Interim Deficiency Rept Re Safety Injection Sys Piping. Weld Between Sump Liner & Process Pipe Found Insufficient to Carry Design Loads During Routine Design Review.Design Investigation Underway to Correct Problem
ML19210D643
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 11/21/1979
From:
HOUSTON LIGHTING & POWER CO.
To:
Shared Package
ML19210D635 List:
References
NUDOCS 7911270421
Download: ML19210D643 (5)


Text

. .

Page 1 of 2

- INTERIM REPORT -

SAFETY INJECTION SYSTEM PIPING DEFICIENCY November 21, 1979 I. SUIDIARY During a routine design review, a design deficiency was discov-ered in a Safety Injection System (SIS)/ Containment Spray System (CSS) containment emergency sumn piping design. The weld between the sump liner and the i.ecess pipe was not -

sufficient to carry the design loads. If left uncorrected, a failure of the weld joint would create stresses in the associ-ated recirculation valve that would exceed the design criteria.

Failure of this valve to open would prevent the SIS / CSS from performing its intended ianction of mitigating the consequences of an accident. A design investigation is underway to deter-mine the options acailable to correct this design deficiency.

An investigation s also underway to determine if this occurrence is indicative of a deficiency in the design control system or was the result of an isolated inciden:.

II. DESCRIPTION OF THE INCIDENT During a routine review, a design deficiency was discovered which, if left uncorrected, could have adversely affected the safety of operations. The joint between the 16 inch Safety Injection System piping and the emergency sump liner was shown on the construction drawing to be a one quarter inch seal weld, which does not meet the design load criteria. The location of this weld is shown in Figure 1.

The piping is part of the SIS and CSS and leads from the containment emergency sump through the containment sump isola-tion valve to the cafety injection and containment spray pumps. Following a LOCA, water will automatically be recircu-lated from the emergency sumps to the reactor by the Safety Injection System. Operation of the containment emergency sump isolation valve is required for recirculation mode operations.

The seal weld in question attaches the process pipe to the sump liner. Sketches of this configuration are given in Figures 1 and 2.

iT98 283 7911270 M [

Page 2 of 2 III. CORRECTIVE ACTION When this deficiency was discovered, the Engineer who identified the problem reported it on an Engineering Design Deficiency Report, as required by Engineering procedures. An investiga-tion into corrective actions and recurrence control was begun.

Resolution of this problem will consider the following:

Recirculation valve end loads Containment liner load limits -

Safety injection pump nozzle loads Sump liner load limits Containment sleeve load limits Differential settlement criteria Investigation of design alternatives has begun. A schedule for these activities is contained in Figure 3.

An investigation into the cause of this deficiency is also unde rway. This investigation will include an evaluation of the implementation, adequacy and effectiveness of project procedures relative to design control and design verification.

IV. SAFETY ANALYSIS If this deficiency were to have been left uncorrected, the weld at the sump liner / process pipe interface could fail. The process pipe would then be free of restraint and would impose a load on the recirculation valve which exceeds the allowable end loads. It could not then be guaranteed that the valve would operate as required. Because this problem affects all three trains, this is a common mode failure which could cause loss of safety system functions.

V. CONCLUSION Determination of the most appropriate correction for this deficiency is dependent upon completion of the investigation ,

of the cause(s) of the deficiency and evaluation of corrective action alternatives. A complete description of the cause(s),

corrective action, and recurrence control will be provided in a final report on March 23, 1980. .

1798 284

e ,

l l D SAFETY INJECTION SYSTEM RECIRCULATION LINE

,::,

i c%") e  %

,. J 6 i.

. rs= l ;g.p3 /  :;,

N - '

n-en M OutET10N&BLE / ,N j . ,, ,

E"% y

, N, F

[

'N g M* DU ARD

  • g " Cotti A.Nu r NT

%' N 5 ,[ PtNETRATiON I, E, ", I,g"g" '

f 8LfIVI I

=

j QUESTION ASLE /

f~. '% ~,

( ,, Ns .,1 n 4' M* CONT AthWENT . 's \ *I tuthothCY

~

S + g N SOMP *#, $

Pt h ETm & TION survt g g

's Ss Paocras umra ,

k , Sy ( .,

CD amutNT q N'.'N 7s N g

P1PE 00NT AJWW ENT

t. u .. . ,. - N, BUILDmG

..., ~. 'g~ .

's

'N, ' N s,

u LD Gw N 's

\

s \

e L

' a m

fai#"?;:a

Q$. , -

cl.cy' E

j\

e t

,~~g, l '. '

//

I \ /,

n ee.cuarton-vatva i l as i

.~. &

y .* O9j&ON N

GN

.O , _

..T 0 N ~.

1798 283 FIGURE 1 PIPING LAYOUT

g

. 2 3 . . . i *

. .k..s , , ,it

. .n ...a. .

g

' -.'.'ec','t.'c~.'

6)

~

.e.I

> .....o.

>;e,.....

. G

(<

0 9

_ma., . .u _ . . - Wao) tse.

D 11a'- --

C0,<"'.***'t"'

i 3 ..*

=

,6--

r

'" 1, e

CO 9

. . i ,

IIDW IMO ~

  • 11 W. j 6 kM2 +==== E W

?!M =a .

, m =-== c /; dw4 1 ENL ARGE0 SECTION THRU $UuP

  • a-h_.] 9 6

[ 1-g c

  • ek

/ 4} -s g_

.. .c._/

}! O "~

i:

cr- =."

} s e y ca ,.,5

_.L ,_ 7 _

3__ ,

.,m . .o. /

U. hs i..ctomi

... .e, T  ;

T,i.l Eum

, - -h _: ,4h b ,

' ~

. SOUTH TEXAS PROJECT j -

g er,0y ... UNITS 1 & 2 y AaRANGEMENT OF SUNP Pl#1NG A AND VALVE I5OLATION 1ANC i

rs.)

@ FIGURE 6.2.4-2  ;

O 4 5 8 F 2 3 FIGURE 2 SYSTEM SCHEMATIC DIAGRAM

1979 1980 ,s NOV DEC JAN FEB MAR 11 18 25 0310l1724 31 07 14 21 28 04 11 10 25 03 10 17 31 s ao N

RECURRANCE CONTROL - CO REVIEW OF DOCUMENTS Q Qs [

PERSONNEL INTERVIEWS C FINAL ASSEISMENT ,

MANAGEMENT RECOMMENDATIONS ---------~~1 I

I CORRECTIVE ACTION l DETERf11NE & EVALUATE OPTIONS C SELECT FINAL DESIGN RFVIFr! ann APPanvF. f FINAL REPORT RECURRANCE CONTROL '

IMPLEMENT CORRECTIVE ACTION O MILESTONE b DECISION FIGURE 3. SCHEDULE FOR THE COMPLETION OF ACTIVITIES 4

6