Letter Sequence Draft Approval |
|---|
CAC:MF3829, (Approved, Closed) EPID:L-2014-TOP-0004, Final Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Approved, Closed) |
|
MONTHYEARML17356A2372017-05-25025 May 2017, 10 January 2018 Audit Report for the May 16 to May 18, 2017 Audit in Support of the Review of ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-proprietary Version) Project stage: Request ML17356A2542017-05-25025 May 2017 Trip Report for May 16 to May 18, 2017, Audit in Support of the Review of Topical Report ANP-10332P (AURORA-B LOCA) (Non-Proprietary Version) Project stage: Other ML19095B7612017-10-24024 October 2017 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Request ML19095B7642017-10-24024 October 2017 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 1, Non-Proprietar Project stage: RAI ML19095B7672017-10-24024 October 2017 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 1, Non-Proprietary) Project stage: RAI ML17356A2502018-01-10010 January 2018 NRC Staff Post-Acceptance Review Feedback and Questions, Areva'S Response Approach, and Subsequent NRC Staff Audit Comments for May 16 to May 18, 2017 Audit Supporting the Review of ANP-10332P (AURORA-B LOCA) Project stage: Acceptance Review ML17356A2472018-01-10010 January 2018 Audit Report for the May 16 to May 18, 2017 Audit in Support of the Review of ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietary Version) Project stage: Approval ML17356A2432018-01-10010 January 2018 Transmittal of Audit Report for the May 16 to May 18, 2017 Audit in Support of the Review of ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietar Project stage: Approval ML19095B7692018-01-19019 January 2018 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2) Project stage: Request ML19095B7702018-01-19019 January 2018 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2, Non-Proprietar Project stage: RAI ML17360A2072018-01-19019 January 2018 Transmittal of Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: RAI ML19095B7732018-01-19019 January 2018 Request for Additional Information Regarding Areva Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Set 2, Non-Proprietary) Project stage: RAI ML18122A2302018-04-30030 April 2018 ANP-10332Q1NP, Rev 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Responses to NRC Request for Additional Information Project stage: Response to RAI ML18122A2292018-04-30030 April 2018 Framatome, Inc., Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0, AURORA-8: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Response to RAI ML18171A3082018-07-17017 July 2018 Request for Withholding Information from Public Disclosure in April 30, 2018, Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0 (CAC No. MF3829; EPID L-2014-TOP-0004) Project stage: RAI ML18242A4262018-08-31031 August 2018 Draft Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios, (Non-Proprietary) Project stage: Draft Approval ML18323A5592018-12-18018 December 2018 Request for Withholding Information from Public Disclosure in October 31, 2018, Revised Response to Request for Additional Information Regarding Topical Report ANP-10332P, Revision 0 Project stage: RAI ML19052A5722019-03-26026 March 2019 Final Safety Evaluation for Framatome, Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios (Non-Proprietary Version) Project stage: Approval ML19057A5552019-03-26026 March 2019 Transmittal of Final Safety Evaluation for Framatome Inc. Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios. Project stage: Approval ML19057A5512019-03-26026 March 2019 Final Safety Evaluation for Topical Report ANP-10332P, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Request ML19071A2952019-03-26026 March 2019 Resolution of Comments on Draft Safety Evaluation for Topical Report ANP-10332P, Revision 0 Project stage: Draft Approval ML19183A0102019-07-25025 July 2019 Verification Review Letter for Topical Report ANP-10332P-A, Revision 0, AURORA-B: an Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Project stage: Other 2018-12-18
[Table View] |
Text
RESOLUTION OF COMMENTS BY THE OFFICE OF NUCLEAR REACTOR REGULATION ON DRAFT SAFETY EVALUATION FOR TOPICAL REPORT ANP-10332P, REVISION 0, AURORA-B: AN EVALUATION MODEL FOR BOILING WATER REACTORS; APPLICATION TO LOSS OF COOLANT ACCIDENT SCENARIOS FRAMATOME, INC.
PROJECT NO. 728/DOCKET NO. 99902041 This attachment provides the U.S. Nuclear Regulatory Commission (NRC) staffs review and disposition of the comments made by Framatome Inc. on the draft safety evaluation (SE) for Topical Report ANP-10332P, Revision 0, AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios.
Reference 1: ANP-10332Q1P Revision 1, AURORA-B: An Evaluation Model for Boiling Water Reactors; Application to Loss of Coolant Accident Scenarios Response to NRC Request for Additional Information, October 2018 Draft ANP-10332Q1P Limitation Revision 1 Proposed NRC Resolution of Proposed (Reference 1) Change/Comment Change/Comment Condition RAI No.
(L&C) #
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #8. Text 8 20c revised RAI response in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #9. Text 9 114 revised RAI response in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #12.
12 13d revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #13.
13 46 revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
Attachment
Draft ANP-10332Q1P Limitation Revision 1 Proposed NRC Resolution of Proposed (Reference 1) Change/Comment Change/Comment Condition RAI No.
(L&C) #
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #16.
16 13c revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #17.
17 110b revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #22.
22 29e revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #23.
23 33f revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #24.
24 35 revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #25.
25 29a revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #26.
26 29b revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
Draft ANP-10332Q1P Limitation Revision 1 Proposed NRC Resolution of Proposed (Reference 1) Change/Comment Change/Comment Condition RAI No.
(L&C) #
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #32.
32 105 revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
The NRC staff found the information in the RAI response Delete L&C based on sufficient to remove L&C #33.
33 106 revised RAI response Text in accompanying sections of the draft was modified accordingly in the final SE.
Framatome proposes to delete Section 12, Uses, Updates and Modifications from the The NRC staff accepts the topical report when the deletion of Section 12 from approved version is Topical Report ANP-10332, 40 N/A issued. This deletion Revision 0. Section 4.3, L&C #40, eliminates the need for and references to L&C #40 of the L&C 40 and most of draft was modified accordingly in the discussion in the final SE.
Section 4.3 of the SE, as well as references in the SE to L&C 40.