Letter Sequence Other |
|---|
EPID:L-2019-LRM-0006, Package: Summary of March 19, 2019, Meeting with Holtec International (Approved, Closed) |
Results
Other: ML19158A516, ML19158A518, ML19158A529, ML19221B424, ML19221B425, ML20174A486, ML20174A487, ML20174A497, ML21124A205, ML21124A207, ML21124A208, ML21172A201
|
MONTHYEARML19029A1112019-01-29029 January 2019 Notice of Partially Closed Meeting with Hotec International, Inc. to Discuss the New Design for the Model No. HI-STAR Atb 1T Package Project stage: Meeting ML19098A1792019-03-19019 March 2019 Enclosure 2: Presentation HI-STAR Atb 1T Type B(U) Transportation Package: Revised Design to Meet 10 CFR 71 Acceptance Criteria (Memorandum to C. Regan Summary of March 19, 2019 Meeting with Holtec International) Project stage: Meeting ML19098A1772019-03-19019 March 2019, 8 April 2019 Package: Summary of March 19, 2019, Meeting with Holtec International Project stage: Request ML19098A1782019-04-0808 April 2019 Memorandum to C. Regan Summary of March 19, 2019 Meeting with Holtec International (W/Enclosure 1) Project stage: Meeting ML19158A5162019-06-0707 June 2019 Holtecs Proposed Certificate of Compliance (No. 9375) for the HI-STAR Atb 1T Package Project stage: Other ML19158A5172019-06-0707 June 2019 Responses to NRC Second Request for Additional Information (Rais) Project stage: Request ML19158A5292019-06-0707 June 2019 International - Affidavit Project stage: Other ML19158A5152019-06-0707 June 2019 Application for a Certificate of Compliance (CoC) for Holtecs Model No. Histar Atb 1T Type B(U)-96 Transportation Package Project stage: Request ML19158A5182019-06-0707 June 2019 HI-STAR Atb 1T Safety Analysis Report (Sar), HI-2146312, Revision 2 Project stage: Other ML19198A0272019-07-15015 July 2019 Letter to R. Ngwayah Request for Supplemental Information for the Review of the Model No. HI-STAR Atb 1T Package Project stage: Approval ML19198A0252019-07-15015 July 2019 Request for Supplemental Information for the Review of the Model No. HI-STAR Atb 1T Package Project stage: Request ML19198A0262019-07-15015 July 2019 Enclosurequest for Supplemental Information (Letter to R. Ngwayah Request for Supplemental Information for the Review of the Model No. HI-STAR Atb 1T Package) Project stage: Approval ML19221B4252019-08-0909 August 2019 Enclosure 1: Holtecs Responses to Questions in Rsis Letter Project stage: Other ML19221B4242019-08-0909 August 2019 International - Submittal of HI-STAR Atb 1T Application Rsis Responses Project stage: Other ML19316A1592019-11-0808 November 2019 Request for Additional Information for the Review of the Mode No. HI-Star Atb 1T Package Project stage: RAI ML20174A4972020-06-22022 June 2020 International, Affidavit Pursuant to 10 CFR 2.390 for Kimberly Manzione Project stage: Other ML20174A4872020-06-22022 June 2020 International, HI-STAR Atb 1T Safety Analysis Report (Sar), HI-2146312, Proposed Revision 3 Project stage: Other ML20174A4862020-06-22022 June 2020 International, Revised Proposed Certificate of Compliance (No. 9375) for HI-STAR Atb 1T Project stage: Other ML20174A4852020-06-22022 June 2020 International, Response to Request for Additional Information Project stage: Response to RAI ML20174A4842020-06-22022 June 2020 International, Submittal of Responses to Request for Additional Information for the Review of the Model No. HI-STAR Atb 1T Package Application Project stage: Response to RAI ML21124A2082021-05-0303 May 2021 International - Affidavit for Kimberly Manzione Project stage: Other ML21124A2052021-05-0404 May 2021 International - Submittal of the HI-STAR Atb 1T Safety Analysis Report Revision 3 Project stage: Other ML21124A2072021-05-0404 May 2021 HI-2146312, Revision 3, Safety Analysis Report on the HI-STAR Atb 1T Non-Fuel Waste Transport System Project stage: Other ML21172A2002021-06-28028 June 2021 Certificate of Compliance No. 9375, Revision No. 0, for the Model No. HI-STAR Atb 1T Package & Encl 2: Safety Evaluation Report Project stage: Approval ML21172A2012021-06-28028 June 2021 Encl 1: Certificate of Compliance No. 93175 Rev. 0 Project stage: Other 2019-07-15
[Table View] |
Text
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Doc. I.D.: 2404018-NRC Page 1 of 2 May 4, 2021 Pierre Saverot - Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: USNRC Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No.:
71-9375 EPID.: L-2019-LRM-0006
Subject:
Submittal of the HI-STAR ATB 1T Safety Analysis Report Revision 3
Reference:
[1] Holtec Responses to HI-STAR ATB 1T Second Requests for Additional Information, Holtec Letter 2404017-NRC from Christopher OMullane (Holtec) to Pierre Saverot (NRC), dated April 20, 2021.
Dear Mr. Saverot,
By letter dated April 20, 2021 [1], Holtec submitted final responses to the Nuclear Regulatory Commissions (NRC) second round requests for additional information pertaining to the HI-STAR ATB 1T application, along with the proposed Certificate of Compliance (CoC) and supporting licensing drawings and technical reports. To accompany this submittal, Holtec herewith submits Revision 3 of the Safety Analysis Report (SAR) for the HI-STAR ATB 1T Non-Fuel Waste Transport System (Holtec Report HI-2146312).
of this letter contains the proprietary version of the abovementioned SAR, while contains the non-proprietary version. As Attachment 1 is considered proprietary, an affidavit requesting that the information therein be withheld from public disclosure in accordance with 10 CFR 2.390 is contained in Attachment 3.
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Doc. I.D.: 2404018-NRC Page 2 of 2 If you have any questions, please contact me at:
Email: c.omullane@holtec.com Office: 856-797-0900 Ext. 3848 Cell: 856-912-1162 Sincerely, Christopher OMullane Licensing Engineer Holtec International cc:
(letter only w/o attachments via email)
John McKirgan (USNRC)
Kimberly Manzione (Holtec)
Attachments Holtec Report HI-2146312, Safety Analysis Report on the HI-STAR ATB 1T Non-Fuel Waste Transport System, Revision 3 (PROPRIETARY) :
Holtec Report HI-2146312, Safety Analysis Report on the HI-STAR ATB 1T Non-Fuel Waste Transport System, Revision 3 (NON-PROPRIETARY) :
Affidavit in Accordance with 10 CFR 2.390