l

(

l i l

S r I

S o I I i I I I i I I i I iiiI I i I I iI I iI I i I

SE SC A

EC

(

CA CN AI

'S'.

t l

E l

l N

l O

'0 '0 4 1 ' '0 '0 '0 '0 '3 '8 '0 '0 '5 i-ll 1 1 77 I

1 1 1 1 1 1 N

T

'8'81 S-22222233 21 4333 366666 1

1 A

V I_

C E.

1, l

5. __ i E

l l

7_

A R

3_

l N

D Y

E. _

l-t.

0 I

l l

D 1

l l

lA.

E.

T e

e T.

T-A w

w A..

C y

y 0

r r

l.

R-1 D

D E-Y.

TE-n l-A.

o S-.

i t

t s

a n

i I

ue l

N r

e E

i s

T c

s S

e e

Y R

V S

r r

o o

t t

c c

a a

e e

R R

R l

l l

l l

O l

l 1

l iN A1 Ai N

A1 0l 1

I 2222 l i 223344S5b6991 l l l 1 1 l

481 27 S

AiAiAhAiAiAiiBAAiAABi55666 l

l l

l l

l l

l SSSSSSSSSSSSSSSSSSS;S55555 J

SSSSSSSSSSSSSSSSSSSFS331 3 3 2

S 3

P 1

2 1

2 aNNM

~C h

e, Nr., h H w yy yL,o n

TAltl.E 3.7.5-I m

o h

SAFF/lY l<iil.ATED llYl)RAlli.l.C SNllilllERS2 x:

n 111G11 ESPECI Al.l.Y SNllllllER ACCESSilli.E OR RAlll ATION D I FF I Clll.T h

NO.

SYSTEM l.OCATION E1.EVATION I NACCESS illi.E ZO N F.'* '

TO Ithtl0VE H

(A or I)

(Yes or No)

(Yes or No) u 21'S-3570 Reactor Vessel Inst, 65' i

No No 3613 90' I

No No 3705A 32' 1

No No 370511 32' i

No No 3706 32' i

No No 1707 32' 1

No No 370ft 32' 1

No No 3709 32' 1

No No g

3710 32' I

No No 3722A 82' 1

No No 4

372211 82' i

No No 21'S-3417 Off Gas System Nitrogen anil 31' A

No No 01i Gas ill elg.

3418A 33' A

No No 341811 33' A

No No 3419A 33' A

No No 341911 33' A

No No 3423 3/'

A No No 21121-2SS3 lleact or l'eedwate r I)rywell 38' 1

No No 2SS4 56' i

No No 3SSb 41' i

No No 3SS9 39' 1

No No 3SSil 41' i

No No y

3SS12 40' i

No No N

3SSI1 61' I

No No 4m=

SSSI7-

'18 '

i No No 4

N

T. Alli.E.3. 7. 5.1 to

@l SAF..ETY REl.A.TE.I_)._I_lY.D.it.Alli. I C...S._N.!llil.l.ER. _S.a..

u g

5x 11iGli ESl'ECI A1.1.Y i

SNllilllER ACCESSlill.E OR ltADIATION D I FFI Cill.T 1.0CA_ T 10N El.EVAT10N

_I N ACCESS I lli.E ZON E-! '

To l(Et10VE NO.

SYSTEtt y,

,z.,;,7,,,,

y,,

w 2tl21-SSS18 Itea c t o r l'ee<!wa t e r 56' I

No No 6SS20 41' I

No No 6SS23 39' 1

No No 6SS25 41' I

No No 6SS26 40' I

No No 6SS27 63' i

No No ISS227 34' 1

No No 1SS228 38' I

No No wp 2SS229 53' i

No No 2SS230 62' I

No No y

L 3SS231 40' I

No No N

3SS232 36' 1

No No 3SS233 40' I

No No 3SS234 48' I

No No 3SS235 63' i

No No 4SS236 34' I

No No 4SS237 38' I

No No SSS238 53' i

No No SSS239 61' I

No No 6SS240 41' I

No No 6SS241 36' I

No No bSS242 39' I

No No 6SS243 q, -

48' i

No No 6SS244 q.

61' I

No No 2 Ell '10SS767 a'

Ites iilua l llea t Itemova l Drywell 79' I

No No 90SS268 86' i

No No CO

A

> h" W ' O

  • W >.Z

- e#

W g

_l..

- - W O O O O O O O O O O O O O O O O O O O O $ 0 0 0 0 0 0 1 %'

ZZZZZZZZZZZZZZZZZZZZZZZZZZ WW Z

7.,,,

O a a, Z ll'

!= t >

W

.s A

Z O

'Z A.

.A

.A O

A.,

dh M

A.

O.l.

Ah A

d4 A.

A.h A.

A db

.A

.A 4

f'.h d'%

  1. 4 AI.b I

M M

Z,,

- w

/e

. < NI" w

NO Wl E $ l "".

c. *A 1.

-4 0

=

= -

'A W Z Ui<

.r.: :;

U <jv U Z;'

< -1

  • .y..

1W-O' 2j

=,

e

.-e.

=i emeee=~=mOOreOemermffeeeme

=-

si

C e e e e - e - e - - m m N - m m m m m m N eeee 00 i

-i U,

W, e8 t

q/* I WI

.s,: l
l i

N-.!

--:= '

e Zl W

=l

.=.e

n. e

.u

?'

r d'

UI W;

Of W+

W' X'

>f i- '

Wl L

c L^

0$

=~*

-+

M h

N H.f4.

0 j

l ZI c

0

  1. M O

M Z

C Ol

< fN C O = N m < f.

7 = %

U"' N CCC 7 O - N n

O Z.

NN N N N cc :C :C :C X :C N m c e O - - - - - <C oC O O O Z

NNNNNNNNNN N O O O O m :""' ** *^ :"" :"* m m m m m Z

AZZ"AZ'A Z *4 *A Z Z M M m m C/", *AZZZZZZZZ"A Z :/: U: U: AU

  • A Z "A r4 *A U: Z L*: u: Z Z 00 :.C

.O A Z ' 4 Z Z A

OOCOOOOOOOOZZZZ<<<N N N O&C@ O O O O & & O - - - = CC :C :C :C CC"oc : O e ? O I

s.m N

1774 179 BRUNSWICK - UNIT 2 3/4 7-23

TAlli.E 3. 7. 5-1 g

SAFETY _ It F. I.AT E D _l__lV_DR A. U I. l C_S_N U lillE_llS_?

5 7:

IllGli F.SI'F.C I Al.l.Y SNtlllllER ACCESSilli.E Olt RAlll ATION D I FFI Clli.T h

NO.

SYSTEM I.0 CATION El.EVATION INACCESSillLE ZONE *?

TO ltEtl0VE H

(A or I)

(Yer, or No)

(Yes or No) w 2 Ell-17SS3 ltesiilua l lleat Removal Reactor Illdg.

-3' A

No No I/SS4

-1' A

No No 46SS7 12' A

No No 46SS9 12' A

No No 56SS13 5'

A No No 56SS15 4'

A No No 20SS19

-3' A

No No 95SS20

-3' A

No No m}

95SS22 9'

A No No 95SS23 9'

A No No y

L 20SS28

-3' A

No No o

58SS32 3'

A No No 58SS33

-4' A

No No 58SS35 8'

A No No 58SS 16 8'

A No No 18SS40 8'

A No No 18SS47 12' A

No No 18SS4B 13' A

No No 68SS59 15' A

No No 21SS63 8'

A No No 21SS70 13' A

No No 21SS71 10' A

No No 37SS95

-3' A

No No

. 61SSilo 6'

A No No N

ll6SSl43

-11' A

No No N

ll3SSl57

-11' A

No No N

~

CD.

t,o T. Altl.E _3. 7. 5-1 0

SAF1 TY _ItE1.A_TFD llYl}RAlli.lC SNilllill](Sj y

I tilGil ESPEC I Al.l.Y Q

SNilllllElf ACCESSilli.E OR 1(ADIAT10N o. I i:'lll.T y

NO.

SYSTEtt 1.0 CAT 10N El.EVATION I NACCESS illi.E

/.ONE1

  • TO ltEll0VE (A or 1)

(Yes or No)

(Yes or No) g 2 Ell-71SS174 Resiilual lleat Removal i<eactor lililg.

-17' A

No No 71SSl76 9'

A No No 37SS184 9'

A No No 53SS192 18' A

No No 53SS195 41' A

No No 53SS191 14' A

No No 53SS200 14' A

No No u

50SS201 14' A

F-No S

89SS208 5'

A No No u

46SS21(i 28' A

No No b

46SS217 31' A

No No 46SS218 30' A

No No 47SS223 33' A

No No 47SS224 36' A

No No 47SS225 36' A

No No 47SS227 39' A

No No 47SS228 39' A

No No 95SS233 20' A

No No 9'3SS234 24' A

No No 95SS235 31' A

No No 131SS255 42' A

No No 131SS257 22' A

No No 132SS263 30' A

No No CO' 132SS764 31' A

No No

~*

t-2lSS296 19 '

A No No 21SS29/

39' A

No No

y TAllI.E 3. 7. 5 - l_

h SAFETY REl.ATEI)_IlYl)RAlli,lc SNiillllliRS*

N O

ll1 Gli ESI'EC I A1.1.Y SNililllER ACCESSilll.E OR RAl)lATION D I FF I Clll/I' h

NO.

SYSTEM l.0 CAT 10N El.EVATION I NACCESS illl.E ZONE **

TO REtlOVE H

(A or 1)

(Yes or No)

(Yes or No) o 2 Ell-47SS323 Resioloal lleat Removal Reactor Bldg.

42' A

No No 47SS326 42' A

No No 47SS328 42' A

No No 49SS330 42' A

No No 49SS331 42' A

No No 49SS333 42' A

No No 49SS334 43' A

No No 49SS336 40' A

No No s

128SS355 42' A

No No 49SS359 42' A

No No

[

35SS360

-8' A

No No e

35SS361

-16' A

No No 127SS176 59' A

No No 128SS.187 43' A

No No 71SS393 9'

A No No 2SS396 5'

A No No 2SS397

-3' A

No No SSS:198

-4' A

No No 2SS399

-3' A

No No SSS400

-3' A

No No N

4SS401

-12' A

No No N

SSS402

-12' A

No No

ISS403

-11' A

No No 6SS404

-12' A

No No CD HSS405

-14' A

No No N*

TAlli.E 3. 7. 5-l_

en E

d S Al'ET'. REl.ATEI) IlYl)RAlli.lC SNilllllERSfi I!

N 11iGil l'.Sl'EC1 A1.1.Y SNUllllER ACCESSiltl.E OR RAlll ATION DI FFIClli.T h

No.

SYSTEM l.0 CATION EI.EVATION I NACCESS illi.E 7.ON Ef '-

TO REMOVE H

(A or I)

(Yes or No)

(Yes or No) w 2 Ell-6SS406 Residual lleat Removal Reactor Hliig.

-14' A

No No HSS407

-15' A

No No 12SS40ft

-14' A

No No ll6SS409

-9' A

No No 113SS410 17' A

No No 9SS411

-14' A

No No 109SS412

-14' A

No No 2SS413

-14' A

No No y

132SS414 0'

A No No 20SS415

-4' A

No No Y

20SS416

-4' A

No No U

95SS417 0'

A No No 95SS418

-4' A

No No 45SS422

-2' A

No No 60SS423 4'

A No No 60SS425

-2' A

No No 127SS426 43' A

No No 128SS427 21' A

No No 128SS428 28' A

No No 128SS429 39' A

No No

~

N 128SS430 31' A

No No N

128SS431 23' A

No No 127SS433 14' A

No No 1273S4'14 37' A

No No Oo 12 /SS4'l's 15' A

No No u

60SS4'll 13' A

No No

TAltl.E _3. 7. 5-1 to

u h

S A FETY __R_E l.ATED _ll_VDR_A_U_ _I. l C_.S N lllillE RS.f'_

N 7:

111Gil ESl'EC i A1.1.Y SNlllillER ACCESSilll.E OR RAlll ATION lil FF ICllt.T h

NO.

SYSTEll I.OCATION El.EVATION I NACCESS illi.E ZONEf '-

TO REMOVE H

(A or I)

(Yes or No)

(Yes or No) to 2 Ell-60SS438 Residual lleat 1:emoval Reactor Bldg.

12' A

No No 60SS440 13' A

No No 65SS441 3'

A No No 6SSS442 3'

A No No 60SS443 11' A

No No 73SS444 2'

A No No 21SS445 S'

A No No u

83SS44(>

10' A

No No S

68SS446 13' A

No No u

75SS449 2'

A No No h

61SS450 7'

A No No 60SS451 13' A

No No 60SS452 13' A

No No 60SS453 10' A

No No 60SS454 10' A

No No 89SS459 11' A

No No 89SS460 10' A

No Nu 89SS461 6'

A No No S3SS462 15' A

No No y

53SS463 14' A

No No a

53SS464 14' A

No No 53SS465 14' A

No No G

53SS466 14' A

No No SOSS467 14' A

No No 50SS468 17' A

No No 18SS469 53' A

No No

TA_lt l_.E _ 3_. 7, 5 - 1 us g,

E u>

SAFETY ltEl.ATED llYDitAlll.lO SNilllllEllS?

s.

$n ll1Gil ESI'EC I AI.l.Y SNtillllElf ACCESSIIll.E Olt itA111 ATION DI FF I CllIll' NO.

SYSTEtt 1.0 CAT 10N El.EVATION I NACCESS illi.E ZONIF' To itErlOVE H

(A or I)

(Yes or No)

(Yes or No) w 2 Ell-18SS470 Itesielua l lleat itemova l iteact.or Illilg.

43' A

No No 89SS480 67' A

No No 89SS487 67' A

No No 89SS489 f.7 '

A No No 89SS491 67' A

No No 91SS499 69' A

No No 9tSS500 57' A

No No 56SS504 14' A

No No uy 56SS505 7'

A No No 56SS506 3'

A No No y

6 56SS507 3'

A No No 56SS508 4'

A No No 46SS509 8'

A No No 46SS510 11' A

No No 46SSS11 10' A

No No 46SS512

-1' A

No No 58SS514 14' A

No No N

49SS515 37' A

No No N

49SS516 37' A

No No 56SS517

-5' A

No No SISS546 32' A

No No

]

SISS547 28' A

No No Il5SSS49 31' A

No No w

54SS551 31' A

No No 54SS552 28' A

No No 9!!SS554 32' A

No No

TAlli.E 3.1.5-I u,

o SAFETY REI.ATED llYl)RAlli.lc SNililllERS*

s R

lilGli ESPECI Al.l.Y SNilllllER ACCESSilli.E OR NADIATION DI FF I Clli.T h

NO.

SYSTEH 1.0 Carl 0N El.EVATION I NACCESS I Bl.E ZONEA*

TO I(EtlOVE O

(A or I)

(Yes or No)

(Yes or No) w 2 Ell-58SS563 Residual lleat Removal lleactor Illelg.

7' A

No No 58SS565 13' A

No No 58SS566 6'

A No No 101SS5/3 15' A

No No 69SS574 6'

A No No 91SS575 53' A

No No 68SS577 8'

A No No gp 53SS596 14' A

No No 50SS597 20' A

No No y

3 2SW-133SS22 Service Water Reactor Illdg.

-6' A

No No o

110SS35

-5' A

No No 174SS70 42' A

No No 173SS72 14' A

No No 142SS14 40' A

No No 142SS75 40' A

No No 14()SS80 40' A

No Ne 142SS82 7(l' A

No No 140SS86 45' A

No No 153SS102 44' A

No No N

153SS109 44' A

No No 173SSilu 48' A

No No 173SSI14 70' A

No No 153SSil5 44' A

No No CD 103SSill 41' A

No No O

103SS121 38' A

No No

T. AllI.E.-'_t 7. 5-1 tom A

sal?ETY. RE.l.A._T.ED ll.VD..itAU_l.1. C SNill.lllERS!'

v3g 5

7:

111Gil F.Sl'EC1 A1.1.Y SNilititER ACCESSilli.E OR ltADIATION 1)IFI'ICill.T NO.

SYSTEM l.0 CATION El,EVATION I NACCESS illt.E ZONEf*

TO Rett 0VE H

(A or 1)

(Yes, or No)

(Yes or No) w 2SW-103SSI26 Service Water Reactor lililg.

6C' A

No No 103SS127 57' A

No No 106SS131 60' A

No No 100SSl45 59' A

No No IOOSS149 60' A

No No 106SS151 59' A

No No 106SS156 50' A

No No 142SS163 56' A

No No ay 142SS164 8'

A No No 142SS165 8'

A No No y

175SS166 56' A

No No 140SS167 42' A

No No

~

i42SS168 71' A

No No 142SS169 7l' A

No No 138SS170 55' A

No No 140SSI/I Sil '

A No No 139SS172 58' A

No No 109SS173 14' A

No No 174SSI74 43' A

No No y

I73SS175 30' A

No No 133SSI76 14' A

No No N i A-133SSl77

-5' A

No No 100SS193 62' A

No No

~.

139SS209 56' A

No No 138SS210 56' A

No No I()6SSZ l I 60' A

No No

TAlli.E 3. 7. S-1 9p SAFI'TY REl.ATED llYDRAULIC SNililllEl:S4 M

7:

11IGil ESl'EC I Al.I.Y SNUllllER ACCESSIHl.E OR RADIATION D ilT I Cill.T g

e-1

~ ~ ~

SYSTEll 1.OCATION ELEVATION I N ACCESS illt.E ZONIO !

TO ret lOVE NO.

-~

(A or l}

(Yes or No)

(Yes or No) 2SW-106SS212 Service Water Reactor Illdg.

60' A

No No 106SS213 59' A

No No 106SS214 60' A

No No 21121-19SSl90 Steam Relief Discharge Drywell 42' 1

No No 19SS192 43' I

No No 19SS193 44' I

No No 19SS194 37' I

No No 19SS195 37' I

No No w2 19SS196 32' I

No No 19SS198 18' 1

No No y

d, 19SSl99 18' 1

No No 26SS201 42' i

No No 26SS203 36' I

No No 26JS204 36' I

No No 26SS. %

18' i

No No 26SS207 18' I

No No 26SS208 11' I

No No 18SS211 42' I

No No N

18SS212 37' I

No No N

18SS21.1 37' 1

No No

~

e 18SS215 18' i

No No

'18SS216 17' i

No No 18SS218 5'

1 No No IISS220 g

38' I

No No 1ISS221 37' I

No No 1iSS222 36' i

No No

T_Alli.E 3._7. 5-1 en

o h

SAltit.TY llEl.ATEI) llYDitAlli.lC SNUllllEltS0 s:

5 lilGli ll.SI'EC I AI.l.Y SNilllllElt ACCESSIIll.E Olt itADiATION 1)] FI'l Clllir h

NO.

SYSTEtt LOCATION El.EVATION I NACCESS illi.E ZONIO'

  • TO itEllOVE H

(A or 1)

(Yes or No)

(Yes or No) ra 2il21-ilSS223 Steam itelief Discliarge 34' i

No No llSS224 34' i

No No 33SS245 43' I

No No 33SS246 43' i

No No 33SS248 45' i

No No 33SS249 36' I

No No 33SS250 36' I

No No 33SS251 32' I

No No w) 20SS256 44' I

No No 20SS25/

37' I

No No y

d, 20SS258 36' i

No No u

20SS260 18' i

No No 20SS261 20' I

No No 20SS262 IS' I

No No 27SS264 10' I

No No 2/SS266 17' I

No No 27SS267 18' 1

No No 2/SS269 36' I

No No N

27SS270 44' I

N<-

No 27SS272 42' i

No No 58SS275 18' i

No No 58SS276 30' i

No No CD 58hS277 31' 1

No No 58SS279 36' i

No No 58SS280 37' i

No No SMSS281 38' I

No No

TA_llt..E 3.1. 5-I en E

- _ Dita _lli.l.C_ SNili._lllE_ltSI' S A. l'_E_TY_ I(EI.A_TE.I_)

IlY vig 5

W i

ll1 Gil ESPEC I AI.I.Y SNUllllElt ACCESSllll.E Olt itAlll ATION D i l'l'I Clllll' g

a

~~-~~~

SYSTEM 1.0 CATION El.EVATION I N ACCESS illi.E ZONEf-TO ret 10VE NO.

s

- (A or I)

(Yes or No)

(ies or No) w 21121-12SS286 SLeam ite1iei D i sclia rge 39' 1

No No 12SS287 39' I

No No 12SS288 44' I

No No 12SS289 39' I

No No 12SS290 43' I

No No 12SS292 42' l

No No 34SS296 35' I

No No 34SS297 35' I

No No u3 34SS298 44' i

No No 34SS299 39' I

No No y

d, 34SS300 44' I

..o No 26SS302 11' 1

No No 26SS303 5'

I No No 58SS104 10' i

No No 58SS305 S'

i No No 58SS306 15' I

No No 58SS307 16' I

No No 12SS308 28' I

No No 12SS309 29' I

No No

~

12SS310 17' I

No No N

12SS311 11' i

No No 12SS312 11' I

No No lISS313 16' i

No No IISS314 11' I

No No llSS315 7'

I No No CD 19SS316 11' i

No No

TAlti.E 3. 7_. 5_ _1 en g

E cn SAFETY ltEl.ATED llVDRAlli.iC SNbilllEltS*

1

>-4 O

lil Gil ESPECI Al.l.Y g

SNilititElf ACCESSilli.E OR HAulATION DI FFI Clll/I' A

NO.

SYSTEtt 1.0 CATION El.EVATION I NACCESS illi.E ZON ES-*

TO ltEtt0VE d

(A or I)

(Yes or No)

'(Yes or No) ra 2il21-19SS317 Steam Reliel Discharge 17' i

No No 18SS318 1l' i

No No 20SS319 10' 1

No No 59SS320 11' i

No No S9SS325 34' I

No No 59SS326 35' I

No No 59SS32/

36' i

No No 59SS329 38' i

No No s

59SS330 44' I

No No 33SS332 26' I

No No Y

lISS333 7'

i No No U

3ISS334 11' 1

No No 3ISS335 19' i

No No 34SS336 27' I

No No 34SS337 18' i

No No 34SS338 18' i

No No

't4SS339 11' 1

No No 34SS340 7'

l No No N..

/-

Snubbers may be added to safety related systems without prior I.icense Amendment to Table 3.7.5-1 provided that safety evaluations, documentation and reporting are provided in accordance with 10 CFR 50.59 and that a proposed revision to Table 3.7.5-1 is included with the next License Amendment request.

I '- Modifications to this table due to changes in high radiation areas shall be submitted to the NRC as part of the next I.icense Amendment request.