MONTHYEARML17356A2542017-05-25025 May 2017 Trip Report for May 16 to May 18, 2017, Audit in Support of the Review of Topical Report ANP-10332P (AURORA-B LOCA) (Non-Proprietary Version) Project stage: Other ML17356A2372017-05-25025 May 2017, 10 January 2018 Audit Report for the May 16 to May 18, 2017 Audit in Support of the Review of ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-proprietary Version) Project stage: Request ML19095B7672017-10-24024 October 2017 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 1, Non-Proprietary) Project stage: RAI ML17356A2502018-01-10010 January 2018 NRC Staff Post-Acceptance Review Feedback and Questions, Areva'S Response Approach, and Subsequent NRC Staff Audit Comments for May 16 to May 18, 2017 Audit Supporting the Review of ANP-10332P (AURORA-B LOCA) Project stage: Acceptance Review ML17356A2472018-01-10010 January 2018 Audit Report for the May 16 to May 18, 2017 Audit in Support of the Review of ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietary Version) Project stage: Approval ML17356A2432018-01-10010 January 2018 Transmittal of Audit Report for the May 16 to May 18, 2017 Audit in Support of the Review of ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietar Project stage: Approval ML17360A2072018-01-19019 January 2018 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: RAI ML19095B7692018-01-19019 January 2018 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2) Project stage: Request ML19095B7702018-01-19019 January 2018 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2, Non-Proprietar Project stage: RAI ML19095B7732018-01-19019 January 2018 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2, Non-Proprietary) Project stage: RAI ML18171A3082018-07-17017 July 2018 Request for Withholding Information from Public Disclosure in April 30, 2018, Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0 (CAC No. MF3829; EPID L-2014-TOP-0004) Project stage: RAI ML18242A4262018-08-31031 August 2018 Draft Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios, (Non-Proprietary) Project stage: Draft Approval ML18323A5592018-12-18018 December 2018 Request for Withholding Information from Public Disclosure in October 31, 2018, Revised Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0 Project stage: RAI ML19052A5722019-03-26026 March 2019 Final Safety Evaluation for Framatome, Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietary Version) Project stage: Approval ML19057A5552019-03-26026 March 2019 Transmittal of Final Safety Evaluation for Framatome Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios. Project stage: Approval ML19057A5512019-03-26026 March 2019 Final Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Request ML19071A2952019-03-26026 March 2019 Resolution of Comments on Draft Safety Evaluation for Topical Report ANP-10332P, Revision 0 Project stage: Draft Approval ML19183A0102019-07-25025 July 2019 Verification Review Letter for Topical Report ANP-10332P-A, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Other 2018-12-18
[Table View] |
|
---|
Category:Acceptance Review Letter
MONTHYEARML20049H7052020-02-0707 February 2020 Acceptance for Review of BAW-10227P, Revision 2 (Email) ML19240A9562019-09-12012 September 2019 Verification Letter for Topical Report EMF-93-177, Revision 1, Supplement 2P-A, Revision 1 ML19232A0832019-09-0505 September 2019 Verification Letter of the Approval Version of Framatome Inc. Topical Report Baw 10227, Revision 1, Supplement 1P-A, Revision 0 Evaluation of Advanced Cladding and Structural Material (M5) in PWR Reactor Fuel (CAC MF9716/EPID L-2017-TOP-003 ML19183A0102019-07-25025 July 2019 Verification Review Letter for Topical Report ANP-10332P-A, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios ML18345A1592018-12-18018 December 2018 Acceptance Letter for Review of Topical Report ANP-10339P, Arita -AREMIS/RELAP Integrated Transient Analysis Methodology ML18325A1932018-12-0606 December 2018 Acceptance for Review of Framatome Inc. Topical Report ANP-10337, Revision 0, Supplement 1P, Revision 0, Deformable Spacer Grid Element ML18285A4242018-11-0707 November 2018 Verification Letter of the Approval Version of Framatome Inc. Topical Report ANP-10297, Revision 0, Supplement 1P-A, Revision 0, the Arcadia Reactor Analysis System for PWRs Methodology Description and Benchmarking Results ML18284A2572018-11-0707 November 2018 Acceptance for Review of Framatome Inc. Topical Report EMF 93-177, Revision 1, Supplement 2P, Revision 1, Mechanical Design for BWR Fuel Channels: Z4B Material ML18254A2452018-09-24024 September 2018 Verification of the Approval Version of Topical Report BAW-10247P-A, Supplement 2P-A, Revision 0, Realistic Thermal-Mechanical Fuel Rod Methodology for Boiling Water Reactors Supplement 2: Mechanical Methods ML18249A3942018-09-24024 September 2018 Verification of Topical Report ANP-10333P-A, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Control Rod Drop Accident (CRDA) ML18059A9542018-03-13013 March 2018 Acceptance Review Letter for Framatome Topical Report ANP-10346P, Revision 0, ATWS-I Analysis Methodology for BWRs Using RAMONA5-FA 2020-02-07
[Table view] |
Text
July 25, 2019 Mr. Gary Peters, Director Licensing and Regulatory Affairs Framatome Inc.
3315 Old Forest Road Lynchburg, VA 24501
SUBJECT:
VERIFICATION LETTER OF THE APPROVAL VERSION OF FRAMATOME INC.
TOPICAL REPORT ANP-10332P-A, REVISION 0, "AURORA-B: AN EVALUATION MODEL FOR BOILING WATER REACTORS; APPLICATION TO LOSS OF COOLANT ACCIDENT SCENARIOS" (CAC NO. MF3829/
EPID: L-2014-TOP-0004)
Dear Mr. Peters:
By letter dated June 7, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19163A226), Framatome Inc. (Framatome, formerly AREVA Inc.)
submitted an approval (-A) version of Topical Report (TR) ANP-10332P-A, Revision 0, "AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios," to the U.S. Nuclear Regulatory Commission (NRC) staff. Framatome has done so in accordance with our request to publish approval proprietary and non-proprietary versions of this TR, as detailed in the transmittal letter dated March 26, 2019, of the NRC staffs final safety evaluation (ADAMS Accession No. ML19057A555) for the original TR.
The NRC staff has completed its review of the approval version of the TR. The NRC staff verified that Framatome has met the requirements and determined that the submitted -A versions are acceptable for referencing in licensing applications for nuclear power plants to the extent specified and under the limitations delineated in the accepted versions of the TR. TR ANP-10332P-A, Revision 0, "AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios, is now approved for use in future licensing actions.
Please contact Jonathan G. Rowley of my staff at (301) 415-4053 if you have on questions on this subject.
Sincerely,
/RA/
Dennis C. Morey, Chief Licensing Processes Branch Division of Licensing Projects Office of Nuclear Reactor Regulation Docket No. 99902041
ML19183A010; *concurrence via e-mail NRR-106 OFFICE NRR/DLP/PLPB NRR/DLP/PLPB* NRR/DSS/SNPB NRR/DLP/PLPB NAME JRowley DHarrison RLukes DMorey DATE 07/02/2019 07/09/2019 07/24/2019 07/25/2019