MONTHYEARML19029A1112019-01-29029 January 2019 Notice of Partially Closed Meeting with Hotec International, Inc. to Discuss the New Design for the Model No. HI-STAR Atb 1T Package Project stage: Meeting ML19098A1792019-03-19019 March 2019 Enclosure 2: Presentation HI-STAR Atb 1T Type B(U) Transportation Package: Revised Design to Meet 10 CFR 71 Acceptance Criteria (Memorandum to C. Regan Summary of March 19, 2019 Meeting with Holtec International) Project stage: Meeting ML19098A1772019-03-19019 March 2019, 8 April 2019 Package: Summary of March 19, 2019, Meeting with Holtec International Project stage: Request ML19098A1782019-04-0808 April 2019 Memorandum to C. Regan Summary of March 19, 2019 Meeting with Holtec International (W/Enclosure 1) Project stage: Meeting ML19158A5162019-06-0707 June 2019 Holtecs Proposed Certificate of Compliance (No. 9375) for the HI-STAR Atb 1T Package Project stage: Other ML19158A5172019-06-0707 June 2019 Responses to NRC Second Request for Additional Information (Rais) Project stage: Request ML19158A5292019-06-0707 June 2019 International - Affidavit Project stage: Other ML19158A5152019-06-0707 June 2019 Application for a Certificate of Compliance (CoC) for Holtecs Model No. Histar Atb 1T Type B(U)-96 Transportation Package Project stage: Request ML19158A5182019-06-0707 June 2019 HI-STAR Atb 1T Safety Analysis Report (Sar), HI-2146312, Revision 2 Project stage: Other ML19198A0272019-07-15015 July 2019 Letter to R. Ngwayah Request for Supplemental Information for the Review of the Model No. HI-STAR Atb 1T Package Project stage: Approval ML19198A0252019-07-15015 July 2019 Request for Supplemental Information for the Review of the Model No. HI-STAR Atb 1T Package Project stage: Request ML19198A0262019-07-15015 July 2019 Enclosurequest for Supplemental Information (Letter to R. Ngwayah Request for Supplemental Information for the Review of the Model No. HI-STAR Atb 1T Package) Project stage: Approval ML19221B4252019-08-0909 August 2019 Enclosure 1: Holtecs Responses to Questions in Rsis Letter Project stage: Other ML19221B4242019-08-0909 August 2019 International - Submittal of HI-STAR Atb 1T Application Rsis Responses Project stage: Other ML19316A1592019-11-0808 November 2019 Request for Additional Information for the Review of the Mode No. HI-Star Atb 1T Package Project stage: RAI ML20174A4972020-06-22022 June 2020 International, Affidavit Pursuant to 10 CFR 2.390 for Kimberly Manzione Project stage: Other ML20174A4872020-06-22022 June 2020 International, HI-STAR Atb 1T Safety Analysis Report (Sar), HI-2146312, Proposed Revision 3 Project stage: Other ML20174A4862020-06-22022 June 2020 International, Revised Proposed Certificate of Compliance (No. 9375) for HI-STAR Atb 1T Project stage: Other ML20174A4852020-06-22022 June 2020 International, Response to Request for Additional Information Project stage: Response to RAI ML20174A4842020-06-22022 June 2020 International, Submittal of Responses to Request for Additional Information for the Review of the Model No. HI-STAR Atb 1T Package Application Project stage: Response to RAI ML21124A2082021-05-0303 May 2021 International - Affidavit for Kimberly Manzione Project stage: Other ML21124A2052021-05-0404 May 2021 International - Submittal of the HI-STAR Atb 1T Safety Analysis Report Revision 3 Project stage: Other ML21124A2072021-05-0404 May 2021 HI-2146312, Revision 3, Safety Analysis Report on the HI-STAR Atb 1T Non-Fuel Waste Transport System Project stage: Other ML21172A2002021-06-28028 June 2021 Certificate of Compliance No. 9375, Revision No. 0, for the Model No. HI-STAR Atb 1T Package & Encl 2: Safety Evaluation Report Project stage: Approval ML21172A2012021-06-28028 June 2021 Encl 1: Certificate of Compliance No. 93175 Rev. 0 Project stage: Other 2019-07-15
[Table View] |
Text
Enclosure Request for Supplemental Information Holtec International Docket No. 71-9375 Model No. HI-STAR ATB 1T Package By letter dated June 7, 2019, Holtec International (Holtec) submitted an application for Certificate of Compliance No. 9375, Revision No. 0, for the Model No. HI-STAR ATB 1T package.
This request for supplemental information (RSI) identifies information needed by the U.S.
Nuclear Regulatory Commission staff (the staff) in connection with its acceptance review of the Model No. HI-STAR ATB 1T package application to confirm whether the applicant has submitted a complete application in compliance with regulatory requirements.
NUREG-1609, Standard Review Plan for Transportation Packages for Radioactive Material, was used for this review.
Chapter 2 - Structural Evaluation Provide animation and analysis files for the remaining portion of the 30 ft HAC (oblique) drop and several other drop simulations.
The applicant has provided a partial submission of the 30 ft HAC oblique drop scenario results generated by LS-DYNA. Specifically, the results from the 30 ft HAC (oblique) drop scenario appear to correspond to a drop progression that has not fully terminated (results are truncated at 0.06049 seconds (frame 244)), which indicate that the cask has not made complete contact with the target.
Provide and/or update the results in the SAR that correspond to a complete 30 ft HAC (oblique) drop.
In addition, the following files are requested:
- The input files used to generate the 1 ft NCT drop (top end).
- Output files for the 30 ft C1 sensitivity analysis This information is needed by the staff to determine compliance with Title 10 of the Code of Federal Regulations (10 CFR) 71.71(c)(7) and 71.73(c)(1).
OBSERVATION Justify the parameters used to model the targets concrete in LS-DYNA for the 1/4-scale prototype drop simulation.
2 MAT_PSEUDO_TENSOR (*MAT_016), used to represent the concrete portion of the target, incorporates values of the Lawrence Livermore National Laboratories (LLNL) target (as reported in UCRL-ID-126295) which has different concrete compressive strength and target characteristics than those of the Sandia National Laboratories (SNL) target that was effectively used for the 1/4 scale drop tests.
The applicant has not demonstrated that the LS-DYNA model used to represent the target at LLNL is representative of the one used at SNL. The applicant has also not justified the values of the parameters used in the *MAT_016 material card, such as cohesion, pressure hardening coefficients, effective plastic strain coefficients, yield stress values, etc.
The staff notes that the applicant was reminded of this concern, during the August 24, 2018, pre-application meeting. The publicly available meeting summary (Agencywide Documents Access and Management System Accession Number ML18256A100) notes that the applicant shall provide additional information on the derivation of properties based on those of the test site at SNL or perform a sensitivity analysis for the variation of the concrete parameters.
This information is needed by the staff to determine compliance with 10 CFR 71.71(c)(7), 71.73(c)(1), and 71.73(c)(3).