  1. ,. e Rta

/, ; Q v

'o, UNITED STATES t

E

.c (g,~,g NUCLEAT: REGULATORY COMMISSION REGION V 5 Jj w?h [; *,F o,, 'M ;

1990 N. CALIFORNI A BOULEVARD f

%'4/

g' SUITE 202, WALNUT CREE K PLAZA

  • .,,e WALNUT CREE K, CALIFORNI A 94596 October 1,1979 Docket Nos. 50-206 50-361 50-362 Southern California Edison Company P. O. Box B00 2244 Walnut Grove Avenue Roser.1ead, California 91770 Attention:

Mr. A. Arenal, Vice President Advanced Engineering Gentlemen:

The enclosed Information Notice provides information with regard to an analysis that identifies an event that could result in overpressurization of containment at a pressurized water reactor.

Sincerely,

'l

/h,'61 ai-3 R. H. Engelken Director

Enclosures:

1.

Information Notice 79-24 2.

List of IE Information Notices Issued in the Last Six Months cc w/ enclosures:

J. M. C.rran, SCL J. T. Head, SCE J. H. Drake, SCE 1187 025 7910190

SSINS:

6E,7 Accession fio:

7908220123 UNITED STATES h/hlfy

[Jp r flUCLEAR P,EGULATORY COMMISSION Gdj/ h/d 0FFICE OF INSPECTION AND Ef!FORCEMENT Mu WASHIriGTON, D. C.

20555 October 1, 1979 IE Information flotice No. 79-24 OVERPRESSURIZATION OF CONTAINMENT OF A PWP, PLA!1T AFTER A MAIN STEAM LINE BREAK Virginia Electric and Power Co. submitted a report dated September 7,1979 that identied a deficiency in the original analyses of containment pressurization as a result of a steam line break for fiorth Anr.a Power Station, Units 3 and 4.

Stone and Webster Engineering Corporation performed a reanalyses of containment pressure following a main steam line break and determined that. if the auxiliary feedwater system continued to supply feedwater at runout conditions to the steam generator that had experienced the steam line break, containment design pressure would be exceeded in approximately 10 minutes.

The long term t' lowdown of the water supplied under runout conditions by the auxiliary feedwater system had not been considered in the earlier analyses.

The corrective action is now under review by the owner, arci.

';t engineer, and NSSS supplier.

This Information flotice is provided as an early notification of a possibly significant matter that is still under review by the flRC staff.

It is expected that recipients will review the information for possible applicability to their facilities.

fio specific action or response is requested at this time.

If NRC evaluations so indicate, further licensee actions may.;e requested or required.

fio written response to this Information flotice is required.

If you have any questions regarding this matter please contact the Director of tM appropriate l'.RC Regional Office.

1187 026

IE Information Notice No. 79-24 Enclosure October 1, 1979 Page 1 of 2 3

LISTING OF IE INFORMATION NOTICES ISSUED IN LAST SIX MONTHS Information Subject Date Issued To Notice No.

Issued 79 'O Nonconforming Pina 4/16/79 All power reactor Support Struts facilities with a CP 79-11 Lower Reactor Vessel Head 5/7/79 All holders of Reactor Insulation Support Probica OLs and cps 79-12 Attempted Damage to New 5/11/79 All Fuel Facilities Fuel Assemblies Research Reactors, and Power Reactors with an OL or CP 79-13 Indication of Low Mater 5/29/79 All Holders of Reactor Level in the Oyster Creek OLs and cps Reactor 79-14 NRC Position of Electrical 6/11/79 All Power Reactor Cable Support Systems Facilities with a CP 79-15 Deficient Procedures 6/7/79 All Holders of Reactor OLs and cps 79-16 Nuclear Incident at Three 6/22/79 All Research Reactors Mile Island and Test Reactors with OLs 79-17 Source Holder Assembly Damage 6/20/79 All Holders of Reactor Damage From Misfit Between Ols and cps Assembly and Reactor Upper Grid Plate 79-18 Skylab Reentry 7/5/79 All Holders of Reactor OLs 79-19 Pipe Cracks In Stagnant 7/17/79 All Holders of Reactor Borated Water Systems At OLs and cps PWR Plants 1181 027

IE Information Notice No. 79-24 Enclosure October 1,1979 Page 2 of 2 LISTING OF IE INFORMATION NOTICES ISSUED IN 1979 Information Subject Date Issued To Notice No.

Issued 79-20 NRC Enforcement Policy 8/10/79 All Holders of Reactor NRC Licensed Individuals OLs and cps and Production Licensees with Licensed Operators 79-21 Transportation and Commercial 9/7/79 All power and research Burial of Radioactive Material reactors with OL's 79-22 Qualification of Cantrol 9/14/79 All power reactor Systems facilities with operating licenses and construction permits.

79-23 Energency Diesel Generator 9/26/79 All Power facilities Lube Oil Coolers holding OLs and cps 11857 028